Neutron stimulated emission computed tomography: Difference between revisions
Citation bot (talk | contribs) Add: s2cid. | Use this bot. Report bugs. | Suggested by RoanokeVirginia | Category:Medical imaging | #UCB_Category 100/196 |
Citation bot (talk | contribs) Alter: title. Add: chapter. Removed parameters. | Use this bot. Report bugs. | #UCB_CommandLine |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Short description|Imaging technique using induced gamma rays}} |
|||
{{Orphan|date=September 2011}} |
|||
{{Infobox diagnostic |
{{Infobox diagnostic |
||
| name = Neutron stimulated emission computed tomography |
| name = Neutron stimulated emission computed tomography |
||
Line 22: | Line 22: | ||
| LOINC = <!--{{LOINC|code}}--> |
| LOINC = <!--{{LOINC|code}}--> |
||
}} |
}} |
||
'''Neutron stimulated emission computed tomography (NSECT)''' uses [[induced gamma emission]] through [[neutron]] [[inelastic scattering]] to generate [[image]]s of the [[spatial distribution]] of [[Chemical element|element]]s in a [[Sample (material)|sample]].<ref>{{cite book|last=Kapadia|first=Anuj|title=Neutron Stimulated Emission Computed Tomography: A |
'''Neutron stimulated emission computed tomography (NSECT)''' uses [[induced gamma emission]] through [[neutron]] [[inelastic scattering]] to generate [[image]]s of the [[spatial distribution]] of [[Chemical element|element]]s in a [[Sample (material)|sample]].<ref>{{cite book|last=Kapadia|first=Anuj|title=Neutron Imaging and Applications |chapter=Neutron Stimulated Emission Computed Tomography: A New Technique for Spectroscopic Medical Imaging |year=2009|pages=265–288|doi=10.1007/978-0-387-78693-3_15|series=Neutron Scattering Applications and Techniques|isbn=978-0-387-78692-6}}</ref> |
||
== Clinical Applications == |
== Clinical Applications == |
Latest revision as of 15:42, 27 August 2023
Neutron stimulated emission computed tomography | |
---|---|
Purpose | detecting liver iron overload disorders |
Neutron stimulated emission computed tomography (NSECT) uses induced gamma emission through neutron inelastic scattering to generate images of the spatial distribution of elements in a sample.[1]
Clinical Applications
[edit]NSECT has been shown to be effective in detecting liver iron overload disorders[2] and breast cancer.[3] Due to its sensitivity in measuring elemental concentrations, NSECT is currently being developed for cancer staging, among other medical applications.
NSECT mechanism
[edit]A given atomic nucleus, defined by its proton and neutron numbers, is a quantized system with a set of characteristic higher energy levels that it can occupy as a nuclear isomer. When the nucleus in its ground state is struck by a fast neutron with kinetic energy greater than that of its first excited state, it can undergo an isomeric transition to one of its excited states by receiving the necessary energy from the fast neutron through inelastic scatter. Promptly (on the order of picoseconds, on average) after excitation, the excited nuclear isomer de-excites (either directly or through a series of cascades) to the ground state, emitting a characteristic gamma ray for each decay transition with energy equal to the difference in the energy levels involved (see induced gamma emission). After irradiating the sample with neutrons, the measured number of emitted gamma rays of energy characteristic to the nucleus of interest is directly proportional to the number of such nuclei along the incident neutron beam trajectory. After repeating the measurement for neutron beam incidence at positions around the sample, an image of the distribution of the nuclei in the sample can be reconstructed as done in tomography.
References
[edit]- ^ Kapadia, Anuj (2009). "Neutron Stimulated Emission Computed Tomography: A New Technique for Spectroscopic Medical Imaging". Neutron Imaging and Applications. Neutron Scattering Applications and Techniques. pp. 265–288. doi:10.1007/978-0-387-78693-3_15. ISBN 978-0-387-78692-6.
- ^ Kapadia, Anuj (2007). Accuracy and patient dose in neutron stimulated emission computed tomography for diagnosis of iron overload: Simulations in GEANT4. Durham, NC: Duke University.
- ^ Kapadia, Anuj; Sharma, Amy C.; Georgia Tourassi; Bender, Janelle E.; Howell, Calvin R.; Crowell, Alexander S.; Kiser, Matthew R.; Harrawood, Brian P.; Pedroni, Ronald S.; Floyd Jr, Carey E. (2008). "Neutron Stimulated Emission Computed Tomography for Diagnosis of Breast Cancer". IEEE Transactions on Nuclear Science. 55 (1): 501–509. Bibcode:2008ITNS...55..501K. CiteSeerX 10.1.1.660.9231. doi:10.1109/TNS.2007.909847. S2CID 11928052.
Further reading
[edit]- NSECT at Ravin Advanced Imaging Laboratories, Duke University
- [1] Floyd CE, Bender JE, Sharma AC, Kapadia A, Xia J, and Harrawood B, Tourassi GD, Lo JY, Crowell A, and Howell C. "Introduction to neutron stimulated emission computed tomography," Physics in Medicine and Biology. 51:3375. 2006.
- [2] Sharma AC, Harrawood BP, Bender JE, Tourassi GD, and Kapadia AJ. "Neutron stimulated emission computed tomography: a Monte Carlo simulation approach,"Physics in Medicine and Biology. 52:6117. 2007.
- [3] Floyd CE, Kapadia, AJ, et al. "Neutron-stimulated emission computed tomography of a multi-element phantom," Physics in Medicine and Biology. 53:2313. 2008.