[[File:EVT4 i sonda.jpg|thumb|Electrical capacitance tomography system<ref>{{cite journal |last1=Wanta |first1=Damian |last2=Smolik |first2=Waldemar T. |last3=Kryszyn |first3=Jacek |last4=Wróblewski |first4=Przemysław |last5=Midura |first5=Mateusz |title=A Run-Time Reconfiguration Method for an FPGA-Based Electrical Capacitance Tomography System |journal=Electronics |volume=11 |issue=4 |date=2022 |page=545 |doi=10.3390/electronics11040545|doi-access=free }}</ref> with connected 16-electrode sensor]]
{{Citation style|date=November 2013}}
[[File:SondaFantom2D.gif|thumb|Dynamic imaging in process tomography - On the left, seven objects moving along the probe. On the right, a series of probe cross-sectional images]]

'''Process tomography'''<ref> York, T., 2001. Status of electrical tomography in industrial applications, Journal of Electronic Imaging</ref> consists of [[tomography|tomographic]] imaging of systems, such as process pipes in industry. In tomography the [[Three-dimensional space|3D]] distribution of some physical quantity in the object is determined. There is a widespread need to get tomographic information about process. This information can be used, for example, in the design and control of processes.<ref>{{cite journal
'''Process tomography'''<ref> York, T., 2001. Status of electrical tomography in industrial applications, Journal of Electronic Imaging</ref> consists of [[tomography|tomographic]] imaging of systems, such as process pipes in industry. In tomography the [[Three-dimensional space|3D]] distribution of some physical quantity in the object is determined. There is a widespread need to get tomographic information about process. This information can be used, for example, in the design and control of processes.
| title=Process Tomography: Principles, Techniques and Applications
<ref>{{cite journal | title=Process Tomography: Principles, Techniques and Applications | first= L. F. | last=Gladden | journal=Measurement Science and Technology | year=1997 | number=4 | volume=8 | url=http://stacks.iop.org/0957-0233/8/i=4/a=021 | doi=10.1088/0957-0233/8/4/021 | s2cid= 250815245 }} </ref>
| first= L. F.
| last=Gladden
| journal=Measurement Science and Technology
| year=1997
| number=4
| volume=8
| url=http://stacks.iop.org/0957-0233/8/i=4/a=021
| doi=10.1088/0957-0233/8/4/021
}}
</ref>


Tomography involves taking measurements around the periphery of an object (e.g. process vessel or patient) to determine what is going on inside.
Tomography involves taking measurements around the periphery of an object (e.g. process vessel or patient) to determine what is going on inside.
Line 19: Line 9:


Many different imaging methods are used in process tomography, e.g. [[Medical ultrasonography|ultrasonic imaging]], [[positron emission tomography]] (PET), [[electrical resistance tomography]] (ERT) and [[electrical impedance tomography]] (EIT), [[electrical capacitance tomography]] (ECT), [[magnetic induction tomography]] (MIT). In all cases external sensors are used to detect signals from boundary of the object, and the three-dimensional material distribution or the velocity field is computed using the measured data.
Many different imaging methods are used in process tomography, e.g. [[Medical ultrasonography|ultrasonic imaging]], [[positron emission tomography]] (PET), [[electrical resistance tomography]] (ERT) and [[electrical impedance tomography]] (EIT), [[electrical capacitance tomography]] (ECT), [[magnetic induction tomography]] (MIT). In all cases external sensors are used to detect signals from boundary of the object, and the three-dimensional material distribution or the velocity field is computed using the measured data.
{{Cite book |author1=Williams, R. A. |author2=Beck, M. S. | title=Process Tomography: Principles, Techniques, and Applications | publisher=Butterworth-Heinemann| year=1995| isbn=0750607440}}
Process tomography is an area of rapid growth both in terms of research and applications. There are number of challenges remaining in this area including data processing an image reconstruction,<ref>Soleimani, M., 2008. Computational aspects of low frequency electrical and electromagnetic tomography: A review study. International Journal of Numerical Analysis and Modeling, 5 (3), pp.&nbsp;407–440.</ref> and application of imaging modalities in a real applications.
Process tomography is an area of rapid growth both in terms of research and applications. There are number of challenges remaining in this area including data processing an image reconstruction,<ref>Soleimani, M., 2008. Computational aspects of low frequency electrical and electromagnetic tomography: A review study. International Journal of Numerical Analysis and Modeling, 5 (3), pp.&nbsp;407–440.</ref> and application of imaging modalities in a real applications.


==See also==
==See also==
* [[Electrical capacitance volume tomography]]
* [[Electrical impedance tomography]]
* [[Electrical impedance tomography]]
* [[Electrical resistivity tomography]]
* [[Electrical resistivity tomography]]
* [[Electrical capacitance tomography]]
* [[Electrical capacitance tomography]]
* [[Three-dimensional electrical capacitance tomography]]
* [[Industrial Tomography Systems]]
* [[Industrial Tomography Systems]]


== References ==
== References ==
{{Reflist}}
{{Reflist}}

* {{Cite book |author1=Williams, R. A. |author2=Beck, M. S. | title=Process Tomography: Principles, Techniques, and Applications | edition= | publisher=Butterworth-Heinemann| year=1995| ISBN=0750607440}}


== External links ==
== External links ==

* [http://www.isipt.org/ International Society for Industrial Process Tomography]
* [http://www.isipt.org/ International Society for Industrial Process Tomography]
* [http://www.itoms.com/ Industrial Tomography Systems]
* [http://www.itoms.com/ Industrial Tomography Systems]

Latest revision as of 23:18, 14 February 2024

Electrical capacitance tomography system[1] with connected 16-electrode sensor
Dynamic imaging in process tomography - On the left, seven objects moving along the probe. On the right, a series of probe cross-sectional images

Process tomography[2] consists of tomographic imaging of systems, such as process pipes in industry. In tomography the 3D distribution of some physical quantity in the object is determined. There is a widespread need to get tomographic information about process. This information can be used, for example, in the design and control of processes. [3]

Tomography involves taking measurements around the periphery of an object (e.g. process vessel or patient) to determine what is going on inside.

The best known technique is CT scanning in medicine; however, process tomography instrumentation needs to be cheaper, faster and more robust.

Many different imaging methods are used in process tomography, e.g. ultrasonic imaging, positron emission tomography (PET), electrical resistance tomography (ERT) and electrical impedance tomography (EIT), electrical capacitance tomography (ECT), magnetic induction tomography (MIT). In all cases external sensors are used to detect signals from boundary of the object, and the three-dimensional material distribution or the velocity field is computed using the measured data. Williams, R. A.; Beck, M. S. (1995). Process Tomography: Principles, Techniques, and Applications. Butterworth-Heinemann. ISBN 0750607440. Process tomography is an area of rapid growth both in terms of research and applications. There are number of challenges remaining in this area including data processing an image reconstruction,[4] and application of imaging modalities in a real applications.

See also

[edit]

References

[edit]
  1. ^ Wanta, Damian; Smolik, Waldemar T.; Kryszyn, Jacek; Wróblewski, Przemysław; Midura, Mateusz (2022). "A Run-Time Reconfiguration Method for an FPGA-Based Electrical Capacitance Tomography System". Electronics. 11 (4): 545. doi:10.3390/electronics11040545.
  2. ^ York, T., 2001. Status of electrical tomography in industrial applications, Journal of Electronic Imaging
  3. ^ Gladden, L. F. (1997). "Process Tomography: Principles, Techniques and Applications". Measurement Science and Technology. 8 (4). doi:10.1088/0957-0233/8/4/021. S2CID 250815245.
  4. ^ Soleimani, M., 2008. Computational aspects of low frequency electrical and electromagnetic tomography: A review study. International Journal of Numerical Analysis and Modeling, 5 (3), pp. 407–440.
[edit]