Jump to content

Quantitative phase-contrast microscopy: Difference between revisions

From Wikipedia, the free encyclopedia
Content deleted Content added
External links: Updated categories.
Reverting edit(s) by Rhubarb9 (talk) to rev. 1138627682 by Citation bot: Unexplained content removal (UV 0.1.5)
 
(7 intermediate revisions by 6 users not shown)
Line 21: Line 21:
| year=1999
| year=1999
| doi=10.1364/OL.24.000291|pmid=18071483 |bibcode = 1999OptL...24..291C }}</ref><ref>{{cite journal
| doi=10.1364/OL.24.000291|pmid=18071483 |bibcode = 1999OptL...24..291C }}</ref><ref>{{cite journal
| vauthors=Park Y, Depeursinge C, Popescu G
| vauthors=Park Y, Depeursinge C, [[Gabriel Popescu (scientist)|Popescu G]]
| title=Quantitative phase imaging in biomedicine
| title=Quantitative phase imaging in biomedicine
| journal=Nature Photonics
| journal=Nature Photonics
Line 30: Line 30:
| doi=10.1038/s41566-018-0253-x| pmid=<!--none-->
| doi=10.1038/s41566-018-0253-x| pmid=<!--none-->
| bibcode=2018NaPho..12..578P
| bibcode=2018NaPho..12..578P
| s2cid=256704142
}}</ref>
}}</ref>


Translucent objects, like a living human cell, absorb and scatter small amounts of light.
Translucent objects, like a living human cell, absorb and scatter small amounts of light.
This makes translucent objects difficult to observe in ordinary light microscopes.
This makes translucent objects much easier to observe in ordinary light microscopes.
Such objects do, however, induce a phase shift that can be observed using a [[phase contrast microscopy|phase contrast microscope]].
Such objects do, however, induce a phase shift that can be observed using a [[phase contrast microscopy|phase contrast microscope]].
Conventional phase contrast microscopy and related methods, such as [[differential interference contrast microscopy]], visualize phase shifts by transforming phase shift gradients into intensity variations.
Conventional phase contrast microscopy and related methods, such as [[differential interference contrast microscopy]], visualize phase shifts by transforming phase shift gradients into intensity variations.
Line 43: Line 44:
values in each pixel, as exemplified by Figure 1.
values in each pixel, as exemplified by Figure 1.


[[File:Phase shift image of cells in 3D.jpg|thumb| '''Figure 1''': In this phase shift image of cells in culture, the height and color of an image point correspond to the measured phase shift. The phase shift induced by an object in an image point depends only on the object's thickness and the relative [[refractive index]] of the object in the image point. The volume of an object can therefore be determined from a phase shift image when the difference in refractive index between the object and the surrounding media is known.<ref name="Kemmler">{{cite journal
[[File:Phase shift image of cells in 3D.jpg|thumb| '''Figure 1''': In this phase shift image of cells in culture, the height and color of an image point correspond to the measured phase shift. The phase shift induced by an object in an image point depends only on the object thickness and the relative [[refractive index]] of the object in the image point. The volume of an object can therefore be determined from a phase shift image when the difference in refractive index between the object and the surrounding media is known.<ref name="Kemmler">{{cite journal
| author=Manuel Kemmler |author2=Markus Fratz |author3=Dominik Giel |author4=Norbert Saum |author5=Albrecht Brandenburg |author6=Christian Hoffmann
| author=Manuel Kemmler |author2=Markus Fratz |author3=Dominik Giel |author4=Norbert Saum |author5=Albrecht Brandenburg |author6=Christian Hoffmann
| title=Noninvasive time-dependent cytometry monitoring by digital holography
| title=Noninvasive time-dependent cytometry monitoring by digital holography
Line 52: Line 53:
| year=2007
| year=2007
| doi=10.1117/1.2804926
| doi=10.1117/1.2804926
| pmid=18163818|bibcode = 2007JBO....12f4002K }}</ref>]]
| pmid=18163818|bibcode = 2007JBO....12f4002K |s2cid=40335328 | doi-access=free}}</ref>]]


The principal methods for measuring and visualizing phase shifts include [[ptychography]] and various types
The principal methods for measuring and visualizing phase shifts include [[ptychography]] and various types

Latest revision as of 17:45, 4 August 2024

Quantitative phase contrast microscope
AcronymQPCM, QPM, QPI
Other namesPhase microscope, Quantitative phase microscopy, Quantitative phase imaging
UsesMicroscopic observation and quantification of unstained biological material
Related itemsPhase contrast microscopy, Differential interference contrast microscopy, Hoffman modulation contrast microscopy

Quantitative phase contrast microscopy or quantitative phase imaging are the collective names for a group of microscopy methods that quantify the phase shift that occurs when light waves pass through a more optically dense object.[1][2]

Translucent objects, like a living human cell, absorb and scatter small amounts of light. This makes translucent objects much easier to observe in ordinary light microscopes. Such objects do, however, induce a phase shift that can be observed using a phase contrast microscope. Conventional phase contrast microscopy and related methods, such as differential interference contrast microscopy, visualize phase shifts by transforming phase shift gradients into intensity variations. These intensity variations are mixed with other intensity variations, making it difficult to extract quantitative information.

Quantitative phase contrast methods are distinguished from conventional phase contrast methods in that they create a second so-called phase shift image or phase image, independent of the intensity (bright field) image. Phase unwrapping methods are generally applied to the phase shift image to give absolute phase shift values in each pixel, as exemplified by Figure 1.

Figure 1: In this phase shift image of cells in culture, the height and color of an image point correspond to the measured phase shift. The phase shift induced by an object in an image point depends only on the object thickness and the relative refractive index of the object in the image point. The volume of an object can therefore be determined from a phase shift image when the difference in refractive index between the object and the surrounding media is known.[3]

The principal methods for measuring and visualizing phase shifts include ptychography and various types of holographic microscopy methods such as digital holographic microscopy, holographic interference microscopy and digital in-line holographic microscopy. Common to these methods is that an interference pattern (hologram) is recorded by a digital image sensor. From the recorded interference pattern, the intensity and the phase shift image is numerically created by a computer algorithm.[4]

Quantitative phase contrast microscopy is primarily used to observed unstained living cells. Measuring the phase delay images of biological cells provides quantitative information about the morphology and the drymass of individual cells.[5] Contrary to conventional phase contrast images[citation needed], phase shift images of living cells are suitable to be processed by image analysis software. This has led to the development of non-invasive live cell imaging and automated cell culture analysis systems based on quantitative phase contrast microscopy.[6]

See also

[edit]

References

[edit]
  1. ^ Etienne Cuche; Frédéric Bevilacqua; Christian Depeursinge (1999). "Digital holography for quantitative phase-contrast imaging". Optics Letters. 24 (5): 291–293. Bibcode:1999OptL...24..291C. doi:10.1364/OL.24.000291. PMID 18071483.
  2. ^ Park Y, Depeursinge C, Popescu G (2018). "Quantitative phase imaging in biomedicine". Nature Photonics. 12 (10): 578–589. Bibcode:2018NaPho..12..578P. doi:10.1038/s41566-018-0253-x. S2CID 256704142.
  3. ^ Manuel Kemmler; Markus Fratz; Dominik Giel; Norbert Saum; Albrecht Brandenburg; Christian Hoffmann (2007). "Noninvasive time-dependent cytometry monitoring by digital holography". Journal of Biomedical Optics. 12 (6): 064002. Bibcode:2007JBO....12f4002K. doi:10.1117/1.2804926. PMID 18163818. S2CID 40335328.
  4. ^ Myung K. Kim (2010). "Principles and techniques of digital holographic microscopy". SPIE Reviews. 1: 018005. Bibcode:2010SPIER...1a8005K. doi:10.1117/6.0000006.
  5. ^ Zangle T, Teitell M (2014). "Live-cell mass profiling: an emerging approach in quantitative biophysics". Nature Methods. 11 (12): 1221–1228. doi:10.1038/nmeth.3175. PMC 4319180. PMID 25423019.
  6. ^ Chen, Claire Lifan; Mahjoubfar, Ata; Tai, Li-Chia; Blaby, Ian K.; Huang, Allen; Niazi, Kayvan Reza; Jalali, Bahram (2016). "Deep Learning in Label-free Cell Classification". Scientific Reports. 6: 21471. Bibcode:2016NatSR...621471C. doi:10.1038/srep21471. PMC 4791545. PMID 26975219.published under CC BY 4.0 licensing
[edit]