A '''blocked rotor test''' is conducted on an [[induction motor]]. It is also known as short circuit test (because it is [[mechanical-electrical analogies#Mobility analogies|the mechanical analogy]] of a transformer [[short circuit test]]),<ref>U.A.Bakshi, M.V.Bakshi, ''Electrical Machines - II'', p. 6-7, Technical Publications, 2009 {{ISBN|8184315236}}.</ref> locked rotor test or stalled torque test.<ref>M.V. Deshpande, ''Electrical Machines'', p. 254, PHI Learning, 2011 {{ISBN|8120340264}}.</ref> From this test, [[short circuit current]] at [[Voltage|normal voltage]], [[power factor]] on short circuit, total [[Electrical reactance|leakage reactance]], and [[Torque|starting torque]] of the motor can be found.<ref>{{cite journal|last=de Swardt|first=Henk|url=http://www.mandc.co.za/pdfs/Locked_rotor_test_explained.pdf|title=The Locked rotor test explained|publisher=Marthinusen & Coutts (Pty.) Ltd|access-date=2012-06-27|archive-url=https://web.archive.org/web/20110516004026/http://www.mandc.co.za/pdfs/Locked_rotor_test_explained.pdf|archive-date=2011-05-16|url-status=dead}}</ref> It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an excessive current and rapidly overheat.<ref name=":0">{{cite book|url=https://books.google.com/books?id=V1pepm-1m-cC&q=Locked+rotor+test&pg=PA263|title=Industrial Power Engineering and Applications Handbook|date=8 October 2001|publisher=Newnes|isbn=9780080508634}}</ref> The test may be conducted at lower voltage because at the normal voltage the current through the windings would be high enough to rapidly overheat and damage them. The test may still be conducted at full voltage if it is brief enough to avoid overheating the windings or overloading the starting circuits, but requires much more care to be taken while performing the test.<ref name="Motor testing methods">{{cite web|url =http://www.eswtesters.com/motor_testing_methods.php|title =Motor testing methods|publisher =Electronic Systems of Wisconsin, Inc.|url-status =dead|archiveurl =https://web.archive.org/web/20121231225205/http://www.eswtesters.com/motor_testing_methods.php|archivedate =2012-12-31}}</ref> The ''blocked rotor torque test'' is less significant on [[Wound rotor motor|wound-rotor motors]] because the starting torque can be varied as desired although it may still be used to characterise the motor.<ref name=":0" />
A '''blocked rotor test''' is conducted on an [[induction motor]]. It is also known as [[short-circuit test]] (because it is [[mechanical–electrical analogies#Mobility analogies|the mechanical analogy]] of a transformer short-circuit test),<ref>U.A.Bakshi, M.V.Bakshi, ''Electrical Machines - II'', p. 6-7, Technical Publications, 2009 {{ISBN|8184315236}}.</ref> locked rotor test or stalled torque test.<ref>M.V. Deshpande, ''Electrical Machines'', p. 254, PHI Learning, 2011 {{ISBN|8120340264}}.</ref> From this test, [[short-circuit current]] at [[Voltage|normal voltage]], [[power factor]] on short circuit, total [[Electrical reactance|leakage reactance]], and [[Torque|starting torque]] of the motor can be found.
It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an excessive current and rapidly overheat.<ref name=":0">{{cite book|url=https://books.google.com/books?id=V1pepm-1m-cC&q=Locked+rotor+test&pg=PA263|title=Industrial Power Engineering and Applications Handbook|date=8 October 2001|publisher=Newnes|isbn=9780080508634}}</ref> The test may be conducted at lower voltage because at the normal voltage the current through the windings would be high enough to rapidly overheat and damage them. The test may still be conducted at full voltage if it is brief enough to avoid overheating the windings or overloading the starting circuits, but requires much more care to be taken while performing the test.<ref name="Motor testing methods">{{cite web|url =http://www.eswtesters.com/motor_testing_methods.php|title =Motor testing methods|publisher =Electronic Systems of Wisconsin, Inc.|url-status =dead|archiveurl =https://web.archive.org/web/20121231225205/http://www.eswtesters.com/motor_testing_methods.php|archivedate =2012-12-31}}</ref>
The ''blocked rotor torque test'' is less significant on [[Wound rotor motor|wound-rotor motors]] because the starting torque of these wound-rotor motors depend upon the external resistance added. However, it may still be used to characterise the motor.<ref name=":0" />


==Method==
==Method==
In the blocked rotor test, the [[Rotor (electric)|rotor]] is locked securely enough that it cannot break free.<ref>{{cite web|url =http://iitg.vlab.co.in/?sub=61&brch=168&sim=916&cnt=1712|title =Blocked rotor test|publisher =Sakshat virtual labs}}</ref> A low voltage is applied on the stator terminals so that there is [[full load current]] in the stator winding, and the current, voltage and power input are measured at that point. When the rotor is stationary, the [[slip (motors)|slip]], <math> s = 1 </math>.<ref>{{cite book|last =B.L. Theraja|first=A.K. Theraja| title = Electrical Technology volume 2|publisher= S. Chand|edition=Twenty third revised multicolour|year=2010|page=1317|isbn=978-81-219-2437-5}}</ref> The test is conducted at <math> 1/4 </math> the rated frequency as recommended by IEEE, because the rotor's effective resistance at low frequency may differ at high frequency.<ref>{{cite web|last =Knight|first =Dr Andy|url =http://www.ece.ualberta.ca/~knight/electrical_machines/induction/parameters/params.html|title =Electrical Machines|publisher =Department of Electrical and Computer engineering, University of Alberta|url-status =dead|archiveurl =https://archive.is/20121129213048/http://www.ece.ualberta.ca/~knight/electrical_machines/induction/parameters/params.html|archivedate =2012-11-29}}</ref><ref>{{cite journal|last=Pitis|first=CD |url=https://docs.google.com/viewer?a=v&q=cache:dqMYx9A7SR8J:www.eepublishers.co.za/images/upload/femco%2520squirrel.doc+&hl=en&gl=in&pid=bl&srcid=ADGEESg5Rz7fWQUOsorcMSEdx-w1qmBvd52ATrYU2Txc0O4MlIJOxcGYmiX1l6o_Yrwg3LwlChi83gSKgv8iEgHIr7f5mN5cxiXDvpJWo3HJx_ksx1uwqnECdBs_Dib77K8JPqhUu4T2&sig=AHIEtbQMHjRqDCfrS9x7QA8klVs3r2mHEA|title =femco squirrel.doc|publisher =Femco mining motors}}</ref> The test can be repeated for different values of voltage to ensure the values obtained are consistent. As the current through the stator may exceed the rated current, the test should be conducted quickly.<ref name="Motor testing methods"/> By using the parameters found by this test, the motor circle diagram can be constructed.<ref name="Deshpande">{{cite book|last =Deshpande|first =M.V.|url =https://books.google.com/books?id=7rwh4cw4C5gC&q=Locked+rotor+test&pg=PA254|title =Electrical Machines|date =30 May 2011|publisher =PHI Learning Pvt. Ltd|isbn =9788120340268}}</ref>
In the blocked rotor test, the [[Rotor (electric)|rotor]] is locked securely enough that it cannot break free.<ref>{{cite web|url =http://iitg.vlab.co.in/?sub=61&brch=168&sim=916&cnt=1712|title =Blocked rotor test|publisher =Sakshat virtual labs}}</ref> A low voltage is applied on the [[stator]] terminals so that there is [[full load current]] in the stator winding, and the current, voltage and power input are measured at that point. When the rotor is stationary, the [[slip (motors)|slip]], <math> s = 1 </math>.<ref>{{cite book|last =B.L. Theraja|first=A.K. Theraja| title = Electrical Technology volume 2|publisher= S. Chand|edition=Twenty third revised multicolour|year=2010|page=1317|isbn=978-81-219-2437-5}}</ref>
The test is conducted at <math> 1/4 </math> the rated frequency as recommended by IEEE, because the rotor's effective resistance at low frequency may differ at high frequency.<ref>{{cite web|last =Knight|first =Dr Andy|url =http://www.ece.ualberta.ca/~knight/electrical_machines/induction/parameters/params.html|title =Electrical Machines|publisher =Department of Electrical and Computer engineering, University of Alberta|url-status =dead|archiveurl =https://archive.today/20121129213048/http://www.ece.ualberta.ca/~knight/electrical_machines/induction/parameters/params.html|archivedate =2012-11-29}}</ref><ref>{{cite journal|last=Pitis|first=CD |url=https://docs.google.com/viewer?a=v&q=cache:dqMYx9A7SR8J:www.eepublishers.co.za/images/upload/femco%2520squirrel.doc+&hl=en&gl=in&pid=bl&srcid=ADGEESg5Rz7fWQUOsorcMSEdx-w1qmBvd52ATrYU2Txc0O4MlIJOxcGYmiX1l6o_Yrwg3LwlChi83gSKgv8iEgHIr7f5mN5cxiXDvpJWo3HJx_ksx1uwqnECdBs_Dib77K8JPqhUu4T2&sig=AHIEtbQMHjRqDCfrS9x7QA8klVs3r2mHEA|title =femco squirrel.doc|publisher =Femco mining motors}}</ref> The test can be repeated for different values of voltage to ensure the values obtained are consistent. As the current through the stator may exceed the rated current, the test should be conducted quickly.<ref name="Motor testing methods"/>
By using the parameters found by this test, the motor [[circle diagram]] can be constructed.<ref name="Deshpande">{{cite book|last =Deshpande|first =M.V.|url =https://books.google.com/books?id=7rwh4cw4C5gC&q=Locked+rotor+test&pg=PA254|title =Electrical Machines|date =30 May 2011|publisher =PHI Learning Pvt. Ltd|isbn =9788120340268}}</ref>


==Calculations involved==
==Calculations involved==


===Short circuit current at normal voltage===
===Short-circuit current at normal voltage===
<math> I_{S} </math> is the short circuit current at voltage <math> V_{S} </math><br>
<math> I_{S} </math> is the short-circuit current at voltage <math> V_{S} </math><br>
<math> I_{SN} </math> is the short circuit current at normal voltage <math> V </math><br>
<math> I_{SN} </math> is the short-circuit current at normal voltage <math> V </math><br>
<math> I_{SN} = I_{S} \times \frac {V} {V_{S}}</math>
<math> I_{SN} = I_{S} \times \frac {V} {V_{S}}</math>


===Short circuit power factor===
===Short-circuit power factor===
<math> W_{S} </math> is the total input power on short circuit<br>
<math> W_{S} </math> is the total input power on short circuit<br>
<math> V_{SL} </math> is the line voltage on short circuit<br>
<math> V_{SL} </math> is the line voltage on short circuit<br>
<math> I_{SL} </math> is the line current on short circuit<br>
<math> I_{SL} </math> is the line current on short circuit<br>
<math> cos \phi_{S} </math> is the short circuit power factor<br>
<math> cos \phi_{S} </math> is the short-circuit power factor<br>
<math> cos \phi_{S} = \frac {W_{S}} {{\sqrt{3}} {V_{SL}} {I_{SL}}} </math><ref name="Deshpande"/>
<math> cos \phi_{S} = \frac {W_{S}} {{\sqrt{3}} {V_{SL}} {I_{SL}}} </math><ref name="Deshpande"/>


===Leakage reactance===
===Leakage reactance===
<math> Z_{01} </math> is the short circuit impedance as referred to stator<br>
<math> Z_{01} </math> is the short-circuit impedance as referred to stator<br>
<math> X_{01} </math> is the leakage reactance per phase as referred to stator<br>
<math> X_{01} </math> is the leakage reactance per phase as referred to stator<br>
<math> Z_{01} = \frac \text {short circuit voltage per phase} \text {short circuit current} = \frac {V_{S}} {I_{S}} </math>
<math> Z_{01} = \frac \text {short-circuit voltage per phase} \text {short-circuit current} = \frac {V_{S}} {I_{S}} </math>


<math> W_{cu} </math> is the total copper loss<br>
<math> W_{cu} </math> is the total copper loss<br>
Line 34: Line 42:


==See also==
==See also==
*[[Open circuit test]]
* [[Open-circuit test]]
*[[Circle diagram]]
* [[Circle diagram]]


==References==
==References==

Latest revision as of 02:04, 19 November 2024

A blocked rotor test is conducted on an induction motor. It is also known as short-circuit test (because it is the mechanical analogy of a transformer short-circuit test),[1] locked rotor test or stalled torque test.[2] From this test, short-circuit current at normal voltage, power factor on short circuit, total leakage reactance, and starting torque of the motor can be found.

It is very important to know a motor's starting torque since if it is not enough to overcome the initial friction of its intended load then it will remain stationary while drawing an excessive current and rapidly overheat.[3] The test may be conducted at lower voltage because at the normal voltage the current through the windings would be high enough to rapidly overheat and damage them. The test may still be conducted at full voltage if it is brief enough to avoid overheating the windings or overloading the starting circuits, but requires much more care to be taken while performing the test.[4]

The blocked rotor torque test is less significant on wound-rotor motors because the starting torque of these wound-rotor motors depend upon the external resistance added. However, it may still be used to characterise the motor.[3]

Method

[edit]

In the blocked rotor test, the rotor is locked securely enough that it cannot break free.[5] A low voltage is applied on the stator terminals so that there is full load current in the stator winding, and the current, voltage and power input are measured at that point. When the rotor is stationary, the slip, .[6]

The test is conducted at the rated frequency as recommended by IEEE, because the rotor's effective resistance at low frequency may differ at high frequency.[7][8] The test can be repeated for different values of voltage to ensure the values obtained are consistent. As the current through the stator may exceed the rated current, the test should be conducted quickly.[4]

By using the parameters found by this test, the motor circle diagram can be constructed.[9]

Calculations involved

[edit]

Short-circuit current at normal voltage

[edit]

is the short-circuit current at voltage
is the short-circuit current at normal voltage

Short-circuit power factor

[edit]

is the total input power on short circuit
is the line voltage on short circuit
is the line current on short circuit
is the short-circuit power factor
[9]

Leakage reactance

[edit]

is the short-circuit impedance as referred to stator
is the leakage reactance per phase as referred to stator

is the total copper loss
is the core loss


See also

[edit]

References

[edit]
  1. ^ U.A.Bakshi, M.V.Bakshi, Electrical Machines - II, p. 6-7, Technical Publications, 2009 ISBN 8184315236.
  2. ^ M.V. Deshpande, Electrical Machines, p. 254, PHI Learning, 2011 ISBN 8120340264.
  3. ^ a b Industrial Power Engineering and Applications Handbook. Newnes. 8 October 2001. ISBN 9780080508634.
  4. ^ a b "Motor testing methods". Electronic Systems of Wisconsin, Inc. Archived from the original on 2012-12-31.
  5. ^ "Blocked rotor test". Sakshat virtual labs.
  6. ^ B.L. Theraja, A.K. Theraja (2010). Electrical Technology volume 2 (Twenty third revised multicolour ed.). S. Chand. p. 1317. ISBN 978-81-219-2437-5.