Knudsen number: Difference between revisions
m task, replaced: Int. J. Hydrogen Energy → International Journal of Hydrogen Energy |
Citation bot (talk | contribs) Added bibcode. | Use this bot. Report bugs. | Suggested by Abductive | Category:Dimensionless numbers of fluid mechanics | #UCB_Category 41/71 |
||
(47 intermediate revisions by 36 users not shown) | |||
Line 1: | Line 1: | ||
{{Short description|Dimensionless number relating to mean free path of a particle}} |
|||
{{more citations needed|date=March 2011}} |
{{more citations needed|date=March 2011}} |
||
The '''Knudsen number''' ('''Kn''') is a [[dimensionless number]] defined as the [[ratio]] of the molecular [[mean free path]] length to a [[Characteristic dimension|representative physical length scale]]. This length scale could be, for example, the [[radius]] of a body in a fluid. The number is named after [[Denmark|Danish]] physicist [[Martin Knudsen]] (1871–1949). |
The '''Knudsen number''' ('''Kn''') is a [[dimensionless number]] defined as the [[ratio]] of the molecular [[mean free path]] length to a [[Characteristic dimension|representative physical length scale]]. This length scale could be, for example, the [[radius]] of a body in a fluid. The number is named after [[Denmark|Danish]] physicist [[Martin Knudsen]] (1871–1949). |
||
Line 7: | Line 8: | ||
The Knudsen number is a dimensionless number defined as |
The Knudsen number is a dimensionless number defined as |
||
:<math>\mathrm{Kn} = \frac {\lambda}{L},</math> |
:<math>\mathrm{Kn}\ = \frac {\lambda}{L},</math> |
||
where |
where |
||
Line 13: | Line 14: | ||
: <math>L</math> = representative physical length scale [L<sup>1</sup>]. |
: <math>L</math> = representative physical length scale [L<sup>1</sup>]. |
||
The representative length scale considered, <math>L</math>, may correspond to various physical traits of a system, but most commonly relates to a ''gap length'' over which thermal transport or mass transport occurs through a gas phase. This is the case in porous and granular materials, where the thermal transport through a gas phase depends highly on its pressure and the consequent mean free path of molecules in this phase.<ref>{{cite journal| last1=Dai | |
The representative length scale considered, <math>L</math>, may correspond to various physical traits of a system, but most commonly relates to a ''gap length'' over which thermal transport or mass transport occurs through a gas phase. This is the case in porous and granular materials, where the thermal transport through a gas phase depends highly on its pressure and the consequent mean free path of molecules in this phase.<ref>{{cite journal| last1=Dai |display-authors=etal | title= Effective Thermal Conductivity of Submicron Powders: A Numerical Study| journal= Applied Mechanics and Materials| year=2016 | volume=846| pages=500–505| url=https://www.researchgate.net/publication/305644421 |doi=10.4028/www.scientific.net/AMM.846.500 |s2cid=114611104 }}</ref> For a [[Boltzmann gas]], the [[mean free path]] may be readily calculated, so that |
||
:<math>\mathrm{Kn} = \frac {k_\text{B} T}{\sqrt{2}\pi d^2 p L},</math> |
:<math>\mathrm{Kn}\ = \frac {k_\text{B} T}{\sqrt{2}\pi d^2 p L}=\frac {k_\text{B}}{\sqrt{2}\pi d^2 \rho R_{s} L},</math> |
||
where |
where |
||
: <math>k_\text{B}</math> is the [[Boltzmann constant]] (1. |
: <math>k_\text{B}</math> is the [[Boltzmann constant]] (1.380649 × 10<sup>−23</sup> J/K in [[SI]] units) [M<sup>1</sup> L<sup>2</sup> T<sup>−2</sup> Θ<sup>−1</sup>], |
||
: <math>T</math> is the [[thermodynamic temperature]] [θ<sup>1</sup>], |
: <math>T</math> is the [[thermodynamic temperature]] [θ<sup>1</sup>], |
||
: <math>d</math> is the particle hard-shell diameter [L<sup>1</sup>], |
: <math>d</math> is the particle hard-shell diameter [L<sup>1</sup>], |
||
: <math>p</math> is the |
: <math>p</math> is the static pressure [M<sup>1</sup> L<sup>−1</sup> T<sup>−2</sup>], |
||
: <math>R_{s}</math> is the [[Gas constant#Specific gas constant|specific gas constant]] [L<sup>2</sup> T<sup>−2</sup> θ<sup>−1</sup>] (287.05 J/(kg K) for air), |
|||
: <math>\rho</math> is the density [M<sup>1</sup> L<sup>−3</sup>]. |
|||
If the temperature is increased, but the ''volume'' kept constant, then the Knudsen number (and the mean free path) doesn't change (for an [[ideal gas]]). In this case, the density stays the same. If the temperature is increased, and the ''pressure'' kept constant, then the gas expands and therefore its density decreases. In this case, the mean free path increases and so does the Knudsen number. Hence, it may be helpful to keep in mind that the mean free path (and therefore the Knudsen number) is really dependent on the thermodynamic variable density (proportional to the reciprocal of density), and only indirectly on temperature and pressure. |
|||
⚫ | |||
⚫ | |||
==Relationship to Mach and Reynolds numbers in gases== |
==Relationship to Mach and Reynolds numbers in gases== |
||
Line 34: | Line 39: | ||
:<math>\bar{c} = \sqrt{\frac{8 k_\text{B} T}{\pi m}},</math> |
:<math>\bar{c} = \sqrt{\frac{8 k_\text{B} T}{\pi m}},</math> |
||
the mean free path is determined as follows:<ref name = "thermal">{{cite journal | last1= Dai | first1= W.| |
the [[mean free path]] is determined as follows:<ref name = "thermal">{{cite journal | last1= Dai | first1= W. |display-authors=etal | title= Influence of gas pressure on the effective thermal conductivity of ceramic breeder pebble beds | journal = [[Fusion Engineering and Design]] | year=2017 | volume=118| pages= 45–51|doi= 10.1016/j.fusengdes.2017.03.073 | bibcode= 2017FusED.118...45D }}</ref> |
||
:<math>\lambda = \frac{\mu}{\rho} \sqrt{\frac{\pi m}{2 k_\text{B} T}}.</math> |
:<math>\lambda = \frac{\mu}{\rho} \sqrt{\frac{\pi m}{2 k_\text{B} T}}.</math> |
||
Dividing through by ''L'' (some characteristic length), the Knudsen number is obtained: |
Dividing through by ''L'' (some characteristic length), the Knudsen number is obtained: |
||
:<math> \mathrm{Kn} = \frac{\lambda}{L} = \frac{\mu}{\rho L} \sqrt{\frac{\pi m}{2 k_\text{B} T}},</math> |
:<math> \mathrm{Kn}\ = \frac{\lambda}{L} = \frac{\mu}{\rho L} \sqrt{\frac{\pi m}{2 k_\text{B} T}},</math> |
||
where |
where |
||
Line 46: | Line 51: | ||
: ''m'' is the [[molecular mass]] [M<sup>1</sup>], |
: ''m'' is the [[molecular mass]] [M<sup>1</sup>], |
||
: ''k<sub>B</sub>'' is the [[Boltzmann constant]] [M<sup>1</sup> L<sup>2</sup> T<sup>−2</sup> θ<sup>−1</sup>], |
: ''k<sub>B</sub>'' is the [[Boltzmann constant]] [M<sup>1</sup> L<sup>2</sup> T<sup>−2</sup> θ<sup>−1</sup>], |
||
: |
: <math>\rho</math> is the density [M<sup>1</sup> L<sup>−3</sup>]. |
||
The dimensionless Mach number can be written as |
The dimensionless Mach number can be written as |
||
Line 73: | Line 78: | ||
The Mach, Reynolds and Knudsen numbers are therefore related by |
The Mach, Reynolds and Knudsen numbers are therefore related by |
||
:<math>\mathrm{Kn} = \frac{\mathrm{Ma}}{\mathrm{Re}} \sqrt{\frac{\gamma \pi}{2}}.</math> |
:<math>\mathrm{Kn}\ = \frac{\mathrm{Ma}}{\mathrm{Re}} \sqrt{\frac{\gamma \pi}{2}}.</math> |
||
==Application== |
==Application== |
||
The Knudsen number can be used to determine the rarefaction of a flow:<ref name="karniadakis-00">{{cite book|title=Microflows and nanoflows: fundamentals and simulation|year=2000|publisher=Springer|author=Karniadakis, G. and Beskok, A. and Aluru, N.}}</ref> |
|||
⚫ | Problems with high Knudsen numbers include the calculation of the motion of a [[dust]] particle through the lower [[Earth's atmosphere|atmosphere]] and the motion of a [[satellite]] through the [[exosphere]]. One of the most widely used applications for the Knudsen number is in [[microfluidics]] and [[MEMS]] device design. Movements of fluids in situations with a high Knudsen number are said to exhibit [[Knudsen flow]]. |
||
<ref name="Ziarani-00">{{cite conference|last=Ziarani A. S.|first=Aguilera R., Cui X. C.|title= Permeability of Tight Sand and Shale Formations: A Dual Mechanism Approach for Micro and Nanodarcy Reservoirs|publisher=SPE |year=2020|isbn=978-1-61399-685-0|conference=SPE Canada Unconventional Resources Conference. SPE-200010-MS}}</ref> |
|||
* <math>\mathrm{Kn} < 0.01 </math>: [[Continuum mechanics|Continuum flow]] |
|||
⚫ | Airflow around an [[aircraft]] has a low Knudsen number, making it firmly in the realm of continuum mechanics. Using the Knudsen number an adjustment for [[Stokes' law]] can be used in the [[Cunningham correction factor]], this is a drag force correction due to slip in small particles (i.e. ''d''<sub>''p''</sub> < 5 |
||
* <math>0.01 < \mathrm{Kn} < 0.1 </math>: Slip flow |
|||
* <math> 0.1 < \mathrm{Kn} < 10 </math>: Transitional flow |
|||
⚫ | Mixtures of gases with different molecular masses can be partly separated by sending the mixture through small holes of a thin wall because the numbers of molecules that pass through a hole is proportional to the pressure of the gas and inversely proportional to its molecular mass. The technique has been used to separate [[isotope|isotopic]] mixtures, such as [[uranium]], using porous membranes,<ref>{{cite book | last = Villani | first = S. | title = Isotope Separation | publisher = American Nuclear Society | date = 1976 | location = Hinsdale, Ill.}}</ref> It has also been successfully demonstrated for use in [[hydrogen production]] from water.<ref>{{cite journal | doi = 10.1016/S0360-3199(97)00038-4 | last = Kogan | first = A. | title = Direct solar thermal splitting of water and on-site separation of the products - II. Experimental feasibility study | journal = International Journal of Hydrogen Energy | volume = 23 | issue = 2 | pages = 89–98 | publisher = Elsevier Science Ltd | location = Great Britain | date = 1998}}</ref> |
||
* <math>\mathrm{Kn} > 10 </math>: [[Free molecular flow]]<ref name=Laurendeau>{{cite book |
|||
One source says that Kn > 10 is a suitable criterion for distinguishing molecular flow from continuum flow.<ref name=Laurendeau>{{cite book |
|||
|title=Statistical thermodynamics: fundamentals and applications |
|title=Statistical thermodynamics: fundamentals and applications |
||
|first1=Normand M. |
|first1=Normand M. |
||
Line 93: | Line 97: | ||
|url=https://books.google.com/books?id=QF6iMewh4KMC}}, [https://books.google.com/books?id=QF6iMewh4KMC&pg=PA434 Appendix N, page 434] |
|url=https://books.google.com/books?id=QF6iMewh4KMC}}, [https://books.google.com/books?id=QF6iMewh4KMC&pg=PA434 Appendix N, page 434] |
||
</ref> |
</ref> |
||
This regime classification is empirical and problem dependent but has proven useful to adequately model flows.<ref name="karniadakis-00" /> |
|||
⚫ | |||
⚫ | Problems with high Knudsen numbers include the calculation of the motion of a [[dust]] particle through the lower [[Earth's atmosphere|atmosphere]] and the motion of a [[satellite]] through the [[exosphere]]. One of the most widely used applications for the Knudsen number is in [[microfluidics]] and [[MEMS]] device design where flows range from continuum to free-molecular.<ref name="karniadakis-00" /> In recent years, it has been applied in other disciplines such as transport in porous media, e.g., petroleum reservoirs.<ref name="Ziarani-00"/> Movements of fluids in situations with a high Knudsen number are said to exhibit [[Knudsen flow]], also called [[free molecular flow]].{{cn|date=August 2024}}<!--I found definition claiming Knudsen flow is transitional.--> |
||
⚫ | Airflow around an [[aircraft]] such as an [[airliner]] has a low Knudsen number, making it firmly in the realm of continuum mechanics. Using the Knudsen number an adjustment for [[Stokes' law]] can be used in the [[Cunningham correction factor]], this is a drag force correction due to slip in small particles (i.e. ''d''<sub>''p''</sub> < 5 μm). The flow of water through a nozzle will usually be a situation with a low Knudsen number.<ref name=Laurendeau/> |
||
⚫ | Mixtures of gases with different molecular masses can be partly separated by sending the mixture through small holes of a thin wall because the numbers of molecules that pass through a hole is proportional to the pressure of the gas and inversely proportional to its molecular mass. The technique has been used to separate [[isotope|isotopic]] mixtures, such as [[uranium]], using porous membranes,<ref>{{cite book | last = Villani | first = S. | title = Isotope Separation | publisher = American Nuclear Society | date = 1976 | location = Hinsdale, Ill.}}</ref> It has also been successfully demonstrated for use in [[hydrogen production]] from water.<ref>{{cite journal | doi = 10.1016/S0360-3199(97)00038-4 | last = Kogan | first = A. | title = Direct solar thermal splitting of water and on-site separation of the products - II. Experimental feasibility study | journal = International Journal of Hydrogen Energy | volume = 23 | issue = 2 | pages = 89–98 | publisher = Elsevier Science Ltd | location = Great Britain | date = 1998| bibcode = 1998IJHE...23...89K }}</ref> |
||
The Knudsen number also plays an important role in thermal conduction in gases. For insulation materials, for example, where gases are contained under low pressure, the Knudsen number should be as high as possible to ensure low [[thermal conductivity]].<ref>{{Cite web|url=https://www.tec-science.com/thermodynamics/heat/thermal-conductivity-of-gases/|title=Thermal conductivity of gases|last=tec-science|date=2020-01-27|website=tec-science|language=en-US|access-date=2020-03-22}}</ref> |
|||
==See also== |
==See also== |
||
* |
* {{annotated link|Cunningham correction factor}} |
||
* |
* {{annotated link|Fluid dynamics}} |
||
* |
* {{annotated link|Mach number}} |
||
* {{annotated link|Free molecular flow}} |
|||
* [[Knudsen flow]] |
|||
* |
* {{annotated link|Knudsen diffusion}} |
||
* |
* {{annotated link|Knudsen paradox}} |
||
== References == |
== References == |
||
<references /> |
|||
{{Reflist}} |
|||
⚫ | |||
==External links== |
==External links== |
||
Line 110: | Line 124: | ||
{{NonDimFluMech}} |
{{NonDimFluMech}} |
||
{{Authority control}} |
|||
[[Category:Dimensionless numbers]] |
[[Category:Dimensionless numbers]] |
Latest revision as of 04:10, 21 November 2024
This article needs additional citations for verification. (March 2011) |
The Knudsen number (Kn) is a dimensionless number defined as the ratio of the molecular mean free path length to a representative physical length scale. This length scale could be, for example, the radius of a body in a fluid. The number is named after Danish physicist Martin Knudsen (1871–1949).
The Knudsen number helps determine whether statistical mechanics or the continuum mechanics formulation of fluid dynamics should be used to model a situation. If the Knudsen number is near or greater than one, the mean free path of a molecule is comparable to a length scale of the problem, and the continuum assumption of fluid mechanics is no longer a good approximation. In such cases, statistical methods should be used.
Definition
[edit]The Knudsen number is a dimensionless number defined as
where
- = mean free path [L1],
- = representative physical length scale [L1].
The representative length scale considered, , may correspond to various physical traits of a system, but most commonly relates to a gap length over which thermal transport or mass transport occurs through a gas phase. This is the case in porous and granular materials, where the thermal transport through a gas phase depends highly on its pressure and the consequent mean free path of molecules in this phase.[1] For a Boltzmann gas, the mean free path may be readily calculated, so that
where
- is the Boltzmann constant (1.380649 × 10−23 J/K in SI units) [M1 L2 T−2 Θ−1],
- is the thermodynamic temperature [θ1],
- is the particle hard-shell diameter [L1],
- is the static pressure [M1 L−1 T−2],
- is the specific gas constant [L2 T−2 θ−1] (287.05 J/(kg K) for air),
- is the density [M1 L−3].
If the temperature is increased, but the volume kept constant, then the Knudsen number (and the mean free path) doesn't change (for an ideal gas). In this case, the density stays the same. If the temperature is increased, and the pressure kept constant, then the gas expands and therefore its density decreases. In this case, the mean free path increases and so does the Knudsen number. Hence, it may be helpful to keep in mind that the mean free path (and therefore the Knudsen number) is really dependent on the thermodynamic variable density (proportional to the reciprocal of density), and only indirectly on temperature and pressure.
For particle dynamics in the atmosphere, and assuming standard temperature and pressure, i.e. 0 °C and 1 atm, we have ≈ 8×10−8 m (80 nm).
Relationship to Mach and Reynolds numbers in gases
[edit]The Knudsen number can be related to the Mach number and the Reynolds number.
Using the dynamic viscosity
with the average molecule speed (from Maxwell–Boltzmann distribution)
the mean free path is determined as follows:[2]
Dividing through by L (some characteristic length), the Knudsen number is obtained:
where
- is the average molecular speed from the Maxwell–Boltzmann distribution [L1 T−1],
- T is the thermodynamic temperature [θ1],
- μ is the dynamic viscosity [M1 L−1 T−1],
- m is the molecular mass [M1],
- kB is the Boltzmann constant [M1 L2 T−2 θ−1],
- is the density [M1 L−3].
The dimensionless Mach number can be written as
where the speed of sound is given by
where
- U∞ is the freestream speed [L1 T−1],
- R is the Universal gas constant (in SI, 8.314 47215 J K−1 mol−1) [M1 L2 T−2 θ−1 mol−1],
- M is the molar mass [M1 mol−1],
- is the ratio of specific heats [1].
The dimensionless Reynolds number can be written as
Dividing the Mach number by the Reynolds number:
and by multiplying by yields the Knudsen number:
The Mach, Reynolds and Knudsen numbers are therefore related by
Application
[edit]The Knudsen number can be used to determine the rarefaction of a flow:[3] [4]
- : Continuum flow
- : Slip flow
- : Transitional flow
- : Free molecular flow[5]
This regime classification is empirical and problem dependent but has proven useful to adequately model flows.[3] [6]
Problems with high Knudsen numbers include the calculation of the motion of a dust particle through the lower atmosphere and the motion of a satellite through the exosphere. One of the most widely used applications for the Knudsen number is in microfluidics and MEMS device design where flows range from continuum to free-molecular.[3] In recent years, it has been applied in other disciplines such as transport in porous media, e.g., petroleum reservoirs.[4] Movements of fluids in situations with a high Knudsen number are said to exhibit Knudsen flow, also called free molecular flow.[citation needed]
Airflow around an aircraft such as an airliner has a low Knudsen number, making it firmly in the realm of continuum mechanics. Using the Knudsen number an adjustment for Stokes' law can be used in the Cunningham correction factor, this is a drag force correction due to slip in small particles (i.e. dp < 5 μm). The flow of water through a nozzle will usually be a situation with a low Knudsen number.[5]
Mixtures of gases with different molecular masses can be partly separated by sending the mixture through small holes of a thin wall because the numbers of molecules that pass through a hole is proportional to the pressure of the gas and inversely proportional to its molecular mass. The technique has been used to separate isotopic mixtures, such as uranium, using porous membranes,[7] It has also been successfully demonstrated for use in hydrogen production from water.[8]
The Knudsen number also plays an important role in thermal conduction in gases. For insulation materials, for example, where gases are contained under low pressure, the Knudsen number should be as high as possible to ensure low thermal conductivity.[9]
See also
[edit]- Cunningham correction factor – Number used to correct drag calculations for small particles in a fluid
- Fluid dynamics – Aspects of fluid mechanics involving flow
- Mach number – Ratio of speed of an object moving through fluid and local speed of sound
- Free molecular flow – Gas flow with a relatively large mean free molecular path
- Knudsen diffusion – Particle behavior in systems of length less than the mean free path
- Knudsen paradox – Apparently anomalous flow in channels
References
[edit]- ^ Dai; et al. (2016). "Effective Thermal Conductivity of Submicron Powders: A Numerical Study". Applied Mechanics and Materials. 846: 500–505. doi:10.4028/www.scientific.net/AMM.846.500. S2CID 114611104.
- ^ Dai, W.; et al. (2017). "Influence of gas pressure on the effective thermal conductivity of ceramic breeder pebble beds". Fusion Engineering and Design. 118: 45–51. Bibcode:2017FusED.118...45D. doi:10.1016/j.fusengdes.2017.03.073.
- ^ a b c Karniadakis, G. and Beskok, A. and Aluru, N. (2000). Microflows and nanoflows: fundamentals and simulation. Springer.
{{cite book}}
: CS1 maint: multiple names: authors list (link) - ^ a b Ziarani A. S., Aguilera R., Cui X. C. (2020). Permeability of Tight Sand and Shale Formations: A Dual Mechanism Approach for Micro and Nanodarcy Reservoirs. SPE Canada Unconventional Resources Conference. SPE-200010-MS. SPE. ISBN 978-1-61399-685-0.
{{cite conference}}
: CS1 maint: multiple names: authors list (link) - ^ a b Laurendeau, Normand M. (2005). Statistical thermodynamics: fundamentals and applications. Cambridge University Press. p. 306. ISBN 0-521-84635-8., Appendix N, page 434
- ^ Cussler, E. L. (1997). Diffusion: Mass Transfer in Fluid Systems. Cambridge University Press. ISBN 0-521-45078-0.
- ^ Villani, S. (1976). Isotope Separation. Hinsdale, Ill.: American Nuclear Society.
- ^ Kogan, A. (1998). "Direct solar thermal splitting of water and on-site separation of the products - II. Experimental feasibility study". International Journal of Hydrogen Energy. 23 (2). Great Britain: Elsevier Science Ltd: 89–98. Bibcode:1998IJHE...23...89K. doi:10.1016/S0360-3199(97)00038-4.
- ^ tec-science (2020-01-27). "Thermal conductivity of gases". tec-science. Retrieved 2020-03-22.