An '''isolation valve''' is a [[valve]] in a [[fluid handling system]] that stops the flow of [[process media]] to a given location, usually for [[Maintenance, repair, and operations|maintenance]] or [[safety]] purposes.<ref>{{cite book|last=Nesbitt|first=Brian|title=Handbook of Valves and Actuators|pages=82|url=http://books.google.com/books?id=mzsF34JBXGoC&pg=PA82&dq=isolation+valve&hl=en&sa=X&ei=U4xFT9mdFsrw0gGYluHpAw&ved=0CDkQ6AEwAA#v=onepage&q=isolation%20valve&f=false}}</ref> They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system.<ref>{{cite book|last=Royals|first=William T.|title=Flammability and sensitivity of materials in oxygen-enriched atmospheres|year=1997|publisher=American Society for Testing and Materials|isbn=0-8031-2401-5|pages=433|url=http://books.google.com/books?id=JUAdRmfr96AC&pg=PA433&dq=%22isolation+valve%22&hl=en&sa=X&ei=d4FGT5ycAsfbgQeJj-WfDg&ved=0CGQQ6AEwBA#v=onepage&q=%22isolation%20valve%22&f=false}}</ref> A valve is classified as an isolation valve because of its intended function in a system, not because of the architecture of the valve itself. Therefore, many different types of valves can be classified as isolation valves.
An '''isolation valve''' is a [[valve]] in a [[fluid handling system]] that stops the flow of [[process media]] to a given location, usually for [[Maintenance, repair, and operations|maintenance]] or [[safety]] purposes.<ref>{{cite book|last=Nesbitt|first=Brian|title=Handbook of Valves and Actuators|date=19 April 2011|pages=82|publisher=Elsevier |isbn=9780080549286|url=https://books.google.com/books?id=mzsF34JBXGoC&q=isolation+valve&pg=PA82}}</ref> They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system.<ref>{{cite book|last=Royals|first=William T.|title=Flammability and sensitivity of materials in oxygen-enriched atmospheres|year=1997|publisher=American Society for Testing and Materials|isbn=0-8031-2401-5|pages=433|url=https://books.google.com/books?id=JUAdRmfr96AC&q=%22isolation+valve%22&pg=PA433}}</ref> A valve is classified as an isolation valve because of its intended function in a system, not because of the type of the valve itself. Therefore, many different types of valves can be classified as isolation valves.


To easily understand the concept of an isolation valve, one can think of the valves ''under'' a kitchen or bathroom sink in a typical household. These valves are normally left open so that the user can control the flow of water with the spigot above the sink, and does not need to reach under the counter to start or stop the water flow. However, if the spigot needs to be replaced (i.e. maintenance needs to take place on the system), the isolation valves are shut to stop the flow of water when the spigot is removed. In this system, the isolation valves and the spigot may even be the same type of valve. However, due to their function they are classified as the isolation valves and, in the case of the spigot, the [[control valves]].
To easily understand the concept of an isolation valve, one can think of the valves ''under'' a kitchen or bathroom sink in a typical household. These valves are normally left open so that the user can control the flow of water with the spigot above the sink, and does not need to reach under the counter to start or stop the water flow. However, if the spigot needs to be replaced (i.e. maintenance needs to take place on the system), the isolation valves are shut to stop the flow of water when the spigot is removed. In this system, the isolation valves and the spigot may even be the same type of valve. However, due to their function they are classified as the isolation valves and, in the case of the spigot, the [[control valves]]. As the isolation valve is intended to be operated infrequently and only in the fully on or fully off positions, they are often inferior quality [[globe valves]]. These less expensive styles lack a bonnet and stem seal in favor of threading the stem directly into the body. The stem is covered with a rubber washer and metal cap similar in appearance to a [[Valve#Components|gland nut]]. Because they lack a stem seal they will leak unless fully closed ''and'' installed in the correct direction or fully open, causing the disk to compress the top washer against the stem.


== Process plant practice ==
==Common Applications==
Isolation valves can be in the normally open position (NO) or normally closed (NC). Normally open valves are located between [[Pressure vessel|pressure vessels]], [[Pump|pumps]], [[Compressor|compressors]], tanks, [[Pressure sensor|pressure sensors]], liquid [[Level sensor|level measurement]] [[Instrumentation in petrochemical industries|instrumentation]] and other components and allow fluids to flow between components, or to be connected to sensors.<ref name=":0">{{Cite book|title=Perry's chemical engineers' handbook|last=Green|first=John W|publisher=McGraw Hill|year=1997|isbn=0-07-049841-5|pages=Section 10 - Transport and Storage of Fluids}}</ref> The controlled closure of open valves enables the isolation of plant components for testing or maintenance of equipment, or allows flow of fluid to specific flow paths.<ref name=":1">{{Cite book|title=Engineering Data Book|last=Gas Processors Suppliers Association|publisher=Gas Processors Suppliers Association|year=2004|location=Tulsa, Oklahoma|pages=Section 17 Fluid Flow and Piping}}</ref> Normally closed valves are used to connect fluids and process components to other systems only when required. Vent and drain valves are examples of normally closed valves which are only opened when required to depressurise (vent) or drain fluids from a system.


Isolation valves must effectively stop the passage of fluids.<ref name=":1" /> [[Gate valve|Gate valves]], [[Ball valve|ball valves]] and plug valves are generally considered to provide tight and effective shut-off. [[Globe valve|Globe valves]] and [[Butterfly valve|Butterfly valves]] may not be tight shut-off due to wear on the plug or the seat, or due to their design, and may not be appropriate to provide effective isolation.<ref name=":0" />
*Firewater control<ref>{{cite book|last=Nolan|first=Dennis|title=Handbook of Fire and Explosion Protection Engineering Principles: For Oil|year=2011|publisher=Elsevier, Inc|isbn=978-1-4377-7857-1|pages=220|url=http://books.google.com/books?id=WeslZYR1wH0C&pg=PA220&dq=isolation+valve&hl=en&sa=X&ei=U4xFT9mdFsrw0gGYluHpAw&ved=0CGIQ6AEwBg#v=onepage&q=isolation%20valve&f=false}}</ref>

*[[Pipeline transport|Pipeline]] safety systems<ref>{{cite book|last=Menon|first=E. Shashi|title=Pipeline Planning and Construction Field Manual|year=2011|publisher=Elsevier, Inc|pages=396|url=http://books.google.com/books?id=EK8RmsbyTVAC&pg=PA396&dq=isolation+valve&hl=en&sa=X&ei=U4xFT9mdFsrw0gGYluHpAw&ved=0CGgQ6AEwBw#v=onepage&q=isolation%20valve&f=false}}</ref>
Some valves are in a safety critical service and are secured, or otherwise locked, in an open or closed position.<ref name=":2">{{Cite web|url=http://www.hse.gov.uk/pUbns/priced/hsg253.pdf|title=The safe isolation of plant and equipment|last=HSE|date=2006|website=Health and Safety Executive|access-date=2 December 2019}}</ref> [[Plant process and emergency shutdown systems|Plant shutdown]] instrumentation must be effectively connected to the plant at all times, therefore the isolation valves associated with such equipment must be secured in the open position to prevent inadvertent movement or closure.<ref name=":2" /> Securing mechanisms include car-seals, chain and padlocks and proprietary securing devices. Isolation valves in a flare, relief or vent system must ensure that a flow path is always available to the [[Gas flare|flare]] or vent. These valves are secured in the open position (LO). Drain valves that connect a high pressure system to a low pressure drain system are locked in the closed position (LC) to prevent potential over-pressurisation of the drain system.<ref name=":0" /> Removal of locks from secured valves is only undertaken in specified and controlled conditions such as under a ‘[[Permit To Work|permit to work]]’ system. Some relief or [[Relief valve|pressure relief valves]] are ‘paired’ to provide a duty and a standby valve, the associated isolation valves are [[Interlock (engineering)|interlock]]<nowiki/>ed such that at least one relief valve is connected to the system being protected at all times.<ref name=":2" />
*Residential plumbing systems (both water and gas)<ref>{{cite book|last=Joyce|first=Michael A.|title=Residential Construction Academy - Plumbing, Second Edition|year=2012|publisher=Delmar, Cengage Learning|isbn=978-1-111-30777-6|pages=116|url=http://books.google.com/books?id=T5bk-0c6pa8C&pg=PA116&dq=%22isolation+valve%22&hl=en&sa=X&ei=d4FGT5ycAsfbgQeJj-WfDg&ved=0CFgQ6AEwAg#v=onepage&q=%22isolation%20valve%22&f=false}}</ref>

*[[Nuclear reactors]]<ref>{{cite web|title=Information Notice No. 85-71: CONTAINMENT INTEGRATED LEAK RATE TESTS|url=http://www.nrc.gov/reading-rm/doc-collections/gen-comm/info-notices/1985/in85071.html|publisher=United States Nuclear Regulatory Commission|accessdate=25 February 2012}}</ref>
A single valve may provide effective isolation between the live plant and the system being maintained. However, for hazardous systems a more effective means of isolation is required. This may comprise a ‘[[Block and bleed manifold|double block]]’ consisting of two valves in series. Still more effective is a ‘[[Block and bleed manifold|double block and bleed]]’ comprising two isolation valves in series plus a bleed valve between them. The bleed valve enables the integrity of the valve on the hazardous side to be monitored.<ref name=":2" />
*[[oil well|Oil and gas wells]]<ref>{{cite book|last=McAleese|first=Stuart|title=Operational aspects of oil and gas well testing|year=2000|publisher=Elsevier|isbn=0-444-50311-0|pages=69|url=http://books.google.com/books?id=6ebVyvL3JAIC&pg=PA69&dq=isolation+valve&hl=en&sa=X&ei=nzdIT9OgDsL2gAf6qKXwDQ&ved=0CE4Q6AEwAjgK#v=onepage&q=isolation%20valve&f=false}}</ref>

==Common applications==

*Firewater control<ref>{{cite book|last=Nolan|first=Dennis|title=Handbook of Fire and Explosion Protection Engineering Principles: For Oil|year=2011|publisher=Elsevier, Inc|isbn=978-1-4377-7857-1|pages=220|url=https://books.google.com/books?id=WeslZYR1wH0C&q=isolation+valve&pg=PA220}}</ref>
*[[Pipeline transport|Pipeline]] safety systems<ref>{{cite book|last=Menon|first=E. Shashi|title=Pipeline Planning and Construction Field Manual|year=2011|publisher=Elsevier, Inc|pages=396|isbn=9780123838544|url=https://books.google.com/books?id=EK8RmsbyTVAC&q=isolation+valve&pg=PA396}}</ref>
*Residential plumbing systems (both water and gas)<ref>{{cite book|last=Joyce|first=Michael A.|title=Residential Construction Academy - Plumbing, Second Edition|year=2012|publisher=Delmar, Cengage Learning|isbn=978-1-111-30777-6|pages=116|url=https://books.google.com/books?id=T5bk-0c6pa8C&q=%22isolation+valve%22&pg=PA116}}</ref>
*[[Nuclear reactors]]<ref>{{cite web|title=Information Notice No. 85-71: CONTAINMENT INTEGRATED LEAK RATE TESTS|url=https://www.nrc.gov/reading-rm/doc-collections/gen-comm/info-notices/1985/in85071.html|publisher=United States Nuclear Regulatory Commission|access-date=25 February 2012}}</ref>
*[[oil well|Oil and gas wells]]<ref>{{cite book|last=McAleese|first=Stuart|title=Operational aspects of oil and gas well testing|year=2000|publisher=Elsevier|isbn=0-444-50311-0|pages=69|url=https://books.google.com/books?id=6ebVyvL3JAIC&q=isolation+valve&pg=PA69}}</ref>
*[[Chemical plant]]
*[[Oil production plant]]
*[[Power plant]]

== See also ==

* [[Valve|Valves]]
* [[Shutdown valve]]
* [[Globe valve]]
* [[Ball valve]]
* [[Gate valve]]
* [[Plug valve]]
* [[Butterfly valve|Butterfly valves]]
* [[Piping and instrumentation diagram|Piping & Instrumentation Diagrams]]


== References ==
== References ==
{{Reflist}}
{{Reflist}}

{{mech-engineering-stub}}


<!--- Categories --->
<!--- Categories --->

[[Category:Piping]]
[[Category:Piping]]
[[Category:Valves]]
[[Category:Valves]]

Latest revision as of 07:49, 20 December 2024

An isolation valve is a valve in a fluid handling system that stops the flow of process media to a given location, usually for maintenance or safety purposes.[1] They can also be used to provide flow logic (selecting one flow path versus another), and to connect external equipment to a system.[2] A valve is classified as an isolation valve because of its intended function in a system, not because of the type of the valve itself. Therefore, many different types of valves can be classified as isolation valves.

To easily understand the concept of an isolation valve, one can think of the valves under a kitchen or bathroom sink in a typical household. These valves are normally left open so that the user can control the flow of water with the spigot above the sink, and does not need to reach under the counter to start or stop the water flow. However, if the spigot needs to be replaced (i.e. maintenance needs to take place on the system), the isolation valves are shut to stop the flow of water when the spigot is removed. In this system, the isolation valves and the spigot may even be the same type of valve. However, due to their function they are classified as the isolation valves and, in the case of the spigot, the control valves. As the isolation valve is intended to be operated infrequently and only in the fully on or fully off positions, they are often inferior quality globe valves. These less expensive styles lack a bonnet and stem seal in favor of threading the stem directly into the body. The stem is covered with a rubber washer and metal cap similar in appearance to a gland nut. Because they lack a stem seal they will leak unless fully closed and installed in the correct direction or fully open, causing the disk to compress the top washer against the stem.

Process plant practice

[edit]

Isolation valves can be in the normally open position (NO) or normally closed (NC). Normally open valves are located between pressure vessels, pumps, compressors, tanks, pressure sensors, liquid level measurement instrumentation and other components and allow fluids to flow between components, or to be connected to sensors.[3] The controlled closure of open valves enables the isolation of plant components for testing or maintenance of equipment, or allows flow of fluid to specific flow paths.[4] Normally closed valves are used to connect fluids and process components to other systems only when required. Vent and drain valves are examples of normally closed valves which are only opened when required to depressurise (vent) or drain fluids from a system.

Isolation valves must effectively stop the passage of fluids.[4] Gate valves, ball valves and plug valves are generally considered to provide tight and effective shut-off. Globe valves and Butterfly valves may not be tight shut-off due to wear on the plug or the seat, or due to their design, and may not be appropriate to provide effective isolation.[3]

Some valves are in a safety critical service and are secured, or otherwise locked, in an open or closed position.[5] Plant shutdown instrumentation must be effectively connected to the plant at all times, therefore the isolation valves associated with such equipment must be secured in the open position to prevent inadvertent movement or closure.[5] Securing mechanisms include car-seals, chain and padlocks and proprietary securing devices. Isolation valves in a flare, relief or vent system must ensure that a flow path is always available to the flare or vent. These valves are secured in the open position (LO). Drain valves that connect a high pressure system to a low pressure drain system are locked in the closed position (LC) to prevent potential over-pressurisation of the drain system.[3] Removal of locks from secured valves is only undertaken in specified and controlled conditions such as under a ‘permit to work’ system. Some relief or pressure relief valves are ‘paired’ to provide a duty and a standby valve, the associated isolation valves are interlocked such that at least one relief valve is connected to the system being protected at all times.[5]

A single valve may provide effective isolation between the live plant and the system being maintained. However, for hazardous systems a more effective means of isolation is required. This may comprise a ‘double block’ consisting of two valves in series. Still more effective is a ‘double block and bleed’ comprising two isolation valves in series plus a bleed valve between them. The bleed valve enables the integrity of the valve on the hazardous side to be monitored.[5]

Common applications

[edit]

See also

[edit]

References

[edit]
  1. ^ Nesbitt, Brian (19 April 2011). Handbook of Valves and Actuators. Elsevier. p. 82. ISBN 9780080549286.
  2. ^ Royals, William T. (1997). Flammability and sensitivity of materials in oxygen-enriched atmospheres. American Society for Testing and Materials. p. 433. ISBN 0-8031-2401-5.
  3. ^ a b c Green, John W (1997). Perry's chemical engineers' handbook. McGraw Hill. pp. Section 10 - Transport and Storage of Fluids. ISBN 0-07-049841-5.
  4. ^ a b Gas Processors Suppliers Association (2004). Engineering Data Book. Tulsa, Oklahoma: Gas Processors Suppliers Association. pp. Section 17 Fluid Flow and Piping.
  5. ^ a b c d HSE (2006). "The safe isolation of plant and equipment" (PDF). Health and Safety Executive. Retrieved 2 December 2019.
  6. ^ Nolan, Dennis (2011). Handbook of Fire and Explosion Protection Engineering Principles: For Oil. Elsevier, Inc. p. 220. ISBN 978-1-4377-7857-1.
  7. ^ Menon, E. Shashi (2011). Pipeline Planning and Construction Field Manual. Elsevier, Inc. p. 396. ISBN 9780123838544.
  8. ^ Joyce, Michael A. (2012). Residential Construction Academy - Plumbing, Second Edition. Delmar, Cengage Learning. p. 116. ISBN 978-1-111-30777-6.
  9. ^ "Information Notice No. 85-71: CONTAINMENT INTEGRATED LEAK RATE TESTS". United States Nuclear Regulatory Commission. Retrieved 25 February 2012.
  10. ^ McAleese, Stuart (2000). Operational aspects of oil and gas well testing. Elsevier. p. 69. ISBN 0-444-50311-0.