The [[International Space Station]] (ISS) '''External Active Thermal Control System''' (EATCS)<ref>http://www.nasa.gov/pdf/473486main_iss_atcs_overview.pdf</ref> maintains an equilibrium when the ISS environment or heat loads exceed the capabilities of the Passive Thermal Control System (PTCS). Note Elements of the PTCS are external surface materials, insulation such as MLI, or Heat Pipes. The EATCS provides [[heat rejection]] capabilities for all the US pressurised modules, including the JEM and COF as well as the main power distribution electronics of the S0, S1 and P1 Trusses. The EATCS consists of two independent Loops (Loop A & Loop B), they both use mechanically pumped Ammonia in fluid state, in closed-loop circuits. The EATCS is capable of rejecting up to 70&nbsp;kW, and provides a substantial upgrade in heat rejection capacity from the 14&nbsp;kW capability of the Early External Active Twermal Control System (EEATCS) via the Early Ammonia Servicer (EAS), which was launched on [[STS-105]] and installed onto the P6 Truss.<ref>http://www.nasa.gov/pdf/473486main_iss_atcs_overview.pdf</ref>
The [[International Space Station]] (ISS) '''External Active Thermal Control System''' (EATCS)<ref name="iss_atcs_overview">{{cite web |title=Active Thermal Control System (ATCS) Overview |url=https://www.nasa.gov/pdf/473486main_iss_atcs_overview.pdf |website=NASA}}</ref> maintains an equilibrium when the ISS environment or heat loads exceed the capabilities of the Passive Thermal Control System (PTCS). Note Elements of the PTCS are external surface materials, insulation such as [[Multi-layer insulation|Multi-Layer Insulation]] (MLI), or [[Heat pipe|Heat Pipes]]. The EATCS provides [[heat rejection]] capabilities for all the U.S. pressurized modules, the [[Kibo (ISS module)|Japanese Experiment Module]] (JEM), the [[Columbus (ISS module)|Columbus Orbital Facility]] (COF), and the main power distribution electronics of the [[Integrated Truss Structure#S0 truss|S0]], [[Integrated Truss Structure#P1.2C S1 trusses|S1]] and [[Integrated Truss Structure#P1.2C S1 trusses|P1]] Trusses. The EATCS consists of two independent Loops (Loop A & Loop B), which both use mechanically pumped fluid state [[ammonia]] in closed-loop circuits. The EATCS is capable of rejecting up to 70&nbsp;kW, and provides a substantial upgrade in heat rejection capacity from the 14&nbsp;kW capability of the Early External Active Thermal Control System (EEATCS) via the Early Ammonia Servicer (EAS), which was launched on [[STS-105]] and installed onto the [[Integrated Truss Structure#P6.2C S6 trusses|P6]] Truss.<ref name="iss_atcs_overview"/>


There are two independent Loops (Loop A & Loop B) that combined make up the EATCS. The EATCS Loops perform three primary functions:
There are two independent Loops (Loop A & Loop B) that combined make up the EATCS. The EATCS Loops perform three primary functions:


* Heat Collection - Each Loop draws heat from five Heat Exchangers (HXs) mounted on the Destiny Laboratory, Node-2 & Node-3 as well as cold plates under three DDCUs (one DDCU each on each Loop on the P1/S1 Trusses and two DDCUs each on each Loop on the S0 Truss) and two MBSUs on each Loop on the S0 Truss (see schematic below and [[Orbital Replacement Unit]]s (ORUs) for design of these units);
* Heat Collection - Each Loop draws heat from five Heat Exchangers (HXs) mounted on the [[Destiny (ISS module)|Destiny Laboratory]], [[Harmony (ISS module)|Node-2]] & [[Tranquility (ISS module)|Node-3]] as well as cold plates under three DC-to-DC Conversion Units (DDCUs) (one DDCU each on each Loop on the P1/S1 Trusses and two DDCUs each on each Loop on the S0 Truss) and two Main Bus Switching Units (MBSUs) on each Loop on the S0 Truss (see schematic below and [[Orbital Replacement Unit]]s (ORUs) for design of these units);
* Heat Transportation - The Pump Module (PM) provides flow and accumulator functions and maintains proper temperature control at the pump outlet for each Loop. The PM consists of a single pump, a fixed charge accumulator, a Pump & Control Valve Package (PCVP) containing a firmware controller, startup heaters, [[isolation valve]]s, and various sensors for monitoring performance. The Nitrogen Tank Assembly (NTA) controls the flow of ammonia out of the Ammonia Tank Assembly (ATA). The ATA contains two flexible, chambers incorporated into its ammonia tanks that expand as pressurized nitrogen from the NTA expels liquid ammonia out of the ATA. The major components in the ATA include two ammonia storage tanks, isolation valves, heaters, and various temperature, pressure, and quantity sensors;
* Heat Transportation - The Pump Module (PM) provides flow and accumulator functions and maintains proper temperature control at the pump outlet for each Loop. The PM consists of a single pump, a fixed charge accumulator, a Pump & Control Valve Package (PCVP) containing a firmware controller, startup heaters, [[isolation valve]]s, and various sensors for monitoring performance. The Nitrogen Tank Assembly (NTA) controls the flow of ammonia out of the Ammonia Tank Assembly (ATA). The ATA contains two flexible, chambers incorporated into its ammonia tanks that expand as pressurized nitrogen from the NTA expels liquid ammonia out of the ATA. The major components in the ATA include two ammonia storage tanks, isolation valves, heaters, and various temperature, pressure, and quantity sensors;
* Heat Rejection - Ammonia passes from the ATA through a two way path of the Flex Hose Rotary Coupler (FHRC) where heat captured while passing through the Heat Exchangers is directed to be expelled through the Heat Rejection System Radiators (HRSRs). The radiators are rotated by the Thermal Rotary Radiator Joint (TRRJ) which continually rotates the radiator wing for optimum cooling.
* Heat Rejection - Ammonia passes from the ATA through a two way path of the Flex Hose Rotary Coupler (FHRC) where heat captured while passing through the Heat Exchangers is directed to be expelled through the Heat Rejection System Radiators (HRSRs). The radiators are rotated by the Thermal Rotary Radiator Joint (TRRJ) which continually rotates the radiator wing for optimum cooling.
[[File:EATCS Overview.png|thumb|center|600px|EATCS schematic overview]]
[[File:EATCS Overview.png|thumb|center|600px|EATCS schematic overview]]


<center>
<gallery class="center">
<gallery>
File:02 PM on thr LMC for STS-131 2010-2215.jpg|Pump Module (PM)
File:02 PM on thr LMC for STS-131 2010-2215.jpg|Pump Module (PM)
File:Pump Module with fixed grapple bar and MLI illustrations.png|PM drawing
File:Pump Module with fixed grapple bar and MLI illustrations.png|PM drawing
Line 20: Line 20:
File:ATA.png|ATA drawing (cover removed)
File:ATA.png|ATA drawing (cover removed)
</gallery>
</gallery>
</center>


<center>
<gallery class="center">
<gallery>
File:01 FHRC sts126 fhrc.jpg|Flex Hose Rotary Coupler (FHRC)
File:01 FHRC sts126 fhrc.jpg|Flex Hose Rotary Coupler (FHRC)
File:FHRC without MLI cover STS-128.png|FHRC without MLI cover and in situ on the TRRJ
File:FHRC without MLI cover STS-128.png|FHRC without MLI cover and in situ on the TRRJ
Line 29: Line 27:
File:HRS.png|HRSR drawing
File:HRS.png|HRSR drawing
</gallery>
</gallery>
</center>
[[File:06 S1 Trruss.jpg|thumb|center|500px|EATCS components on the S1/P1 Trusses]]
[[File:06 S1 Trruss.jpg|thumb|center|500px|EATCS components on the S1/P1 Trusses]]
[[File:International_Space_Station_TCS.png|thumb|center|500px|TCS System of the ISS]]
[[File:International_Space_Station_TCS.png|thumb|center|500px|TCS System of the ISS]]

Latest revision as of 01:24, 6 May 2022

ISS External Active Thermal Control System (EATCS) diagram
Early Ammonia Servicer
DDCU cold plate design

The International Space Station (ISS) External Active Thermal Control System (EATCS)[1] maintains an equilibrium when the ISS environment or heat loads exceed the capabilities of the Passive Thermal Control System (PTCS). Note Elements of the PTCS are external surface materials, insulation such as Multi-Layer Insulation (MLI), or Heat Pipes. The EATCS provides heat rejection capabilities for all the U.S. pressurized modules, the Japanese Experiment Module (JEM), the Columbus Orbital Facility (COF), and the main power distribution electronics of the S0, S1 and P1 Trusses. The EATCS consists of two independent Loops (Loop A & Loop B), which both use mechanically pumped fluid state ammonia in closed-loop circuits. The EATCS is capable of rejecting up to 70 kW, and provides a substantial upgrade in heat rejection capacity from the 14 kW capability of the Early External Active Thermal Control System (EEATCS) via the Early Ammonia Servicer (EAS), which was launched on STS-105 and installed onto the P6 Truss.[1]

There are two independent Loops (Loop A & Loop B) that combined make up the EATCS. The EATCS Loops perform three primary functions:

  • Heat Collection - Each Loop draws heat from five Heat Exchangers (HXs) mounted on the Destiny Laboratory, Node-2 & Node-3 as well as cold plates under three DC-to-DC Conversion Units (DDCUs) (one DDCU each on each Loop on the P1/S1 Trusses and two DDCUs each on each Loop on the S0 Truss) and two Main Bus Switching Units (MBSUs) on each Loop on the S0 Truss (see schematic below and Orbital Replacement Units (ORUs) for design of these units);
  • Heat Transportation - The Pump Module (PM) provides flow and accumulator functions and maintains proper temperature control at the pump outlet for each Loop. The PM consists of a single pump, a fixed charge accumulator, a Pump & Control Valve Package (PCVP) containing a firmware controller, startup heaters, isolation valves, and various sensors for monitoring performance. The Nitrogen Tank Assembly (NTA) controls the flow of ammonia out of the Ammonia Tank Assembly (ATA). The ATA contains two flexible, chambers incorporated into its ammonia tanks that expand as pressurized nitrogen from the NTA expels liquid ammonia out of the ATA. The major components in the ATA include two ammonia storage tanks, isolation valves, heaters, and various temperature, pressure, and quantity sensors;
  • Heat Rejection - Ammonia passes from the ATA through a two way path of the Flex Hose Rotary Coupler (FHRC) where heat captured while passing through the Heat Exchangers is directed to be expelled through the Heat Rejection System Radiators (HRSRs). The radiators are rotated by the Thermal Rotary Radiator Joint (TRRJ) which continually rotates the radiator wing for optimum cooling.
EATCS schematic overview