Flicker fusion threshold: Difference between revisions
→Lighting: LEDs and high flicker frequencies |
m compound modifier |
||
(80 intermediate revisions by 45 users not shown) | |||
Line 1: | Line 1: | ||
{{short description|Concept in the psychophysics of vision}} |
|||
The '''flicker fusion threshold''' (or '''flicker fusion rate''') is a concept in the [[psychophysics]] of [[Visual perception|vision]]. It is defined as the frequency at which an intermittent light stimulus appears to be completely steady to the average human [[observation|observer]]. Flicker fusion threshold is related to [[persistence of vision]]. Although flicker can be detected for many waveforms representing time-variant fluctuations of intensity, it is conventionally, and most easily, studied in terms of sinusoidal modulation of intensity. There are seven parameters that determine the ability to detect the flicker: |
|||
The '''flicker fusion threshold''', also known as '''critical flicker frequency''' or '''flicker fusion rate''', is the frequency at which a [[Flicker (light)|flickering light]] appears steady to the average human observer. It is a concept studied in [[vision science]], more specifically in the [[psychophysics]] of [[visual perception]]. A traditional term for "flicker fusion" is "[[persistence of vision]]", but this has also been used to describe [[Afterimage#Positive afterimages|positive afterimages]] or [[motion blur]]. Although flicker can be detected for many waveforms representing time-variant fluctuations of intensity, it is conventionally, and most easily, studied in terms of sinusoidal modulation of intensity. |
|||
There are seven parameters that determine the ability to detect the flicker: |
|||
# the frequency of the modulation; |
# the frequency of the modulation; |
||
# the amplitude or depth of the modulation (i.e., what is the maximum percent decrease in the illumination intensity from its peak value); |
# the amplitude or depth of the modulation (i.e., what is the maximum percent decrease in the illumination intensity from its peak value); |
||
Line 7: | Line 10: | ||
# the position on the retina at which the stimulation occurs (due to the different distribution of photoreceptor types at different positions); |
# the position on the retina at which the stimulation occurs (due to the different distribution of photoreceptor types at different positions); |
||
# the degree of light or dark adaptation, i.e., the duration and intensity of previous exposure to background light, which affects both the intensity sensitivity and the time resolution of vision; |
# the degree of light or dark adaptation, i.e., the duration and intensity of previous exposure to background light, which affects both the intensity sensitivity and the time resolution of vision; |
||
# physiological factors such as age and fatigue.<ref>S.W. |
# physiological factors such as age and fatigue.<ref>{{cite journal|jstor=1418795|doi=10.2307/1418795|pmid=13275613|year=1955 |author1=Davis S. W. |title=Auditory and visual flickerfusion as measures of fatigue |journal=The American Journal of Psychology |volume=68 |issue=4 |pages=654–657 }}</ref> |
||
==Explanation== |
==Explanation== |
||
As long as the modulation frequency is kept above the fusion threshold, the perceived intensity can be changed by changing the relative periods of light and darkness. One can prolong the dark periods and thus darken the image; therefore the effective and average brightness are equal. This is known as the [[Talbot-Plateau law]].<ref name="eye">"eye, human."Encyclopædia Britannica. 2008. [[Encyclopædia Britannica 2006 Ultimate Reference Suite DVD]]</ref> Like all [[Psychophysics|psychophysical threshold]]s, the flicker fusion threshold is a statistical rather than an absolute quantity. There is a range of frequencies within which flicker sometimes will be seen and sometimes will not be seen, and the threshold is the frequency at which flicker is detected on 50% of trials. |
As long as the modulation frequency is kept above the fusion threshold, the perceived intensity can be changed by changing the relative periods of light and darkness. One can prolong the dark periods and thus darken the image; therefore the effective and average brightness are equal. This is known as the [[Talbot-Plateau law]].<ref name="eye">"eye, human." Encyclopædia Britannica. 2008. [[Encyclopædia Britannica 2006 Ultimate Reference Suite DVD]]</ref> Like all [[Psychophysics|psychophysical threshold]]s, the flicker fusion threshold is a statistical rather than an absolute quantity. There is a range of frequencies within which flicker sometimes will be seen and sometimes will not be seen, and the threshold is the frequency at which flicker is detected on 50% of trials. |
||
Different points in the visual system have very different critical flicker fusion rate (CFF) sensitivities; the overall threshold frequency for perception cannot exceed the slowest of these for a given modulation amplitude. |
Different points in the visual system have very different critical flicker fusion rate (CFF) sensitivities; the overall threshold frequency for perception cannot exceed the slowest of these for a given modulation amplitude. Each cell type integrates signals differently. For example, [[Rod cell|rod photoreceptor cells]], which are exquisitely sensitive and capable of single-photon detection, are very sluggish, with time constants in mammals of about 200 ms. [[Cone cell|Cones]], in contrast, while having much lower intensity sensitivity, have much better time resolution than rods do. For both rod- and cone-mediated vision, the fusion frequency increases as a function of illumination intensity, until it reaches a plateau corresponding to the maximal time resolution for each type of vision. The maximal fusion frequency for rod-mediated vision reaches a plateau at about 15 [[hertz]] (Hz), whereas cones reach a plateau, observable only at very high illumination intensities, of about 60 Hz.<ref>{{cite journal|pmid=19872976 |pmc=2141480 |doi=10.1085/jgp.19.6.965|title=Intermittent Stimulation by Light |year=1936 |last1=Hecht |first1=Selig |last2=Shlaer |first2=Simon |journal=Journal of General Physiology |volume=19 |issue=6 |pages=965–977 }}</ref><ref>{{cite web|url=http://www.bio.net/bionet/mm/neur-sci/2007-July/061925.html |title=[Neuroscience] Re: Flicker Fusion Threshold Examples |publisher=Bio.net |access-date=2013-05-05}}</ref> |
||
In addition to increasing with average illumination intensity, the fusion frequency also increases with the extent of modulation (the maximal relative decrease in light intensity presented); for each frequency and average illumination, there is a characteristic modulation threshold, below which the flicker cannot be detected, and for each modulation depth and average illumination, there is a characteristic frequency threshold. |
In addition to increasing with average illumination intensity, the fusion frequency also increases with the extent of modulation (the maximal relative decrease in light intensity presented); for each frequency and average illumination, there is a characteristic modulation threshold, below which the flicker cannot be detected, and for each modulation depth and average illumination, there is a characteristic frequency threshold. These values vary with the wavelength of illumination, because of the wavelength dependence of photoreceptor sensitivity, and they vary with the position of the illumination within the retina, because of the concentration of cones in central regions including the [[Fovea centralis|fovea]] and the [[macula]], and the dominance of rods in the peripheral regions of the retina. |
||
The flicker fusion threshold is proportional to the amount of [[amplitude modulation|modulation]]; if brightness is constant, a brief flicker will manifest a much lower threshold frequency than a long flicker. The threshold also varies with brightness (it is higher for a brighter light source) and with location on the [[retina]] where the perceived image falls: the [[rod cell]]s of the human eye have a faster response time than the [[cone cell]]s, so flicker can be sensed in [[peripheral vision]] at higher frequencies than in [[Fovea centralis|foveal]] vision. This is essentially the concept known as the Ferry-Porter law, where it may take some increase in brightness, by powers of ten, to require as many as 60 flashes to achieve fusion, while for rods, it may take as little as four flashes, since in the former case each flash is easily cut off, and in the latter it lasts long enough, even after 1/4 second, to merely prolong it and not intensify it.<ref name="eye"/> From a practical point of view, if a stimulus is flickering, such as computer monitor, decreasing the intensity level will eliminate the flicker.<ref>{{cite web|url=http://webvision.med.utah.edu/temporal.html |title=Temporal Resolution – Webvision |publisher=Webvision.med.utah.edu |date=2011-03-30 |accessdate=2013-05-05}}</ref> |
|||
The flicker fusion threshold also is lower for a fatigued observer. Decrease in the critical fusion frequency has often been used as an index of central fatigue.<ref>Ernst Simonson and Norbert Enzer, Measurement of fusion frequency of flicker as a test for fatigue of the central nervous system, J. Indus. Hyg. Tox., 23, 1941, 83–89.</ref> |
|||
== Technological considerations == |
== Technological considerations == |
||
===Display frame rate=== |
===Display frame rate=== |
||
Flicker fusion is important in all technologies for presenting moving images, nearly all of which depend on presenting a rapid succession of static images (e.g. the [[frame (film)|frame]]s in a cinema film, TV show, or a [[digital video]] file). If the [[frame rate]] falls below the flicker fusion threshold for the given viewing conditions, flicker will be apparent to the observer, and movements of objects on the film will appear jerky. For the purposes of presenting moving images, the human flicker fusion threshold is usually taken between 60 and 90 |
Flicker fusion is important in all technologies for presenting moving images, nearly all of which depend on presenting a rapid succession of static images (e.g. the [[frame (film)|frame]]s in a cinema film, TV show, or a [[digital video]] file). If the [[frame rate]] falls below the flicker fusion threshold for the given viewing conditions, flicker will be apparent to the observer, and movements of objects on the film will appear jerky. For the purposes of presenting moving images, the human flicker fusion threshold is usually taken between 60 and 90 Hz, though in certain cases it can be higher by an order of magnitude.<ref>{{citation |pmc=4314649 |title=Humans perceive flicker artefacts at 500 Hz |author=Davis, James |year=2015 |pmid=25644611 |doi=10.1038/srep07861 |volume=5 |journal=Sci Rep |pages=7861|bibcode=2015NatSR...5E7861D }}</ref> In practice, movies since the [[silent era]] are recorded at 24 frames per second and displayed by interrupting each frame two or three times for a flicker of 48 or 72 Hz. Television typically originates at 50 or 60 frames or interlaced [[Field (video)|fields]] per second. |
||
The flicker fusion threshold does not prevent indirect detection of a high frame rate, such as the phantom array effect or [[wagon-wheel effect]], as human-visible side effects of a finite frame rate were still seen on an experimental 480 Hz display.<ref>{{Cite web|url=https://www.blurbusters.com/4k-120hz-with-bonus-240hz-and-480hz-modes/|title=Test Results of an Experimental 480 Hz Display|last=Rejhon|first=Mark|website=Blur Busters|date=August 16, 2017}}</ref> |
|||
===Display refresh rate=== |
===Display refresh rate=== |
||
{{main|Flicker (screen)}} |
|||
[[Cathode |
[[Cathode-ray tube]] (CRT) displays typically operated at a [[vertical scan rate]] of 60 Hz, the same as [[Standard-definition television|SDTV]] content they displayed, which resulted in noticeable flicker. The same was true of other impulsed technologies such as [[plasma display]]s. Some systems could increase refresh rate to higher values such as 72, 75, 100, or 120 Hz to ease this problem, though even if the faster refresh is an integer multiple of the source material framerate to eliminate [[judder]], without higher framerate source material this causes the perception of duplicate images.<ref>{{Cite web|url=https://blurbusters.com/faq/advanced-strobe-crosstalk-faq/ |
||
|title=Strobe Crosstalk: Blur Reduction Double-Images|website=Blur Busters|access-date=2024-02-01}}</ref> Any flicker on [[sample and hold]] technologies such as [[Liquid-crystal display|LCD]] or [[OLED]], is unrelated to refresh rate and far less conspicuous, instead coming from incidental design compromises such as [[fluorescent]] backlights, [[Pulse-width modulation|PWM]] dimming, or [[temporal dithering]], all of which are eliminated on some devices that do not flicker at all. Because of the resulting [[display motion blur]] inherent to sample and hold screens, in applications where accurate [[motion perception]] is prioritized over user fatigue, the correct type of flicker can be reintroduced through techniques such as backlight strobing or black frame insertion. |
|||
Other display technologies do not flicker noticeably, so the frame rate is less important. [[LCD]] flat panels do not ''seem'' to flicker at all, as the backlight of the screen operates at a very high frequency of nearly 200 Hz, and each pixel is changed on a scan rather than briefly turning on and then off as in CRT displays. However, the nature of the back-lighting used can induce flicker – LEDs cannot be easily dimmed, and therefore use [[pulse-width modulation]] to create the illusion of dimming, and the frequency used can be perceived as flicker by sensitive users.<ref>{{cite web|url=http://crispycromar.com/psa-led-backlighting-can-cause-migraine-headaches/ |title=PSA: LED-Backlighting Can Cause Migraine Headaches |publisher=CrispyCromar.com |date= |accessdate=2013-05-05}}</ref><ref>{{cite web|author=View: Everyone Only Notes |url=https://discussions.apple.com/thread/1677617?threadID=1677617&tstart=0 |title=Eye strain from LED backlighting in...: Apple Support Communities |publisher=Discussions.apple.com |date=2008-08-23 |accessdate=2013-05-05}}</ref><ref>{{cite web|author=Wilkins, Veitch & Lehman|url=http://www.essex.ac.uk/psychology/overlays/2010-195.pdf |title=LED Lighting Flicker and Potential Health Concerns: IEEE Standard PAR1789 Update |publisher=University of Essex, UK |date=2010 |accessdate=2014-07-01}}</ref> |
|||
===Lighting=== |
===Lighting=== |
||
Flicker is also important in the field of domestic ([[alternating current]]) lighting, where noticeable flicker can be caused by varying electrical loads, and hence can be very disturbing to electric utility customers. Most electricity providers have maximum flicker limits that they try to meet for domestic customers. |
Flicker is also important in the field of domestic ([[alternating current]]) lighting, where noticeable flicker can be caused by varying electrical loads, and hence can be very disturbing to electric utility customers. Most electricity providers have maximum flicker limits that they try to meet for domestic customers. |
||
[[Fluorescent lamp]]s using conventional [[electrical ballast|magnetic ballasts]] flicker at twice the supply frequency. Electronic ballasts do not produce light flicker since the phosphor persistence is longer than a half cycle of the higher operation frequency of 20 kHz. The 100–120 Hz flicker produced by magnetic ballasts is associated with headaches and eyestrain.<ref> |
[[Fluorescent lamp]]s using conventional [[electrical ballast|magnetic ballasts]] flicker at twice the supply frequency. Electronic ballasts do not produce light flicker since the phosphor persistence is longer than a half cycle of the higher operation frequency of 20 kHz. The 100–120 Hz flicker produced by magnetic ballasts is associated with headaches and eyestrain.<ref> |
||
{{cite |
{{cite journal |
||
| title = Full-spectrum Fluorescent lighting : A review of its effects on physiology and health |
| title = Full-spectrum Fluorescent lighting : A review of its effects on physiology and health |
||
| url = http://journals.cambridge.org/action/displayAbstract?fromPage=online&aid=81689 |
|year = 2001|doi = 10.1017/S0033291701004251| url = http://journals.cambridge.org/action/displayAbstract?fromPage=online&aid=81689 |
||
| access-date = 2008-04-23 |journal = Psychological Medicine|volume = 31|issue = 6|pages = 949–964|pmid = 11513381|s2cid = 1105717| last1=l. Mccoll | first1=Shelley | last2=a. Veitch | first2=Jennifer }}</ref> |
|||
| accessdate = 2008-04-23 }}</ref> |
|||
Individuals with high critical flicker fusion threshold are particularly affected by light from fluorescent fixtures that have magnetic ballasts: their EEG alpha waves are markedly attenuated and they perform office tasks with greater speed and decreased accuracy. The problems are not observed with electronic ballasts.<ref>{{cite journal |journal= Ergonomics |volume=41 |issue=4 |pages=433–47 |year=1998 |title= The impact of flicker from fluorescent lighting on well-being, performance and physiological arousal |vauthors=Küller R, Laike T |doi= 10.1080/001401398186928 |pmid= 9557586}}</ref> Ordinary people have better reading performance using high-frequency (20–60 kHz) electronic ballasts than magnetic ballasts,<ref>{{cite journal |journal= Light Res Tech |volume=27 |issue=4 |year=1995 |pages=243–256 |url=http://www.nrc-cnrc.gc.ca/obj/irc/doc/pubs/nrcc38944/nrcc38944.pdf | |
Individuals with high critical flicker fusion threshold are particularly affected by light from fluorescent fixtures that have magnetic ballasts: their EEG alpha waves are markedly attenuated and they perform office tasks with greater speed and decreased accuracy. The problems are not observed with electronic ballasts.<ref>{{cite journal |journal= Ergonomics |volume=41 |issue=4 |pages=433–47 |year=1998 |title= The impact of flicker from fluorescent lighting on well-being, performance and physiological arousal |vauthors=Küller R, Laike T |doi= 10.1080/001401398186928 |pmid= 9557586}}</ref> Ordinary people have better reading performance using high-frequency (20–60 kHz) electronic ballasts than magnetic ballasts,<ref>{{cite journal |journal= Light Res Tech |volume=27 |issue=4 |year=1995 |pages=243–256 |url=http://www.nrc-cnrc.gc.ca/obj/irc/doc/pubs/nrcc38944/nrcc38944.pdf |access-date=2012-06-28 |vauthors=Veitch JA, McColl SL |title= Modulation of fluorescent light: flicker rate and light source effects on visual performance and visual comfort |doi= 10.1177/14771535950270040301|s2cid=36983942 }}</ref> although the effect was small except at high contrast ratio. |
||
The flicker of fluorescent lamps, even with magnetic ballasts, is so rapid that it is unlikely to present a hazard to individuals with [[epilepsy]].<ref>{{cite journal |journal=Epilepsia |year=1979 |volume=20 |issue=6 |pages=725–7 |title= Fluorescent lighting and epilepsy |vauthors=Binnie CD, de Korte RA, Wisman T |pmid=499117 |doi=10.1111/j.1528-1157.1979.tb04856.x}}</ref> Early studies suspected a relationship between the flickering of fluorescent lamps with magnetic ballasts and [[Stereotypy (psychiatry)|repetitive movement]] in [[autistic]] children.<ref>{{cite journal |journal= J Autism Child Schizophr |year=1976 |volume=6 |issue=2 |pages=157–62 |title= The effects of fluorescent and incandescent illumination upon repetitive behaviors in autistic children |vauthors=Colman RS, Frankel F, Ritvo E, Freeman BJ |doi=10.1007/BF01538059 |pmid=989489}}</ref> However, these studies had interpretive problems<ref>{{cite journal |journal= J Child Psychol Psychiatry |year=1999 |volume=40 |issue=6 |pages=839–49 |title= Annotation: Repetitive behaviour in autism: a review of psychological research |author= Turner M |pmid=10509879 |doi= 10.1017/S0021963099004278}}</ref> and have not been replicated. |
The flicker of fluorescent lamps, even with magnetic ballasts, is so rapid that it is unlikely to present a hazard to individuals with [[epilepsy]].<ref>{{cite journal |journal=Epilepsia |year=1979 |volume=20 |issue=6 |pages=725–7 |title= Fluorescent lighting and epilepsy |vauthors=Binnie CD, de Korte RA, Wisman T |pmid=499117 |doi=10.1111/j.1528-1157.1979.tb04856.x|s2cid=26527159 }}</ref> Early studies suspected a relationship between the flickering of fluorescent lamps with magnetic ballasts and [[Stereotypy (psychiatry)|repetitive movement]] in [[autistic]] children.<ref>{{cite journal |journal= J Autism Child Schizophr |year=1976 |volume=6 |issue=2 |pages=157–62 |title= The effects of fluorescent and incandescent illumination upon repetitive behaviors in autistic children |vauthors=Colman RS, Frankel F, Ritvo E, Freeman BJ |doi=10.1007/BF01538059 |pmid=989489|s2cid=41749390 }}</ref> However, these studies had interpretive problems<ref>{{cite journal |journal= J Child Psychol Psychiatry |year=1999 |volume=40 |issue=6 |pages=839–49 |title= Annotation: Repetitive behaviour in autism: a review of psychological research |author= Turner M |pmid=10509879 |doi= 10.1017/S0021963099004278}}</ref> and have not been replicated. |
||
LED lamps generally do not benefit from flicker attenuation through phosphor persistence, the notable exception being white LEDs. Flicker at frequencies as high as |
LED lamps generally do not benefit from flicker attenuation through phosphor persistence, the notable exception being white LEDs. Flicker at frequencies as high as 2000 Hz (2 kHz) can be perceived by humans during [[saccades]],<ref> |
||
{{cite journal |vauthors=Roberts JE, Wilkins AJ |year=2013 |title=Flicker can be perceived during saccades at frequencies in excess of 1 kHz |journal=[[Lighting Research & Technology]] |volume=45 |pages=124–132 |doi=10.1177/1477153512436367 |s2cid=51247933 |number=1}} |
|||
⚫ | |||
⚫ | |||
|vauthors=Roberts JE, Wilkins AJ |
|||
|title=Flicker can be perceived during saccades at frequencies in excess of 1 kHz |
|||
|journal=Lighting Research & Technology |
|||
|volume=45 |
|||
|number=1 |
|||
|pages=124-132 |
|||
|year=2013 |
|||
|doi=10.1177/1477153512436367}} |
|||
⚫ | |||
{{cite journal |
{{cite journal |
||
|vauthors=Lehman B, Wilkins AJ |
|vauthors=Lehman B, Wilkins AJ |
||
|volume=2014 |
|volume=2014 |
||
|number= |
|number=9 |
||
|pages= |
|pages=18–26 |
||
|title=Designing to Mitigate Effects of Flicker in LED Lighting: Reducing risks to health and safety |
|title=Designing to Mitigate Effects of Flicker in LED Lighting: Reducing risks to health and safety |
||
|journal=Power Electronics Magazine |
|journal=IEEE Power Electronics Magazine |
||
|doi=10.1109/MPEL.2014.2330442 |
|doi=10.1109/MPEL.2014.2330442|year=2014 |
||
|s2cid=2503129 |
|||
⚫ | |||
⚫ | |||
⚫ | |||
== Visual phenomena == |
== Visual phenomena == |
||
In some cases, it is possible to see flicker at rates beyond 2 kHz in the case of high-speed eye movements ([[saccade |
In some cases, it is possible to see flicker at rates beyond 2000 Hz (2 kHz) in the case of high-speed eye movements ([[saccade]]s) or object motion, via the "phantom array" effect.<ref>Wilkins, A. J. (2014) [https://efiling.energy.ca.gov/GetDocument.aspx?tn=74074&DocumentContentId=13126 Energy - Docket Optical System]. energy.ca.gov</ref><ref>{{cite journal|doi=10.1177/1477153512436367|title=Flicker can be perceived during saccades at frequencies in excess of 1 k ''Hz'' |year=2013 |last1=Roberts |first1=JE |last2=Wilkins |first2=AJ |journal=Lighting Research & Technology |volume=45 |pages=124–132 |s2cid=51247933 }}</ref> Fast-moving flickering objects zooming across view (either by object motion, or by eye motion such as rolling eyes), can cause a dotted or multicolored blur instead of a continuous blur, as if they were multiple objects.<ref>[http://www.thenakedscientists.com/forum/index.php?topic=45126.0 Why do LED tail lights trail to me and not to the rest of my family?] The Naked Scientists (August 2012)</ref> [[Stroboscope]]s are sometimes used to induce this effect intentionally. |
||
Some special effects, such as certain kinds of [[glowsticking|electronic glowsticks]] commonly seen at outdoor events, have the appearance of a solid color when motionless but produce a multicolored or dotted blur when waved about in motion. These are typically LED-based glow sticks. The variation of the duty cycle upon the LED(s), results in usage of less power while by the properties of flicker fusion having the direct effect of varying the brightness.{{Citation needed|date=April 2009}} When moved, if the frequency of duty cycle of the driven LED(s) is below the flicker fusion threshold timing differences between the on/off state of the LED(s) becomes evident, and the color(s) appear as evenly spaced points in the peripheral vision. |
Some special effects, such as certain kinds of [[glowsticking|electronic glowsticks]] commonly seen at outdoor events, have the appearance of a solid color when motionless but produce a multicolored or dotted blur when waved about in motion. These are typically LED-based glow sticks. The variation of the duty cycle upon the LED(s), results in usage of less power while by the properties of flicker fusion having the direct effect of varying the brightness.{{Citation needed|date=April 2009}} When moved, if the frequency of duty cycle of the driven LED(s) is below the flicker fusion threshold timing differences between the on/off state of the LED(s) becomes evident, and the color(s) appear as evenly spaced points in the peripheral vision. |
||
A related phenomenon is the [[ |
A related phenomenon is the [[rainbow effect]], where different colors are displayed in different places on the screen for the same object due to fast motion. |
||
===Flicker=== |
|||
The [[stroboscopic effect]] is sometimes used to "stop motion" or to study small differences in repetitive motions. |
|||
''[[Flicker (light)|Flicker]]'' is the perception of visual fluctuations in intensity and unsteadiness in the presence of a light stimulus, that is seen by a static observer within a static environment. Flicker that is visible to the human eye will operate at a frequency of up to 80 Hz.<ref name=r1>{{cite web|url=https://unios.com/wp-content/uploads/2019/02/UN_Driving-the-Flicker-Free-Effect_White-Paper-190205.pdf |title=Driving the Flicker-Free Effect |publisher=Unios Australia|date=2019-02-05|access-date=2019-02-08 }}</ref> |
|||
===Stroboscopic effect=== |
|||
The ''[[stroboscopic effect]]'' is sometimes used to "stop motion" or to study small differences in repetitive motions. The stroboscopic effect refers to the phenomenon that occurs when there is a change in perception of motion, caused by a light stimulus that is seen by a static observer within a dynamic environment. The stroboscopic effect will typically occur within a frequency range between 80 and 2000 Hz,<ref name=r1/> though can go well beyond to 10,000 Hz for a percentage of population.<ref>{{Cite journal|url=https://www.lrc.rpi.edu/programs/solidstate/assist/pdf/AR-Flicker.pdf#page=6|title=Flicker Parameters for Reducing Stroboscopic Effects from Solid-state Lighting Systems|publisher=Lighting Research Center|year=2012|journal=Alliance for Solid-State Illumination Systems and Technologies (ASSIST)|pages=6|volume =11|issue =1}}</ref> |
|||
===Phantom array=== |
|||
'''Phantom array''', also known as the '''ghosting effect''', occurs when there is a change in perception of shapes and spatial positions of objects. The phenomenon is caused by a light stimulus in combination with rapid eye movements (saccades) of an observer in a static environment. Similar to the stroboscopic effect, the phantom effect will also occur at similar frequency ranges. The mouse arrow is a common example<ref>{{Cite web|url=https://www.testufo.com/mousearrow|title=TestUFO: Animation Of Phantom Array Effect With Mouse Arrow|website=www.testufo.com|access-date=2019-05-20}}</ref> of the phantom array effect. |
|||
==Non-human species== |
==Non-human species== |
||
The flicker fusion threshold also varies between [[species]]. |
The flicker fusion threshold also varies between [[species]]. A 2014 survey of the critical fusion frequency in animals found the lowest value (6.7 Hz) in the cane toad (''Bufo marinus'') and the highest value (400 Hz) in the black fire beetle (''Melanophila acuminate'').<ref name="Inger2014">{{cite journal |last1=Inger |first1=R. |last2=Bennie |first2=J. |last3=Davies |first3=T.W. |last4=Gaston |first4=K.J. |title=Potential Biological and ecological effects of flickering artificial light |journal=PLOS ONE |date=29 May 2014 |volume=9 |issue=5 |pages=e98631 |doi=10.1371/journal.pone.0098631|doi-access=free |bibcode=2014PLoSO...998631I |hdl=10871/21221 |hdl-access=free }}</ref> Estimates for different species of bird vary from 40 Hz to 140 Hz, with higher values tending to be associated with faster-moving species.<ref>{{cite journal |last1=Potier |first1=S. |last2=Lieuvin |first2=M. |last3=Pfaff |first3=M. |last4=Kelber |first4=A. |title=How fast can raptors see? |journal=Journal of Experimental Biology |date=1 January 2019 |volume=223 |issue=Pt 1 |doi=10.1242/jeb.209031|pmid=31822552 }}</ref> Many mammals have a higher proportion of rods in their retina than humans do, and it is likely that they would also have higher flicker fusion thresholds. This has been confirmed in dogs.<ref>{{cite web|url=http://onpoint.wbur.org/2009/09/22/a-dogs-eye-view |title=A Dog's Eye View | On Point with Tom Ashbrook |publisher=Onpoint.wbur.org |access-date=2013-05-05 |url-status=dead |archive-url=https://web.archive.org/web/20131020162644/http://onpoint.wbur.org/2009/09/22/a-dogs-eye-view |archive-date=October 20, 2013 }}</ref> |
||
If artificial lighting is perceived as flickering by some animals, the aversive effect might be an issue for animal welfare and conservation. However, those animals most liable to perceive flicker tend to be diurnal species active in bright light, and thus least likely to be exposed to artificial lighting outside of captivity.<ref name="Inger2014"/> Size and metabolic rate are two further factors associated with the variation in flicker fusion thresholds: small animals with a high metabolic rate tend to have high values.<ref>{{cite journal|title=Metabolic rate and body size linked with perception of temporal information |journal=Animal Behaviour |publisher=Elsevier|date= 2013-10-01|volume=86 |issue=4 |pages=685–696 |doi=10.1016/j.anbehav.2013.06.018 |pmid=24109147 |pmc=3791410 |last1=Healy |first1=Kevin |last2=McNally |first2=Luke |last3=Ruxton |first3=Graeme D. |last4=Cooper |first4=Natalie |last5=Jackson |first5=Andrew L. }}</ref><ref>{{cite news|newspaper=The Economist |url=https://www.economist.com/news/science-and-technology/21586532-small-creatures-fast-metabolisms-see-world-action-replay-slo-mo |title=Slo-mo mojo: How animals perceive time|date= 2013-09-21|access-date=2013-10-20 | location=London}}</ref> |
|||
==See also== |
==See also== |
||
⚫ | |||
* [[CDR Computerized Assessment System]] |
|||
* [[CDR computerized assessment system]] |
|||
* [[Frame rate]] |
|||
* [[Persistence of vision]] |
* [[Persistence of vision]] |
||
* [[Refresh rate]] |
|||
* [[Tweening]] |
* [[Tweening]] |
||
⚫ | |||
==References== |
==References== |
||
{{reflist}} |
{{reflist}} |
||
{{refbegin}} |
|||
⚫ | |||
* {{Cite news |
|||
⚫ | |||
| last = Winkler |
|||
| first = Robert |
|||
| title = The Need for Speed |
|||
| work = The New York Times |
|||
| date = 2005-11-13 |
|||
| url = https://www.nytimes.com/2005/11/13/opinion/nyregionopinions/13WEwinkler.html |
|||
⚫ | |||
** {{cite web |
|||
| title = The Flicker Fusion Factor: Why we can't drive safely at high speed |
| title = The Flicker Fusion Factor: Why we can't drive safely at high speed |
||
| first = Robert |
| first = Robert |
||
| last = Winkler |
| last = Winkler |
||
| url = http://pages.cthome.net/rwinkler/fff.htm |
| url = http://pages.cthome.net/rwinkler/fff.htm |
||
| |
| archive-url = https://web.archive.org/web/20101205102051/http://pages.cthome.net/rwinkler/fff.htm |
||
| |
| archive-date = 2010-12-05 |
||
| postscript =, repost on author's personal website. |
| postscript =, repost on author's personal website. |
||
}} |
}} |
||
* {{Cite web |url=http://scienceblogs.com/pharyngula/2006/11/i_get_it_i_know_im_inferior.php |title=I get it, I know I'm inferior{{Snd}} comments |date=November 9, 2006 |website=Science Blogs{{Snd}} Pharyngula |archive-url=https://web.archive.org/web/20081230180628/http://scienceblogs.com/pharyngula/2006/11/i_get_it_i_know_im_inferior.php |archive-date=2008-12-30 }}*[https://web.archive.org/web/20071008215757/http://www.enernex.com/staff/docs/FlickerPQA2004.pdf IEC Flicker Meter (PDF)] |
|||
{{refend}} |
|||
⚫ | |||
*[https://web.archive.org/web/20071008215757/http://www.enernex.com/staff/docs/FlickerPQA2004.pdf IEC Flicker Meter] |
|||
*[https://web.archive.org/web/20101205102051/http://pages.cthome.net/rwinkler/fff.htm The Flicker Fusion Factor] Why we can't drive safely at high speed |
*[https://web.archive.org/web/20101205102051/http://pages.cthome.net/rwinkler/fff.htm The Flicker Fusion Factor] Why we can't drive safely at high speed |
||
*[http://webvision.med.utah.edu/temporal.html Webvision |
*[https://web.archive.org/web/20110318000647/http://webvision.med.utah.edu/temporal.html Webvision.med.utah.edu section concerning the psychophysics of time in vision] |
||
([[Wayback Machine]] copies) |
|||
[[Category:Vision]] |
[[Category:Vision]] |
Latest revision as of 16:12, 25 October 2024
The flicker fusion threshold, also known as critical flicker frequency or flicker fusion rate, is the frequency at which a flickering light appears steady to the average human observer. It is a concept studied in vision science, more specifically in the psychophysics of visual perception. A traditional term for "flicker fusion" is "persistence of vision", but this has also been used to describe positive afterimages or motion blur. Although flicker can be detected for many waveforms representing time-variant fluctuations of intensity, it is conventionally, and most easily, studied in terms of sinusoidal modulation of intensity.
There are seven parameters that determine the ability to detect the flicker:
- the frequency of the modulation;
- the amplitude or depth of the modulation (i.e., what is the maximum percent decrease in the illumination intensity from its peak value);
- the average (or maximum—these can be inter-converted if modulation depth is known) illumination intensity;
- the wavelength (or wavelength range) of the illumination (this parameter and the illumination intensity can be combined into a single parameter for humans or other animals for which the sensitivities of rods and cones are known as a function of wavelength using the luminous flux function);
- the position on the retina at which the stimulation occurs (due to the different distribution of photoreceptor types at different positions);
- the degree of light or dark adaptation, i.e., the duration and intensity of previous exposure to background light, which affects both the intensity sensitivity and the time resolution of vision;
- physiological factors such as age and fatigue.[1]
Explanation
[edit]As long as the modulation frequency is kept above the fusion threshold, the perceived intensity can be changed by changing the relative periods of light and darkness. One can prolong the dark periods and thus darken the image; therefore the effective and average brightness are equal. This is known as the Talbot-Plateau law.[2] Like all psychophysical thresholds, the flicker fusion threshold is a statistical rather than an absolute quantity. There is a range of frequencies within which flicker sometimes will be seen and sometimes will not be seen, and the threshold is the frequency at which flicker is detected on 50% of trials.
Different points in the visual system have very different critical flicker fusion rate (CFF) sensitivities; the overall threshold frequency for perception cannot exceed the slowest of these for a given modulation amplitude. Each cell type integrates signals differently. For example, rod photoreceptor cells, which are exquisitely sensitive and capable of single-photon detection, are very sluggish, with time constants in mammals of about 200 ms. Cones, in contrast, while having much lower intensity sensitivity, have much better time resolution than rods do. For both rod- and cone-mediated vision, the fusion frequency increases as a function of illumination intensity, until it reaches a plateau corresponding to the maximal time resolution for each type of vision. The maximal fusion frequency for rod-mediated vision reaches a plateau at about 15 hertz (Hz), whereas cones reach a plateau, observable only at very high illumination intensities, of about 60 Hz.[3][4]
In addition to increasing with average illumination intensity, the fusion frequency also increases with the extent of modulation (the maximal relative decrease in light intensity presented); for each frequency and average illumination, there is a characteristic modulation threshold, below which the flicker cannot be detected, and for each modulation depth and average illumination, there is a characteristic frequency threshold. These values vary with the wavelength of illumination, because of the wavelength dependence of photoreceptor sensitivity, and they vary with the position of the illumination within the retina, because of the concentration of cones in central regions including the fovea and the macula, and the dominance of rods in the peripheral regions of the retina.
Technological considerations
[edit]Display frame rate
[edit]Flicker fusion is important in all technologies for presenting moving images, nearly all of which depend on presenting a rapid succession of static images (e.g. the frames in a cinema film, TV show, or a digital video file). If the frame rate falls below the flicker fusion threshold for the given viewing conditions, flicker will be apparent to the observer, and movements of objects on the film will appear jerky. For the purposes of presenting moving images, the human flicker fusion threshold is usually taken between 60 and 90 Hz, though in certain cases it can be higher by an order of magnitude.[5] In practice, movies since the silent era are recorded at 24 frames per second and displayed by interrupting each frame two or three times for a flicker of 48 or 72 Hz. Television typically originates at 50 or 60 frames or interlaced fields per second.
The flicker fusion threshold does not prevent indirect detection of a high frame rate, such as the phantom array effect or wagon-wheel effect, as human-visible side effects of a finite frame rate were still seen on an experimental 480 Hz display.[6]
Display refresh rate
[edit]Cathode-ray tube (CRT) displays typically operated at a vertical scan rate of 60 Hz, the same as SDTV content they displayed, which resulted in noticeable flicker. The same was true of other impulsed technologies such as plasma displays. Some systems could increase refresh rate to higher values such as 72, 75, 100, or 120 Hz to ease this problem, though even if the faster refresh is an integer multiple of the source material framerate to eliminate judder, without higher framerate source material this causes the perception of duplicate images.[7] Any flicker on sample and hold technologies such as LCD or OLED, is unrelated to refresh rate and far less conspicuous, instead coming from incidental design compromises such as fluorescent backlights, PWM dimming, or temporal dithering, all of which are eliminated on some devices that do not flicker at all. Because of the resulting display motion blur inherent to sample and hold screens, in applications where accurate motion perception is prioritized over user fatigue, the correct type of flicker can be reintroduced through techniques such as backlight strobing or black frame insertion.
Lighting
[edit]Flicker is also important in the field of domestic (alternating current) lighting, where noticeable flicker can be caused by varying electrical loads, and hence can be very disturbing to electric utility customers. Most electricity providers have maximum flicker limits that they try to meet for domestic customers.
Fluorescent lamps using conventional magnetic ballasts flicker at twice the supply frequency. Electronic ballasts do not produce light flicker since the phosphor persistence is longer than a half cycle of the higher operation frequency of 20 kHz. The 100–120 Hz flicker produced by magnetic ballasts is associated with headaches and eyestrain.[8] Individuals with high critical flicker fusion threshold are particularly affected by light from fluorescent fixtures that have magnetic ballasts: their EEG alpha waves are markedly attenuated and they perform office tasks with greater speed and decreased accuracy. The problems are not observed with electronic ballasts.[9] Ordinary people have better reading performance using high-frequency (20–60 kHz) electronic ballasts than magnetic ballasts,[10] although the effect was small except at high contrast ratio.
The flicker of fluorescent lamps, even with magnetic ballasts, is so rapid that it is unlikely to present a hazard to individuals with epilepsy.[11] Early studies suspected a relationship between the flickering of fluorescent lamps with magnetic ballasts and repetitive movement in autistic children.[12] However, these studies had interpretive problems[13] and have not been replicated.
LED lamps generally do not benefit from flicker attenuation through phosphor persistence, the notable exception being white LEDs. Flicker at frequencies as high as 2000 Hz (2 kHz) can be perceived by humans during saccades,[14] and frequencies above 3000 Hz (3 kHz) have been recommended to avoid human biological effects.[15]
Visual phenomena
[edit]In some cases, it is possible to see flicker at rates beyond 2000 Hz (2 kHz) in the case of high-speed eye movements (saccades) or object motion, via the "phantom array" effect.[16][17] Fast-moving flickering objects zooming across view (either by object motion, or by eye motion such as rolling eyes), can cause a dotted or multicolored blur instead of a continuous blur, as if they were multiple objects.[18] Stroboscopes are sometimes used to induce this effect intentionally. Some special effects, such as certain kinds of electronic glowsticks commonly seen at outdoor events, have the appearance of a solid color when motionless but produce a multicolored or dotted blur when waved about in motion. These are typically LED-based glow sticks. The variation of the duty cycle upon the LED(s), results in usage of less power while by the properties of flicker fusion having the direct effect of varying the brightness.[citation needed] When moved, if the frequency of duty cycle of the driven LED(s) is below the flicker fusion threshold timing differences between the on/off state of the LED(s) becomes evident, and the color(s) appear as evenly spaced points in the peripheral vision.
A related phenomenon is the rainbow effect, where different colors are displayed in different places on the screen for the same object due to fast motion.
Flicker
[edit]Flicker is the perception of visual fluctuations in intensity and unsteadiness in the presence of a light stimulus, that is seen by a static observer within a static environment. Flicker that is visible to the human eye will operate at a frequency of up to 80 Hz.[19]
Stroboscopic effect
[edit]The stroboscopic effect is sometimes used to "stop motion" or to study small differences in repetitive motions. The stroboscopic effect refers to the phenomenon that occurs when there is a change in perception of motion, caused by a light stimulus that is seen by a static observer within a dynamic environment. The stroboscopic effect will typically occur within a frequency range between 80 and 2000 Hz,[19] though can go well beyond to 10,000 Hz for a percentage of population.[20]
Phantom array
[edit]Phantom array, also known as the ghosting effect, occurs when there is a change in perception of shapes and spatial positions of objects. The phenomenon is caused by a light stimulus in combination with rapid eye movements (saccades) of an observer in a static environment. Similar to the stroboscopic effect, the phantom effect will also occur at similar frequency ranges. The mouse arrow is a common example[21] of the phantom array effect.
Non-human species
[edit]The flicker fusion threshold also varies between species. A 2014 survey of the critical fusion frequency in animals found the lowest value (6.7 Hz) in the cane toad (Bufo marinus) and the highest value (400 Hz) in the black fire beetle (Melanophila acuminate).[22] Estimates for different species of bird vary from 40 Hz to 140 Hz, with higher values tending to be associated with faster-moving species.[23] Many mammals have a higher proportion of rods in their retina than humans do, and it is likely that they would also have higher flicker fusion thresholds. This has been confirmed in dogs.[24]
If artificial lighting is perceived as flickering by some animals, the aversive effect might be an issue for animal welfare and conservation. However, those animals most liable to perceive flicker tend to be diurnal species active in bright light, and thus least likely to be exposed to artificial lighting outside of captivity.[22] Size and metabolic rate are two further factors associated with the variation in flicker fusion thresholds: small animals with a high metabolic rate tend to have high values.[25][26]
See also
[edit]- Broca-Sulzer effect
- CDR computerized assessment system
- Frame rate
- Persistence of vision
- Refresh rate
- Tweening
References
[edit]- ^ Davis S. W. (1955). "Auditory and visual flickerfusion as measures of fatigue". The American Journal of Psychology. 68 (4): 654–657. doi:10.2307/1418795. JSTOR 1418795. PMID 13275613.
- ^ "eye, human." Encyclopædia Britannica. 2008. Encyclopædia Britannica 2006 Ultimate Reference Suite DVD
- ^ Hecht, Selig; Shlaer, Simon (1936). "Intermittent Stimulation by Light". Journal of General Physiology. 19 (6): 965–977. doi:10.1085/jgp.19.6.965. PMC 2141480. PMID 19872976.
- ^ "[Neuroscience] Re: Flicker Fusion Threshold Examples". Bio.net. Retrieved 2013-05-05.
- ^ Davis, James (2015), "Humans perceive flicker artefacts at 500 Hz", Sci Rep, 5: 7861, Bibcode:2015NatSR...5E7861D, doi:10.1038/srep07861, PMC 4314649, PMID 25644611
- ^ Rejhon, Mark (August 16, 2017). "Test Results of an Experimental 480 Hz Display". Blur Busters.
- ^ "Strobe Crosstalk: Blur Reduction Double-Images". Blur Busters. Retrieved 2024-02-01.
- ^ l. Mccoll, Shelley; a. Veitch, Jennifer (2001). "Full-spectrum Fluorescent lighting : A review of its effects on physiology and health". Psychological Medicine. 31 (6): 949–964. doi:10.1017/S0033291701004251. PMID 11513381. S2CID 1105717. Retrieved 2008-04-23.
- ^ Küller R, Laike T (1998). "The impact of flicker from fluorescent lighting on well-being, performance and physiological arousal". Ergonomics. 41 (4): 433–47. doi:10.1080/001401398186928. PMID 9557586.
- ^ Veitch JA, McColl SL (1995). "Modulation of fluorescent light: flicker rate and light source effects on visual performance and visual comfort" (PDF). Light Res Tech. 27 (4): 243–256. doi:10.1177/14771535950270040301. S2CID 36983942. Retrieved 2012-06-28.
- ^ Binnie CD, de Korte RA, Wisman T (1979). "Fluorescent lighting and epilepsy". Epilepsia. 20 (6): 725–7. doi:10.1111/j.1528-1157.1979.tb04856.x. PMID 499117. S2CID 26527159.
- ^ Colman RS, Frankel F, Ritvo E, Freeman BJ (1976). "The effects of fluorescent and incandescent illumination upon repetitive behaviors in autistic children". J Autism Child Schizophr. 6 (2): 157–62. doi:10.1007/BF01538059. PMID 989489. S2CID 41749390.
- ^ Turner M (1999). "Annotation: Repetitive behaviour in autism: a review of psychological research". J Child Psychol Psychiatry. 40 (6): 839–49. doi:10.1017/S0021963099004278. PMID 10509879.
- ^ Roberts JE, Wilkins AJ (2013). "Flicker can be perceived during saccades at frequencies in excess of 1 kHz". Lighting Research & Technology. 45 (1): 124–132. doi:10.1177/1477153512436367. S2CID 51247933.
- ^ Lehman B, Wilkins AJ (2014). "Designing to Mitigate Effects of Flicker in LED Lighting: Reducing risks to health and safety". IEEE Power Electronics Magazine. 2014 (9): 18–26. doi:10.1109/MPEL.2014.2330442. S2CID 2503129.
- ^ Wilkins, A. J. (2014) Energy - Docket Optical System. energy.ca.gov
- ^ Roberts, JE; Wilkins, AJ (2013). "Flicker can be perceived during saccades at frequencies in excess of 1 k Hz". Lighting Research & Technology. 45: 124–132. doi:10.1177/1477153512436367. S2CID 51247933.
- ^ Why do LED tail lights trail to me and not to the rest of my family? The Naked Scientists (August 2012)
- ^ a b "Driving the Flicker-Free Effect" (PDF). Unios Australia. 2019-02-05. Retrieved 2019-02-08.
- ^ "Flicker Parameters for Reducing Stroboscopic Effects from Solid-state Lighting Systems" (PDF). Alliance for Solid-State Illumination Systems and Technologies (ASSIST). 11 (1). Lighting Research Center: 6. 2012.
- ^ "TestUFO: Animation Of Phantom Array Effect With Mouse Arrow". www.testufo.com. Retrieved 2019-05-20.
- ^ a b Inger, R.; Bennie, J.; Davies, T.W.; Gaston, K.J. (29 May 2014). "Potential Biological and ecological effects of flickering artificial light". PLOS ONE. 9 (5): e98631. Bibcode:2014PLoSO...998631I. doi:10.1371/journal.pone.0098631. hdl:10871/21221.
- ^ Potier, S.; Lieuvin, M.; Pfaff, M.; Kelber, A. (1 January 2019). "How fast can raptors see?". Journal of Experimental Biology. 223 (Pt 1). doi:10.1242/jeb.209031. PMID 31822552.
- ^ "A Dog's Eye View | On Point with Tom Ashbrook". Onpoint.wbur.org. Archived from the original on October 20, 2013. Retrieved 2013-05-05.
- ^ Healy, Kevin; McNally, Luke; Ruxton, Graeme D.; Cooper, Natalie; Jackson, Andrew L. (2013-10-01). "Metabolic rate and body size linked with perception of temporal information". Animal Behaviour. 86 (4). Elsevier: 685–696. doi:10.1016/j.anbehav.2013.06.018. PMC 3791410. PMID 24109147.
- ^ "Slo-mo mojo: How animals perceive time". The Economist. London. 2013-09-21. Retrieved 2013-10-20.
External links
[edit]- Winkler, Robert. "The Flicker Fusion Factor: Why we can't drive safely at high speed". Archived from the original on 2010-12-05, repost on author's personal website.
{{cite web}}
: CS1 maint: postscript (link) - "I get it, I know I'm inferior – comments". Science Blogs – Pharyngula. November 9, 2006. Archived from the original on 2008-12-30.*IEC Flicker Meter (PDF)
- The Flicker Fusion Factor Why we can't drive safely at high speed
- Webvision.med.utah.edu section concerning the psychophysics of time in vision
(Wayback Machine copies)