Optode: Difference between revisions
m Added a few internal links from an online link suggesting tool. |
some cleanup |
||
Line 1: | Line 1: | ||
{{Orphan|November 2006}} |
{{Orphan|November 2006}} |
||
{{wikify|October 2006}} |
{{wikify|October 2006}} |
||
An ''' |
An '''optode''' or '''optrode''' is an optical sensor device that optically measures a specific substance usually with the aid of a chemical transducer. |
||
An |
An optode requires three components to function: a chemical that responds to an analyte, a polymer to immobilise the chemical transducer and instrumentation ([[Optical fiber|optical fibre]], [[Light|light source]], detector and other electronics). Optodes usually have the polymer matrix coated onto the distal tip of an optical fibre, but in the case of [[evanescent wave]] optodes the polymer is coated on a section of fibre that has been unsheathed. |
||
Optodes can apply various optical measurement schemes such as reflection, absorption, evansescent wave, luminescence (fluorescence and phosphorescences), chemiluminescence, [[Plasmon|surface plasmon]] resonance. By far the most popular methodology is luminescence. |
|||
Luminescence in solution obeys the [[Stern-Volmer relationship]]. This relationship is linear. Fluorescence of a molecule is quenched by specific analytes e.g. Ruthenium complexes are quenched by oxygen. When a fluorophore is immobilised within a polymer matrix a miriad of micro-environments are created. The micro-environments reflect varying diffusion co-efficients for the analyte. This leads to a [[Nonlinearity|non-linear]] relationship between the fluorescence and the quencher (analyte). This relationship is modelled in various ways, the most popular model is the Two site model created by James Demas (University of Virginia) |
Luminescence in solution obeys the [[Stern-Volmer relationship]]. This relationship is linear. Fluorescence of a molecule is quenched by specific analytes e.g. [[Ruthenium]] complexes are quenched by oxygen. When a fluorophore is immobilised within a polymer matrix a miriad of micro-environments are created. The micro-environments reflect varying diffusion co-efficients for the analyte. This leads to a [[Nonlinearity|non-linear]] relationship between the fluorescence and the quencher (analyte). This relationship is modelled in various ways, the most popular model is the Two site model created by James Demas (University of Virginia) |
||
The signal (fluorescence) to oxygen ratio is not linear, and an optode is most sensitive at low oxygen concentration, i.e. the sensitivity decreases as oxygen concentration increases. The optode sensors can however work in the whole region 0-100% [[oxygen saturation]] in water, and the calibration is done the same way as with the Clark type sensor. No oxygen is consumed and hence the sensor is stirring insensitive, but the signal will stabilize more quickly if |
The signal (fluorescence) to oxygen ratio is not linear, and an optode is most sensitive at low oxygen concentration, i.e. the sensitivity decreases as oxygen concentration increases. The optode sensors can however work in the whole region 0-100% [[oxygen saturation]] in water, and the calibration is done the same way as with the Clark type sensor. No oxygen is consumed and hence the sensor is stirring insensitive, but the signal will stabilize more quickly if the sensor is stirred after putting it into the sample. |
||
Optical sensors are growing in popularity due to the low-cost, low power requirements and long term stability. They provide viable alternatives to electrode |
Optical sensors are growing in popularity due to the low-cost, low power requirements and long term stability. They provide viable alternatives to electrode-based sensors or more complicated analytical instrumentation. |
||
Major international conferences are devoted to their development e.g Europtrode VIII Tubeingen 2006, OFS 18, Cancun 2006. |
Major international conferences are devoted to their development e.g Europtrode VIII Tubeingen 2006, OFS 18, Cancun 2006. |
||
Line 18: | Line 18: | ||
[[Category:Sensors]] |
[[Category:Sensors]] |
||
[[Category:Spectroscopy]] |
[[Category:Spectroscopy]] |
||
{{Tech-stub}} |
{{Tech-stub}} |
Revision as of 14:19, 28 March 2007
Template:Wikify is deprecated. Please use a more specific cleanup template as listed in the documentation. |
An optode or optrode is an optical sensor device that optically measures a specific substance usually with the aid of a chemical transducer.
An optode requires three components to function: a chemical that responds to an analyte, a polymer to immobilise the chemical transducer and instrumentation (optical fibre, light source, detector and other electronics). Optodes usually have the polymer matrix coated onto the distal tip of an optical fibre, but in the case of evanescent wave optodes the polymer is coated on a section of fibre that has been unsheathed.
Optodes can apply various optical measurement schemes such as reflection, absorption, evansescent wave, luminescence (fluorescence and phosphorescences), chemiluminescence, surface plasmon resonance. By far the most popular methodology is luminescence.
Luminescence in solution obeys the Stern-Volmer relationship. This relationship is linear. Fluorescence of a molecule is quenched by specific analytes e.g. Ruthenium complexes are quenched by oxygen. When a fluorophore is immobilised within a polymer matrix a miriad of micro-environments are created. The micro-environments reflect varying diffusion co-efficients for the analyte. This leads to a non-linear relationship between the fluorescence and the quencher (analyte). This relationship is modelled in various ways, the most popular model is the Two site model created by James Demas (University of Virginia)
The signal (fluorescence) to oxygen ratio is not linear, and an optode is most sensitive at low oxygen concentration, i.e. the sensitivity decreases as oxygen concentration increases. The optode sensors can however work in the whole region 0-100% oxygen saturation in water, and the calibration is done the same way as with the Clark type sensor. No oxygen is consumed and hence the sensor is stirring insensitive, but the signal will stabilize more quickly if the sensor is stirred after putting it into the sample.
Optical sensors are growing in popularity due to the low-cost, low power requirements and long term stability. They provide viable alternatives to electrode-based sensors or more complicated analytical instrumentation.
Major international conferences are devoted to their development e.g Europtrode VIII Tubeingen 2006, OFS 18, Cancun 2006.