Jump to content

Membrane bioreactor: Difference between revisions

From Wikipedia, the free encyclopedia
Content deleted Content added
Line 51: Line 51:
=== Biological performances/kinetics ===
=== Biological performances/kinetics ===
==== COD Removal and Sludge Yield ====
==== COD Removal and Sludge Yield ====
Simply due to the high number of microorganism in MBRs, the pollutants uptake rate can be increased. This leads to better degradation in a given time span or to smaller required reactor volumes. In comparison to the conventional [[activated sludge]] process which typically achieves 95%, COD removal can be increased to 96-99% in MBRs (see table, <ref> M. Kraume, U. Bracklow, A. Vocks, A. Drews, Nutrients Removal in MBRs for Municipal Wastewater Treatment. Wat. Sci. Tech. 51 (2005), 391-402</ref>). COD and BOD5 removal are found to increase with MLSS concentration. Above 15g/L COD removal becomes almost independent of biomass concentration at >96% <ref>A. Drews, H. Evenblij, S. Rosenberger, Potential and drawbacks of microbiology-membrane interaction in membrane bioreactors, Environmental Progress 24 (4) (2005) 426-433</ref>. Arbitrary high MLSS concentrations are not employed, however, as oxygen transfer is impeded due to higher and [[Non-Newtonian fluid]] viscosity. Kinetics may also differ due to easier substrate access. In ASP, flocs may reach several 100 μm in size. This means that the substrate can reach the active sites only by diffusion which causes an additional resistance and limits the overall reaction rate (diffusion controlled). Hydrodynamic stress in MBRs reduces floc size (to 3.5 μm in sidestream MBRs) and thereby increases the apparent reaction rate. Like in the conventional ASP, sludge yield is decreased at higher SRT or biomass concentration. Little or no sludge is produced at sludge loading rates of 0.01 kgCOD/(kgMLSS d) <ref> T. Stephenson, S. Judd, B. Jefferson, K. Brindle, Membrane bioreactors for wastewater treatment, IWA Publishing (2000)</ref>. Due to the biomass concentration limit imposed, such low loading rates would result in enormous tank sizes or long HRTs in conventional ASP.
Simply due to the high number of microorganism in MBRs, the pollutants uptake rate can be increased. This leads to better degradation in a given time span or to smaller required reactor volumes. In comparison to the conventional [[activated sludge]] process which typically achieves 95%, COD removal can be increased to 96-99% in MBRs (see table, <ref> M. Kraume, U. Bracklow, M. Vocks, A. Drews, Nutrients Removal in MBRs for Municipal Wastewater Treatment. Wat. Sci. Tech. 51 (2005), 391-402</ref>). COD and BOD5 removal are found to increase with MLSS concentration. Above 15g/L COD removal becomes almost independent of biomass concentration at >96% <ref>A. Drews, H. Evenblij, S. Rosenberger, Potential and drawbacks of microbiology-membrane interaction in membrane bioreactors, Environmental Progress 24 (4) (2005) 426-433</ref>. Arbitrary high MLSS concentrations are not employed, however, as oxygen transfer is impeded due to higher and [[Non-Newtonian fluid]] viscosity. Kinetics may also differ due to easier substrate access. In ASP, flocs may reach several 100 μm in size. This means that the substrate can reach the active sites only by diffusion which causes an additional resistance and limits the overall reaction rate (diffusion controlled). Hydrodynamic stress in MBRs reduces floc size (to 3.5 μm in sidestream MBRs) and thereby increases the apparent reaction rate. Like in the conventional ASP, sludge yield is decreased at higher SRT or biomass concentration. Little or no sludge is produced at sludge loading rates of 0.01 kgCOD/(kgMLSS d) <ref> T. Stephenson, S. Judd, B. Jefferson, K. Brindle, Membrane bioreactors for wastewater treatment, IWA Publishing (2000)</ref>. Due to the biomass concentration limit imposed, such low loading rates would result in enormous tank sizes or long HRTs in conventional ASP.


==== Nutrient Removal ====
==== Nutrient Removal ====

Revision as of 17:06, 8 April 2008

(Note: this page describes the application of membrane bioreactor for the treatment of wastewaters)

The membrane bioreactor (MBR) is the combination of a membrane process like microfiltration or ultrafiltration with a suspended growth bioreactor, and is now widely used for municipal and industrial wastewater treatment with plant sizes up to 80,000 population equivalent (i.e. 48 MLD) [1].

Simple schematic describing the MBR process

When used with domestic wastewater, MBR processes could produce effluent of high quality enough to be discharged to coastal, surface or brackish waterways or to be reclaimed for urban irrigation. Other advantages of MBRs over conventional processes include small footprint, easy retrofit and upgrade of old wastewater treatment plants. Two MBR configurations exist: internal, where the membranes are immersed in and integral to the biological reactor; and external/sidestream, where membranes are a separate unit process requiring an intermediate pumping step.

chematic of conventional activated sludge process (top) and membrane bioreactor (bottom)

Recent technical innovation and significant membrane cost reduction have pushed MBRs to become an established process option to treat wastewaters [2]. As a result, the MBR process has now become an attractive option for the treatment and reuse of industrial and municipal wastewaters, as evidenced by their constantly rising numbers and capacity. The current MBR market has been estimated to value around US$216 million in 2006 and to rise to US$363 million by 2010 [3].

Schematic of a submerged MBR

MBR history and basic operating parameters

The MBR process was introduced by the late 1960s, as soon as commercial scale ultrafiltration (UF) and microfiltration (MF) membranes were available. The original process was introduced by Dorr-Olivier Inc. and combined the use of an activated sludge bioreactor with a crossflow membrane filtration loop. The flat sheet membranes used in this process were polymeric and featured pore sizes ranging from 0.003 to 0.01 μm. Although the idea of replacing the settling tank of the conventional activated sludge process was attractive, it was difficult to justify the use of such a process because of the high cost of membranes, low economic value of the product (tertiary effluent) and the potential rapid loss of performance due to membrane fouling. As a result, the focus was on the attainment of high fluxes, and it was therefore necessary to pump the mixed liquor suspended solids (MLSS) at high crossflow velocity at significant energy penalty (of the order 10 kWh/m3 product) to reduce fouling. Due to the poor economics of the first generation MBRs, they only found applications in niche areas with special needs like isolated trailer parks or ski resorts for example.

The breakthrough for the MBR came in 1989 with the idea of Yamamoto and co-workers to submerge the membranes in the bioreactor. Until then, MBRs were designed with the separation device located external to the reactor (sidestream MBR) and relied on high transmembrane pressure (TMP) to maintain filtration. With the membrane directly immersed into the bioreactor, submerged MBR systems are usually preferred to sidestream configuration, especially for domestic wastewater treatment. The submerged configuration relies on coarse bubble aeration to produce mixing and limit fouling. The energy demand of the submerged system can be up to 2 orders of magnitude lower than that of the sidestream systems and submerged systems operate at a lower flux, demanding more membrane area. In submerged configurations, aeration is considered as one of the major parameter on process performances both hydraulic and biological. Aeration maintains solids in suspension, scours the membrane surface and provides oxygen to the biomass, leading to a better biodegradability and cell synthesis.

The other key steps in the recent MBR development were the acceptance of modest fluxes (25% or less of those in the first generation), and the idea to use two-phase bubbly flow to control fouling. The lower operating cost obtained with the submerged configuration along with the steady decrease in the membrane cost encouraged an exponential increase in MBR plant installations from the mid 90s. Since then, further improvements in the MBR design and operation have been introduced and incorporated into larger plants. While early MBRs were operated at solid retention times (SRT) as high as 100 days with mixed liquor suspended solids up to 30 g/L, the recent trend is to apply lower solid retention times (around 10-20 days), resulting in more manageable mixed liquor suspended solids (MLSS) levels (10-15 g/L). Thanks to these new operating conditions, the oxygen transfer and the pumping cost in the MBR have tended to decrease and overall maintenance has been simplified. There is now a range of MBR systems commercially available, most of which use submerged membranes although some external modules are available; these external systems also use two-phase flow for fouling control. Typical hydraulic retention times (HRT) range between 3 and 10 hours. In terms of membrane configurations, mainly hollow fibre and flat sheet membranes are applied for MBR applications [4].

Major considerations in MBR

Fouling and fouling control

The MBR filtration performance inevitably decreases with filtration time. This is due to the deposition of soluble and particulate materials onto and into the membrane, attributed to the interactions between activated sludge components and the membrane. This major drawback and process limitation has been under investigation since the early MBRs, and remains one of the most challenging issues facing further MBR development [5], [6].

Illustration of membrane fouling

In recent reviews covering membrane applications to bioreactors, it has been shown that, as with other membrane separation processes, membrane fouling is the most serious problem affecting system performance. Fouling leads to a significant increase in hydraulic resistance, manifested as permeate flux decline or transmembrane pressure (TMP) increase when the process is operated under constant-TMP or constant-flux conditions respectively. Frequent membrane cleaning and replacement is therefore required, increasing significantly the operating costs.

Membrane fouling results from interaction between the membrane material and the components of the activated sludge liquor, which include biological flocs formed by a large range of living or dead microorganisms along with soluble and colloidal compounds. The suspended biomass has no fixed composition and varies both with feed water composition and MBR operating conditions employed. Thus though many investigations of membrane fouling have been published, the diverse range of operating conditions and feedwater matrices employed, the different analytical methods used and the limited information reported in most studies on the suspended biomass composition, has made it difficult to establish any generic behaviour pertaining to membrane fouling in MBRs specifically.

Factors influencing fouling (interactions in red)

The air-induced cross flow obtained in submerged MBR can efficiently remove or at least reduce the fouling layer on the membrane surface. A recent review reports the latest findings on applications of aeration in submerged membrane configuration and describes the enhancement of performances offered by gas bubbling [7]. As an optimal air flow-rate has been identified behind which further increases in aeration have no effect on fouling removal, the choice of aeration rate is a key parameter in MBR design.

Many other anti-fouling strategies can be applied to MBR applications. They comprise, for example:

  • Intermittent permeation, where the filtration is stopped at regular time interval for a couple of minutes before being resumed. Particles deposited on the membrane surface tend to diffuse back to the reactor; this phenomena being increased by the continuous aeration applied during this resting period.
  • Membrane backwashing, where permeate water is pumped back to the membrane, and flow through the pores to the feed channel, dislodging internal and external foulants.
  • Air backwashing, where pressurized air in the permeate side of the membrane build up and release a significant pressure within a very short period of time. Membrane modules therefore need to be in a pressurised vessel coupled to a vent system. Air usually does not go through the membrane. If it was, the air would dry the membrane and a rewet step would be necessary, by pressurizing the feed side of the membrane.

In addition, different types/intensities of chemical cleaning may also be recommended:

  • Chemically enhanced backwash (daily);
  • Maintenance cleaning with higher chemical concentration (weekly);
  • Intensive chemical cleaning (once or twice a year).

Intensive cleaning is also carried out when further filtration cannot be sustained because of an elevated transmembrane pressure (TMP). Each of the four main MBR suppliers (Kubota, Memcor, Mitsubishi and Zenon) have their own chemical cleaning recipes, which differ mainly in terms of concentration and methods (see Table 1). Under normal conditions, the prevalent cleaning agents remain NaOCl (Sodium Hypochlorite) and citric acid. It is common for MBR suppliers to adapt specific protocols for chemical cleanings (i.e. chemical concentrations and cleaning frequencies) for individual facilities [8].

Intensive chemical cleaning protocols for four MBR suppliers (the exact protocol for chemical cleaning can vary from a plant to another)

Biological performances/kinetics

COD Removal and Sludge Yield

Simply due to the high number of microorganism in MBRs, the pollutants uptake rate can be increased. This leads to better degradation in a given time span or to smaller required reactor volumes. In comparison to the conventional activated sludge process which typically achieves 95%, COD removal can be increased to 96-99% in MBRs (see table, [9]). COD and BOD5 removal are found to increase with MLSS concentration. Above 15g/L COD removal becomes almost independent of biomass concentration at >96% [10]. Arbitrary high MLSS concentrations are not employed, however, as oxygen transfer is impeded due to higher and Non-Newtonian fluid viscosity. Kinetics may also differ due to easier substrate access. In ASP, flocs may reach several 100 μm in size. This means that the substrate can reach the active sites only by diffusion which causes an additional resistance and limits the overall reaction rate (diffusion controlled). Hydrodynamic stress in MBRs reduces floc size (to 3.5 μm in sidestream MBRs) and thereby increases the apparent reaction rate. Like in the conventional ASP, sludge yield is decreased at higher SRT or biomass concentration. Little or no sludge is produced at sludge loading rates of 0.01 kgCOD/(kgMLSS d) [11]. Due to the biomass concentration limit imposed, such low loading rates would result in enormous tank sizes or long HRTs in conventional ASP.

Nutrient Removal

Nutrient removal is one of the main concerns in modern wastewater treatment especially in areas that are sensitive to eutrophication. Like in the conventional ASP, currently, the most widely applied technology for N-removal from municipal wastewater is nitrification combined with denitrification. Besides phosphorus precipitation, enhanced biological phosphorus removal (EBPR) can be implemented which requires an additional anaerobic process step. Some characteristics of MBR technology render EBPR in combination with post-denitrification an attractive alternative that achieves very low nutrient effluent concentrations [12].

Nutrients Removal in MBRs for Municipal Wastewater Treatment[13]

Anaerobic MBRs

Anaerobic MBRs were introduced in the 1980s in South Africa and currently see a renaissance in research. However, anaerobic processes are normally used when a low cost treatment is required that enables energy recovery but does not achieve advanced treatment (low carbon removal, no nutrients removal). In contrast, membrane-based technologies enable advanced treatment (disinfection), but at high energy cost. Therefore, the combination of both can only be economically viable if a compact process for energy recovery is desired, or when disinfection is required after anaerobic treatment (cases of water reuse with nutrients). If maximal energy recovery is desired, a single anaerobic process will be always superior to a combination with a membrane process.

Mixing/Hydrodynamics

Like in any other reactors, the hydrodynamics (or mixing) within an MBR plays an important role in determining the pollutant removal and fouling control within an MBR. It has a substantial effect on the energy usage and size requirements of an MBR, therefore the whole life cost of an MBR.

The removal of pollutants is greatly influenced by the length of time fluid elements spend in the MBR (i.e. the residence time distribution or RTD). The residence time distribution is a description of the hydrodynamics/mixing in the system and is determined by the design of the MBR (e.g. MBR size, inlet/recycle flowrates, wall/baffle/mixer/aerator positioning, mixing energy input). An example of the effect of mixing is that a continuous stirred-tank reactor will not have as high pollutant conversion per unit volume of reactor as a plug flow reactor.

The control of fouling, as previously mentioned, is primarily undertaken using coarse bubble aeration. The distribution of bubbles around the membranes, the shear at the membrane surface for cake removal and the size of the bubble are greatly influenced by the mixing/hydrodynamics of the system. The mixing within the system can also influence the production of possible foulants. For example, vessels not completely mixed (i.e. plug flow reactors) are more susceptible to the effects of shock loads which may cause cell lysis and release of soluble microbial products.

Example of computational fluid dynamic (CFD) modelling results (streamlines) for a full scale MBR (Adapted from the Project AMEDEUS – Australian Node Newsletter August 2007[14]).

Many factors affect the hydrodynamics of wastewater processes and hence MBRs. These range from physical properties (e.g. mixture rheology and gas/liquid/solid density etc) to the fluid boundary conditions (e.g. inlet/outlet/recycle flowrates, baffle/mixer position etc). However, many factors are peculiar to MBRs, these cover the filtration tank design (e.g membrane type, multiple outlets attributed to membranes, membrane packing density, membrane orientation etc) and it’s operation (e.g. membrane relaxation, membrane back flush etc).

The mixing modelling and design techniques applied to MBRs are very similar to those used for conventional activated sludge systems. They include the relatively quick and easy compartmental modelling technique which will only derive the RTD of a process (e.g. the MBR) or the process unit (e.g. membrane filtration vessel) and relies on broad assumptions of the mixing properties of each sub unit. Computational fluid dynamics modelling (CFD) on the other hand does not rely on broad assumptions of the mixing characteristics and attempts to predict the hydrodynamics from a fundamental level. It is applicable to all scales of fluid flow and can reveal much information about the mixing in a process, ranging from the RTD to the shear profile on a membrane surface. Visualisation of MBR CFD modelling results is shown below.

Investigations of MBR hydrodynamics have occurred at many different scales, ranging from examination of shear stress at the membrane surface to RTD analysis of the whole MBR. Cui et al (2003) [15]investigated the movement of Taylor bubbles through tubular membranes, Prieske et al (2007) [16] examined the entire membrane filtration vessel using CFD and velocity measurements, while Brannock et al (2007) [17] examined the entire MBR using tracer study experiments and RTD analysis.

MBR Suppliers

The design of the reactor (including membrane, baffle and aerator locations) and the mode of operation of the membrane also appear as key parameters in the optimisation of the system. Several immersed MBR designs are currently proposed by the leading membrane suppliers such as GE-Zenon (Canada), X-Flow (The Netherlands), Siemens-Australia (Australia), Mitsubishi and Kubota (Japan). In each case, the process proposed is very specific. Not only the membrane material and configuration used are different, but the operating conditions, cleaning protocols and reactor designs also change from a company to another. For example, the flat sheet membrane provided by Kubota does not allow backwash operation, while hollow fibre membrane type from Zenon and Memcor (USFilter) have been especially designed to hydraulically backwash the membrane on a given frequency (around every 10 min).

Membrane and plant supplier links:

Current Main Research Groups

References

  1. ^ S. Judd, The MBR book (2006) Principles and applications of membrane bioreactors in water and wastewater treatment, Elsevier, Oxford
  2. ^ S. Judd, The MBR book (2006) Principles and applications of membrane bioreactors in water and wastewater treatment, Elsevier, Oxford
  3. ^ S. Atkinson, research studies predict strong growth for MBR markets. Membrane Technology (2006) 8-10
  4. ^ P. Le-Clech, V. Chen, A.G. Fane, Fouling in membrane bioreactors used for wastewater treatment – A review. J. Memb. Sci. 284 (2006) 17-53
  5. ^ http://www.membrane.unsw.edu.au/research/mbr.htm
  6. ^ Z.F. Cui, S. Chang, A.G. Fane, The use of gas bubbling to enhance membrane process, J. Memb. Sci. 2211 (2003) 1-35
  7. ^ Z.F. Cui, S. Chang, A.G. Fane, The use of gas bubbling to enhance membrane process, J. Memb. Sci. 2211 (2003) 1-35
  8. ^ P. Le-Clech, V. Chen, A.G. Fane, Fouling in membrane bioreactors used for wastewater treatment – A review. J. Memb. Sci. 284 (2006) 17-53
  9. ^ M. Kraume, U. Bracklow, M. Vocks, A. Drews, Nutrients Removal in MBRs for Municipal Wastewater Treatment. Wat. Sci. Tech. 51 (2005), 391-402
  10. ^ A. Drews, H. Evenblij, S. Rosenberger, Potential and drawbacks of microbiology-membrane interaction in membrane bioreactors, Environmental Progress 24 (4) (2005) 426-433
  11. ^ T. Stephenson, S. Judd, B. Jefferson, K. Brindle, Membrane bioreactors for wastewater treatment, IWA Publishing (2000)
  12. ^ A. Drews, H. Evenblij, S. Rosenberger, Potential and drawbacks of microbiology-membrane interaction in membrane bioreactors, Environmental Progress 24 (4) (2005) 426-433
  13. ^ M. Kraume, U. Bracklow, M. Vocks, A. Drews, Nutrients Removal in MBRs for Municipal Wastewater Treatment. Wat. Sci. Tech. 51 (2005), 391-402
  14. ^ http://www.mbr-network.eu/mbr-forum/forum_entry.php?id=194
  15. ^ Z.F. Cui, S. Chang, A.G. Fane, The use of gas bubbling to enhance membrane process, J. Memb. Sci. 2211 (2003) 1-35
  16. ^ Prieske, H., Drews, A. and Kraume, M. (2007) Prediction of the circulation velocity in a membrane bioreactor, IWA Harrogate, UK
  17. ^ Brannock, M.W.D., Kuechle, B., Wang, Y. and Leslie, G. (2007) Evaluation of membrane bioreactor performance via residence time distribution analysis: effects of membrane configuration in full-scale MBRs, IWA Berlin, Germany