Electric motor: Difference between revisions
Stepper added to Major categories tabulation's Magnet-AC electronics cell with citations to Haymeyer & King (Andy) |
|||
Line 451: | Line 451: | ||
===Synchronous motor=== |
===Synchronous motor=== |
||
{{Main|Synchronous motor}} |
{{Main|Synchronous motor}} |
||
==== Brushless DC motor ==== |
==== Brushless DC''''''''''''''' motor ==== |
||
{{Main|Brushless DC electric motor}} |
{{Main|Brushless DC electric motor}} |
||
Some of the problems of the brushed DC motor are eliminated in the brushless design. In this motor, the mechanical "rotating switch" or commutator/brushgear assembly is replaced by an external electronic switch synchronised to the rotor's position. Brushless motors are typically 85–90% efficient or more. Efficiency for a brushless electric motor of up to 96.5% have been reported,<ref name="Nozawa (2009)">{{cite web|last=Nozawa| first=Tetsuo (2009)|title=Tokai University Unveils 100W DC Motor with 96% Efficiency|url=http://techon.nikkeibp.co.jp/english/NEWS_EN/20090403/168295/|publisher=Tech-On -- Nikkei Electronics}}</ref> whereas DC motors with brushgear are typically 75–80% efficient. |
Some of the problems of the brushed DC motor are eliminated in the brushless design. In this motor, the mechanical "rotating switch" or commutator/brushgear assembly is replaced by an external electronic switch synchronised to the rotor's position. Brushless motors are typically 85–90% efficient or more. Efficiency for a brushless electric motor of up to 96.5% have been reported,<ref name="Nozawa (2009)">{{cite web|last=Nozawa| first=Tetsuo (2009)|title=Tokai University Unveils 100W DC Motor with 96% Efficiency|url=http://techon.nikkeibp.co.jp/english/NEWS_EN/20090403/168295/|publisher=Tech-On -- Nikkei Electronics}}</ref> whereas DC motors with brushgear are typically 75–80% efficient. |
Revision as of 08:00, 20 February 2013
An electric motor is an electromechanical device that converts electrical energy into mechanical energy.
The interaction between an electric motor's magnetic field and winding currents generates force and useful in the motor. The reverse process, producing electrical energy from mechanical energy, is done by generators such as an alternator or a dynamo; some electric motors can also be used as generators, for example, a traction motor on a vehicle may perform both tasks. Electric machines are traditionally understood to include transformers as well as electric motors and generators.
Found in applications as diverse as industrial fans, blowers and pumps, machine tools, household appliances, power tools, and disk drives, electric motors can be powered by direct current sources, such as from batteries, motor vehicles or rectifiers, or by alternating current sources, such as from the power grid, inverters or generators. Small motors may be found in electric wristwatches. General-purpose motors with highly standardized dimensions and characteristics provide convenient mechanical power for industrial use. The largest of electric motors are used for propulsion of ships, pipeline compressors, and water pumps with ratings approaching a million watts. Electric motors may be classified by electric power source type, internal construction, application, type of motion output, and so on.
The principle behind production of mechanical force by the interactions of an electric current and a magnetic field, Ampère's force law, was discovered by André-Marie Ampère in 1820. Although electric motors were gradually improved from 1821 through the end of the 19th century, commercial exploitation of electric motors on a large scale required efficient electrical generators and electrical distribution networks. The first commercially successful motors, DC motors, were made around 1873 by Zénobe Gramme.[1]
Devices such as magnetic solenoids and loudspeakers that convert electricity into motion but do not generate usable mechanical power are respectively referred to as actuators and transducers. Electric motors are used to produce rotary or linear torque or force.[2]
History
Background
The conversion of electrical energy into mechanical energy by electromagnetic means was demonstrated by the British scientist Michael Faraday in 1821. A free-hanging wire was dipped into a pool of mercury, on which a permanent magnet was placed. When a current was passed through the wire, the wire rotated around the magnet, showing that the current gave rise to a close circular magnetic field around the wire.[4] This motor is often demonstrated in school physics classes, but brine (salt water) is sometimes used in place of the toxic mercury. A later refinement is the Barlow's wheel. Early homopolar-like devices were to remain unsuited to practical application until late in the nineteenth century.
In 1827, Hungarian physicist Ányos Jedlik started experimenting with electromagnetic coils. After Jedlik solved the technical problems of the continuous rotation with the invention of commutator, he called his early devices as "electromagnetic self-rotors". Although they were used only for instructional purposes, in 1828 Jedlik demonstrated the first device to contain the three main components of practical direct current motors: the stator, rotor and commutator. The device employed no permanent magnets, as the magnetic fields of both the stationary and revolving components were produced solely by the currents flowing through their windings.[6] [7] [8] [9][10] [11] [12]
The multipolar motors can use the power of both magnetic interaction: the attraction and repulsion.
The first electric motors
The first commutator-type direct current electric motor capable of turning machinery was invented by the British scientist William Sturgeon in 1832.[13] Following Sturgeon's work, a commutator-type direct-current electric motor made with the intention of commercial use was built by Americans Emily and Thomas Davenport and patented in 1837. Their motors ran at up to 600 revolutions per minute, and powered machine tools and a printing press.[14] Due to the high cost of the zinc electrodes required by primary battery power, the motors were commercially unsuccessful and the Davenports went bankrupt. Several inventors followed Sturgeon in the development of DC motors but all encountered the same cost issues with primary battery power. No electricity distribution had been developed at the time. Like Sturgeon's motor, there was no practical commercial market for these motors.[15]
In 1855 Jedlik built a device using similar principles to those used in his electromagnetic self-rotors that was capable of useful work.[6][12] He built a model electric motor-propelled vehicle that same year.[16]
The modern DC motor was invented by accident in 1873, when Zénobe Gramme connected the dynamo he had invented to a second similar unit, driving it as a motor. The Gramme machine was the first electric motor that was successful in the industry.[1]
In 1886 Frank Julian Sprague invented the first practical DC motor, a non-sparking motor that maintained relatively constant speed under variable loads. Other Sprague electric inventions about this time greatly improved grid electric distribution (prior work done while employed by Thomas Edison), allowed power from electric motors to be returned to the electric grid, provided for electric distribution to trolleys via overhead wires and the trolley pole, and provided controls systems for electric operations. This allowed Sprague to use electric motors to invent the first electric trolley system in 1887–88 in Richmond VA, the electric elevator and control system in 1892, and the electric subway with independently powered centrally controlled cars, which were first installed in 1892 in Chicago by the South Side Elevated Railway where it became popularly known as the "L". Sprague's motor and related inventions led to an explosion of interest and use in electric motors for industry, while almost simultaneously another great inventor was developing its primary competitor, which would become much more widespread. The development of electric motors of acceptable efficiency was delayed for several decades by failure to recognize the extreme importance of a relatively small air gap between rotor and stator. Efficient designs have a comparatively small air gap.[17] The St. Louis motor, long used in classrooms to illustrate motor principles, is extremely inefficient for the same reason, as well as appearing nothing like a modern motor.[18]
Application of electric motors revolutionized industry. Industrial processes were no longer limited by power transmission using line shafts, belts, compressed air or hydraulic pressure. Instead every machine could be equipped with its own electric motor, providing easy control at the point of use, and improving power transmission efficiency. Electric motors applied in agriculture eliminated human and animal muscle power from such tasks as handling grain or pumping water. Household uses of electric motors reduced heavy labor in the home and made higher standards of convenience, comfort and safety possible. Today, electric motors stand for more than half of the electric energy consumption in the US.[19]
AC motor development
In 1824, the French physicist François Arago formulated the existence of rotating magnetic fields, termed Arago's rotations, which, by manually turning switches on and off, Walter Baily demonstrated in 1879 as in effect the first primitive induction motor.[20][21] [22][23] In the 1880s, many inventors were trying to develop workable AC motors[24] because AC's advantages in long distance high voltage transmission were counterbalanced by the inability to operate motors on AC. Practical rotating AC induction motors were independently invented by Galileo Ferraris and Nikola Tesla, a working motor model having been demonstrated by the former in 1885 and by the latter in 1887. In 1888, the Royal Academy of Science of Turin published Ferraris's research detailing the foundations of motor operation while however concluding that "the apparatus based on that principle could not be of any commercial importance as motor."[25][26][23][27][28][29][30][31][32][33] [34] [35] [36] In 1888, Tesla presented his paper A New System for Alternating Current Motors and Transformers to the AIEE that described three patented two-phase four-stator-pole motor types: one with a four-pole rotor forming a non-self-starting reluctance motor, another with a wound rotor forming a self-starting induction motor, and the third a true synchronous motor with separately-excited DC supply to rotor winding. One of the patents Tesla filed in 1887, however, also described a shorted-winding-rotor induction motor. George Westinghouse promptly bought Tesla’s patents, employed Tesla to develop them, and assigned C. F. Scott to help Tesla, Tesla leaving for other pursuits in 1889.[37][38] [39] [30] [23] [37] [40] [41][42] [43][33][44] [35][36][38][45] The constant speed AC induction motor was found not to be suitable for street cars [24] but Westinghouse engineers successfully adapted it to power a mining operation in Telluride, Colorado in 1891.[46][47][48] Steadfast in his promotion of three-phase development, Mikhail Dolivo-Dobrovolsky invented the three-phase cage-rotor induction motor in 1889 and the three-limb transformer in 1890. This type of motor is now used for the vast majority of commercial applications.[49][50] However, he claimed that Tesla's motor was not practical because of two-phase pulsations, which prompted him to persist in his three-phase work.[51] Although Westinghouse achieved its first practical induction motor in 1892 and developed a line of polyphase 60 hertz induction motors in 1893, these early Westinghouse motors were two-phase motors with wound rotors until B. G. Lamme developed a rotating bar winding rotor.[37] The General Electric Company began developing three-phase induction motors in 1891.[37] By 1896, General Electric and Westinghouse signed a cross-licensing agreement for the bar-winding-rotor design, later called the squirrel-cage rotor.[37] Induction motor improvements flowing from these inventions and innovations were such that a 100 horsepower induction motor currently has the same mounting dimensions as a 7.5 horsepower motor in 1897.[37]
Historical summary
The following tabulation summarizes electric motor development during the 19th century.
19th Century Development
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Characterization
Terminology
In an electric motor the moving part is called the rotor and the stationary part is called the stator. Magnetic fields are produced on poles, and these can be salient poles where they are driven by windings of electrical wire. A shaded-pole motor has a winding around part of the pole that delays the phase of the magnetic field for that pole.
A commutator switches the current flow to the rotor windings depending on the rotor angle.
A DC motor is powered by direct current, although there is almost always an internal mechanism (such as a commutator) converting DC to AC for part of the motor. An AC motor is supplied with alternating current, often avoiding the need for a commutator. A synchronous motor is an AC motor that runs at a speed fixed fraction of power supply frequency whereas an asynchronous motor or induction motor runs at slip speed, which is somewhat less than equivalent synchronous speed and varies somewhat with torque changes. Universal motors can run on either AC or DC, though the maximum frequency of the AC supply may be limited.
Major categories
At least 3 different operating principles are used to make electric motors: magnetic, electrostatic and piezoelectric. By far the most common is magnetic.
Nearly all electric motors are based around magnetism (exceptions include piezoelectric motors and ultrasonic motors). In these motors, magnetic fields are formed in both the rotor and the stator. The product between these two fields gives rise to a force, and thus a torque on the motor shaft. One, or both, of these fields must be made to change with the rotation of the motor. This is done by switching the poles on and off at the right time, or varying the strength of the pole.
The main types are DC motors and AC motors, the former increasingly being displaced by the latter.
Considering all rotating (or linear) electric motors require synchronism between a moving magnetic field and a moving current sheet for average torque production, there is a clear distinction between an asynchronous motor and synchronous types. An asynchronous or induction motor requires slip - relative movement between the magnetic field (generated by the stator) and a winding set (the rotor) to induce current in the rotor by mutual inductance. T
In the synchronous types, induction (or slip) is not a requisite for magnetic field or current production (e.g. permanent magnet motors, synchronous brushless wound-rotor doubly fed electric machine).
Rated output power is also used to categorize motors. Those of less than 746 watts, for example, are often referred to as fractional horsepower motors (FHP) in reference to the old imperial measurement.
Commutation | ||||||
---|---|---|---|---|---|---|
No commutation | Electronic | Electromechanical | Electromechanical | |||
Drive Output | ||||||
AC | AC7 | DC | DC or AC1 | |||
Rotor | Iron | No winding Ferromagnetic core2 |
Reluctance: • Hysteresis • SyRM |
SRM6 Stepper Coilgun Mass driver |
SRM5 | |
Magnet | No winding PM core |
BLDC6, 7 PMSM3, 6 Stepper[64][65] |
PM DC6 | |||
Induction winding, usually with core |
Cage or wound winding9 Ferromagnetic core2 |
SCIM4 or WRIM5 | SCIM6 or WRIM8 | |||
DC winding usually with core |
DC winding Ferromagnetic core2 |
Brushed DC: * Series • Shunt • Compound |
Universal1 | |||
Synchronous winding |
Separatedly-excited DC field winding Ferromagnetic core2 |
WFSM3 | WFSM6 |
Notes:
- Rotation is independent of the frequency of the AC voltage.
- Core with no magnetization.
- Rotation is equal to synchronous speed (motor stator field speed).
- Rotation is equal to slip speed (synchronous speed less slip).
- Usually used for motor starting but can be used to vary load speed.
- Variable-speed operation.
- AC can typically be either six-step or sinusoidal waveforms except for BLDC which is trapezoidal waveform.
- Used in slip energy recovery and double-fed induction machine applications.
- Cage winding refers to shorted-circuited squirrel-cage rotor, wound winding being connected externally through commutating brushes.
Abbreviations:
- BLDC - Brushless DC motor
- PM - Permanent magnet
- PMSM - Permanent magnet synchronous motor
- SCIM - Squirrel-cage induction motor
- SRM - Switched reluctance motor
- SyRM - Synchronous reluctance motor
- WRIM - Wound-rotor induction motor
- WRSM - Wound-rotor synchronous motor
Performance parameters and standards
Specifying an electric motor
When specifying what type of electric motor is needed, the mechanical power available at the shaft is used. This means that users can predict the torque and speed of the motor without having to know the mechanical losses associated with the motor. Example: 10 kW induction motor.
Power
The power output of a rotary electric motor is:
Where P is in horsepower, rpm is the shaft speed in revolutions per minute and T is the torque in foot pounds. The equivalent equation with SI-units is:
Where P is the power in watts, rpm is the shaft speed in revolutions per minute and T is the torque in Nm.[66]
And for a linear motor:
Where P is the power in watts, and F is in Newtons and v is the speed in metres per second.
Efficiency
To calculate a motor's efficiency, the mechanical output power is divided by the electrical input power: , where is energy conversion efficiency, is electrical input power, and is mechanical output power.
In simplest case , and , where is input voltage, is input current, is output torque, and is output angular velocity. It is possible to derive analytically the point of maximum efficiency. It is typically at less than 1/2 the stall torque.
Torque capability of motor types
When optimally designed within a given core saturation constraint and for a given active current (i.e., torque current), voltage, pole-pair number, excitation frequency (i.e., synchronous speed), and air-gap flux density, all categories of electric motors or generators will exhibit virtually the same maximum continuous shaft torque (i.e., operating torque) within a given air-gap area with winding slots and back-iron depth, which determines the physical size of electromagnetic core. Some applications require bursts of torque beyond the maximum operating torque, such as short bursts of torque to accelerate an electric vehicle from standstill. Always limited by magnetic core saturation or safe operating temperature rise and voltage, the capacity for torque bursts beyond the maximum operating torque differs significantly between categories of electric motors or generators.
Capacity for bursts of torque should not be confused with field weakening capability. Field weakening allows an electric machine to operate beyond the designed frequency of excitation.
Electric machines without a transformer circuit topology, such as Field-Wound (i.e., electromagnet) or Permanent Magnet (PM) Synchronous electric machines cannot realize bursts of torque higher than the maximum designed torque without saturating the magnetic core and rendering any increase in current as useless. Furthermore, the permanent magnet assembly of PM synchronous electric machines can be irreparably damaged, if bursts of torque exceeding the maximum operating torque rating are attempted.
Electric machines with a transformer circuit topology, such as Induction (i.e., asynchronous) electric machines, Induction Doubly Fed electric machines, and Induction or Synchronous Wound-Rotor Doubly Fed (WRDF) electric machines, exhibit very high bursts of torque because the active current (i.e., Magneto-Motive-Force or the product of current and winding-turns) induced on either side of the transformer oppose each other and as a result, the active current contributes nothing to the transformer coupled magnetic core flux density, which would otherwise lead to core saturation.
Electric machines that rely on Induction or Asynchronous principles short-circuit one port of the transformer circuit and as a result, the reactive impedance of the transformer circuit becomes dominant as slip increases, which limits the magnitude of active (i.e., real) current. Still, bursts of torque that are two to three times higher than the maximum design torque are realizable.
The Synchronous WRDF electric machine is the only electric machine with a truly dual ported transformer circuit topology (i.e., both ports independently excited with no short-circuited port). The dual ported transformer circuit topology is known to be unstable and requires a multiphase slip-ring-brush assembly to propagate limited power to the rotor winding set. If a precision means were available to instantaneously control torque angle and slip for synchronous operation during motoring or generating while simultaneously providing brushless power to the rotor winding set (see Brushless wound-rotor doubly fed electric machine), the active current of the Synchronous WRDF electric machine would be independent of the reactive impedance of the transformer circuit and bursts of torque significantly higher than the maximum operating torque and far beyond the practical capability of any other type of electric machine would be realizable. Torque bursts greater than eight times operating torque have been calculated.
Continuous torque density
The continuous torque density of conventional electric machines is determined by the size of the air-gap area and the back-iron depth, which are determined by the power rating of the armature winding set, the speed of the machine, and the achievable air-gap flux density before core saturation. Despite the high coercivity of neodymium or samarium-cobalt permanent magnets, continuous torque density is virtually the same amongst electric machines with optimally designed armature winding sets. Continuous torque density should never be confused with peak torque density, which comes with the manufacturer's chosen method of cooling, which is available to all, or period of operation before destruction by overheating of windings or even permanent magnet damage.
Continuous power density
The continuous power density is determined by the product of the continuous torque density and the constant torque speed range of the electric machine.
Standards
The following are major design and manufacturing standards covering electric motors:
- International Electrotechnical Commission: IEC 60034 Rotating Electrical Machines
- National Electrical Manufacturers Association: MG-1 Motors and Generators
- Underwriters Laboratories: UL 1004 - Standard for Electric Motors
DC motor
A DC motor is designed to run on DC electric power. Two examples of pure DC designs are Michael Faraday's homopolar motor (which is uncommon), and the ball bearing motor, which is (so far) a novelty. By far the most common DC motor types are the brushed and brushless types, which use internal and external commutation respectively to reverse the current in the windings in synchronism with rotation.
Commutated DC motor
A commutated DC motor has a set of rotating windings wound on an armature mounted on a rotating shaft. The shaft also carries the commutator a long-lasting rotary electrical switch that periodically reverses the flow of current in the rotor windings as the shaft rotates. Thus, every brushed DC motor has AC flowing through its rotating windings. Current flows through one or more pairs of brushes that bear on the commutator; the brushes connect an external source of electric power to the rotating armature.
The rotating armature consists of one or more coils of wire wound around a laminated, magnetically "soft" ferromagnetic core. Current from the brushes flows through the commutator and one winding of the armature, making it a temporary magnet (an electromagnet). The magnets field produced by the armature interacts with a stationary magnetic field produced by either permanent magnets or another winding a field coil, as part of the motor frame. The force between the two magnetic fields tends to rotate the motor shaft. The commutator switches power to the coils as the rotor turns, keeping the magnetic poles of the rotor from ever fully aligning with the magnetic poles of the stator field, so that the rotor never stops (like a compass needle does), but rather keeps rotating as long as power is applied.
Many of the limitations of the classic commutator DC motor are due to the need for brushes to press against the commutator. This creates friction. Sparks are created by the brushes making and breaking circuits through the rotor coils as the brushes cross the insulating gaps between commutator sections. Depending on the commutator design, this may include the brushes shorting together adjacent sections – and hence coil ends – momentarily while crossing the gaps. Furthermore, the inductance of the rotor coils causes the voltage across each to rise when its circuit is opened, increasing the sparking of the brushes. This sparking limits the maximum speed of the machine, as too-rapid sparking will overheat, erode, or even melt the commutator. The current density per unit area of the brushes, in combination with their resistivity, limits the output of the motor. The making and breaking of electric contact also generates electrical noise; sparking generates RFI. Brushes eventually wear out and require replacement, and the commutator itself is subject to wear and maintenance (on larger motors) or replacement (on small motors). The commutator assembly on a large motor is a costly element, requiring precision assembly of many parts. On small motors, the commutator is usually permanently integrated into the rotor, so replacing it usually requires replacing the whole rotor.
While most commutators are cylindrical, some are flat discs consisting of several segments (typically, at least three) mounted on an insulator.
Large brushes are desired for a larger brush contact area to maximize motor output, but small brushes are desired for low mass to maximize the speed at which the motor can run without the brushes excessively bouncing and sparking. (Small brushes are also desirable for lower cost.) Stiffer brush springs can also be used to make brushes of a given mass work at a higher speed, but at the cost of greater friction losses (lower efficiency) and accelerated brush and commutator wear. Therefore, DC motor brush design entails a trade-off between output power, speed, and efficiency/wear.
DC machines are defined as follows:[67]
- Armature circuit - A winding where the load current is carried, such that can be either stationary or rotating part of motor or generator.
- Field circuit - A set of windings that produces a magnetic field so that the electromagnetic induction can take place in electric machines.
- Commutation: A mechanical technique in which rectification can be achieved, or from which DC can be derived, in DC machines.
There are five types of brushed DC motor:
- DC shunt-wound motor
- DC series-wound motor
- DC compound motor (two configurations):
- Cumulative compound
- Differentially compounded
- Permanent magnet DC motor (not shown)
- Separately excited (not shown)
Ironless or coreless DC motor
Nothing in the principle of any of the motors described above requires that the iron (steel) portions of the rotor actually rotate. If the soft magnetic material of the rotor is made in the form of a cylinder, then (except for the effect of hysteresis) torque is exerted only on the windings of the electromagnets. Taking advantage of this fact is the coreless or ironless DC motor, a specialized form of a brush or brushless DC motor. Optimized for rapid acceleration, these motors have a rotor that is constructed without any iron core. The rotor can take the form of a winding-filled cylinder, or a self-supporting structure comprising only the magnet wire and the bonding material. The rotor can fit inside the stator magnets; a magnetically soft stationary cylinder inside the rotor provides a return path for the stator magnetic flux. A second arrangement has the rotor winding basket surrounding the stator magnets. In that design, the rotor fits inside a magnetically soft cylinder that can serve as the housing for the motor, and likewise provides a return path for the flux.
Because the rotor is much lighter in weight (mass) than a conventional rotor formed from copper windings on steel laminations, the rotor can accelerate much more rapidly, often achieving a mechanical time constant under 1 ms. This is especially true if the windings use aluminum rather than the heavier copper. But because there is no metal mass in the rotor to act as a heat sink, even small coreless motors must often be cooled by forced air. Overheating might be an issue for coreless DC motor designs.
Among these types are the disc-rotor types, described in more detail in the next section.
Vibrator motors for cellular phones are sometimes tiny cylindrical permanent-magnet field types, but there are also disc-shaped types which have a thin multipolar disc field magnet, and an intentionally unbalanced molded-plastic rotor structure with two bonded coreless coils. Metal brushes and a flat commutator switch power to the rotor coils.
Related limited-travel actuators have no core and a bonded coil placed between the poles of high-flux thin permanent magnets. These are the fast head positioners for rigid-disk ("hard disk") drives. Although the contemporary design differs considerably from that of loudspeakers, it is still loosely (and incorrectly) referred to as a "voice coil" structure, because some earlier rigid-disk-drive heads moved in straight lines, and had a drive structure much like that of a loudspeaker.
Permanent-magnet motor
A permanent-magnet motor does not have a field winding on the stator frame, instead relying on permanent magnets to provide the magnetic field against which the rotor field interacts to produce torque. Compensating windings in series with the armature may be used on large motors to improve commutation under load. Because this field is fixed, it cannot be adjusted for speed control. Permanent-magnet fields (stators) are convenient in miniature motors to eliminate the power consumption of the field winding. Most larger DC motors are of the "dynamo" type, which have stator windings. Historically, permanent magnets could not be made to retain high flux if they were disassembled; field windings were more practical to obtain the needed amount of flux. However, large permanent magnets are costly, as well as dangerous and difficult to assemble; this favors wound fields for large machines.
To minimize overall weight and size, miniature permanent-magnet motors may use high energy magnets made with neodymium or other strategic elements; most such are neodymium-iron-boron alloy. With their higher flux density, electric machines with high-energy permanent magnets are at least competitive with all optimally designed singly fed synchronous and induction electric machines. Miniature motors resemble the structure in the illustration, except that they have at least three rotor poles (to ensure starting, regardless of rotor position) and their outer housing is a steel tube that magnetically links the exteriors of the curved field magnets.
Printed armature or pancake DC motor
A rather unusual motor design, the printed armature or pancake motor has the windings shaped as a disc running between arrays of high-flux magnets. The magnets are arranged in a circle facing the rotor with space in between to form an axial air gap. This design is commonly known as the pancake motor because of its extremely flat profile, although the technology has had many brand names since its inception, such as ServoDisc.
The printed armature (originally formed on a printed circuit board) in a printed armature motor is made from punched copper sheets that are laminated together using advanced composites to form a thin rigid disc. The printed armature has a unique construction in the brushed motor world in that it does not have a separate ring commutator. The brushes run directly on the armature surface making the whole design very compact.
An alternative manufacturing method is to use wound copper wire laid flat with a central conventional commutator, in a flower and petal shape. The windings are typically stabilized by being impregnated with electrical epoxy potting systems. These are filled epoxies that have moderate mixed viscosity and a long gel time. They are highlighted by low shrinkage and low exotherm, and are typically UL 1446 recognized as a potting compound for use up to 180°C (Class H) (UL File No. E 210549).
The unique advantage of ironless DC motors is that there is no cogging (torque variations caused by changing attraction between the iron and the magnets). Parasitic eddy currents cannot form in the rotor as it is totally ironless, although iron rotors are laminated. This can greatly improve efficiency, but variable-speed controllers must use a higher switching rate (>40 kHz) or direct current because of the decreased electromagnetic induction.
These motors were originally invented to drive the capstan(s) of magnetic tape drives in the burgeoning computer industry, where minimal time to reach operating speed and minimal stopping distance were critical. Pancake motors are still widely used in high-performance servo-controlled systems, humanoid robotic systems, industrial automation and medical devices. Due to the variety of constructions now available, the technology is used in applications from high temperature military to low cost pump and basic servos.
AC motor
An AC motor has two parts: a stationary stator having coils supplied with alternating current to produce a rotating magnetic field, and a rotor attached to the output shaft that is given a torque by the rotating field.
Induction motor
Cage-rotor induction motor
An induction motor is an asynchronous AC motor where power is transferred to the rotor by electromagnetic induction, much like transformer action. An induction motor resembles a rotating transformer, because the stator (stationary part) is essentially the primary side of the transformer and the rotor (rotating part) is the secondary side. Polyphase induction motors are widely used in industry.
Induction motors may be further divided into squirrel-cage motors and wound-rotor motors. Squirrel-cage motors have a heavy winding made up of solid bars, usually aluminum or copper, joined by rings at the ends of the rotor. When one considers only the bars and rings as a whole, they are much like an animal's rotating exercise cage, hence the name.
Currents induced into this winding provide the rotor magnetic field. The shape of the rotor bars determines the speed-torque characteristics. At low speeds, the current induced in the squirrel cage is nearly at line frequency and tends to be in the outer parts of the rotor cage. As the motor accelerates, the slip frequency becomes lower, and more current is in the interior of the winding. By shaping the bars to change the resistance of the winding portions in the interior and outer parts of the cage, effectively a variable resistance is inserted in the rotor circuit. However, the majority of such motors have uniform bars.
In a wound-rotor motor, the rotor winding is made of many turns of insulated wire and is connected to slip rings on the motor shaft. An external resistor or other control devices can be connected in the rotor circuit. Resistors allow control of the motor speed, although significant power is dissipated in the external resistance. A converter can be fed from the rotor circuit and return the slip-frequency power that would otherwise be wasted back into the power system through an inverter or separate motor-generator.
The wound-rotor induction motor is used primarily to start a high inertia load or a load that requires a very high starting torque across the full speed range. By correctly selecting the resistors used in the secondary resistance or slip ring starter, the motor is able to produce maximum torque at a relatively low supply current from zero speed to full speed. This type of motor also offers controllable speed.
Motor speed can be changed because the torque curve of the motor is effectively modified by the amount of resistance connected to the rotor circuit. Increasing the value of resistance will move the speed of maximum torque down. If the resistance connected to the rotor is increased beyond the point where the maximum torque occurs at zero speed, the torque will be further reduced.
When used with a load that has a torque curve that increases with speed, the motor will operate at the speed where the torque developed by the motor is equal to the load torque. Reducing the load will cause the motor to speed up, and increasing the load will cause the motor to slow down until the load and motor torque are equal. Operated in this manner, the slip losses are dissipated in the secondary resistors and can be very significant. The speed regulation and net efficiency is also very poor.
Various regulatory authorities in many countries have introduced and implemented legislation to encourage the manufacture and use of higher efficiency electric motors. There is existing and forthcoming legislation regarding the future mandatory use of premium-efficiency induction-type motors in defined equipment. For more information, see: Premium efficiency and Copper in energy efficient motors.
Doubly-fed electric motor
Doubly fed electric motors have two independent multiphase winding sets, which contribute active (i.e., working) power to the energy conversion process, with at least one of the winding sets electronically controlled for variable speed operation. Two independent multiphase winding sets (i.e., dual armature) are the maximum provided in a single package without topology duplication. Doubly fed electric motors are machines with an effective constant torque speed range that is twice synchronous speed for a given frequency of excitation. This is twice the constant torque speed range as singly fed electric machines, which have only one active winding set.
A doubly fed motor allows for a smaller electronic converter but the cost of the rotor winding and slip rings may offset the saving in the power electronics components. Difficulties with controlling speed near synchronous speed limit applications.[68]
Singly-fed electric motor
Most AC motors are singly fed. Singly fed electric motors have a single multiphase winding set that is connected to a power supply. Singly fed electric machines may be either induction or synchronous. The active winding set can be electronically controlled. Singly fed electric machines have an effective constant torque speed range up to synchronous speed for a given excitation frequency.
Torque motor
A torque motor (also known as a limited torque motor) is a specialized form of induction motor which can operate indefinitely while stalled, that is, with the rotor blocked from turning, without incurring damage. In this mode of operation, the motor will apply a steady torque to the load (hence the name).
A common application of a torque motor would be the supply- and take-up reel motors in a tape drive. In this application, driven from a low voltage, the characteristics of these motors allow a relatively constant light tension to be applied to the tape whether or not the capstan is feeding tape past the tape heads. Driven from a higher voltage, (and so delivering a higher torque), the torque motors can also achieve fast-forward and rewind operation without requiring any additional mechanics such as gears or clutches. In the computer gaming world, torque motors are used in force feedback steering wheels.
Another common application is the control of the throttle of an internal combustion engine in conjunction with an electronic governor. In this usage, the motor works against a return spring to move the throttle in accordance with the output of the governor. The latter monitors engine speed by counting electrical pulses from the ignition system or from a magnetic pickup and, depending on the speed, makes small adjustments to the amount of current applied to the motor. If the engine starts to slow down relative to the desired speed, the current will be increased, the motor will develop more torque, pulling against the return spring and opening the throttle. Should the engine run too fast, the governor will reduce the current being applied to the motor, causing the return spring to pull back and close the throttle.
Synchronous motor
Brushless DC'''''''''' motor
Some of the problems of the brushed DC motor are eliminated in the brushless design. In this motor, the mechanical "rotating switch" or commutator/brushgear assembly is replaced by an external electronic switch synchronised to the rotor's position. Brushless motors are typically 85–90% efficient or more. Efficiency for a brushless electric motor of up to 96.5% have been reported,[69] whereas DC motors with brushgear are typically 75–80% efficient.
Midway between ordinary DC motors and stepper motors lies the realm of the brushless DC motor. Built in a fashion very similar to stepper motors, these often use a permanent magnet external rotor, three phases of driving coils, may use Hall effect sensors to sense the position of the rotor, and associated drive electronics. The coils are activated, one phase after the other, by the drive electronics as cued by the signals from either Hall effect sensors or from the back EMF (electromotive force) of the undriven coils. In effect, they act as three-phase synchronous motors containing their own variable-frequency drive electronics. A specialized class of brushless DC motor controllers utilize EMF feedback through the main phase connections instead of Hall effect sensors to determine position and velocity. These motors are used extensively in electric radio-controlled vehicles. When configured with the magnets on the outside, these are referred to by modelers as outrunner motors.
Brushless DC motors are commonly used where precise speed control is necessary, as in computer disk drives or in video cassette recorders, the spindles within CD, CD-ROM (etc.) drives, and mechanisms within office products such as fans, laser printers and photocopiers. They have several advantages over conventional motors:
- Compared to AC fans using shaded-pole motors, they are very efficient, running much cooler than the equivalent AC motors. This cool operation leads to much-improved life of the fan's bearings.
- Without a commutator to wear out, the life of a DC brushless motor can be significantly longer compared to a DC motor using brushes and a commutator. Commutation also tends to cause a great deal of electrical and RF noise; without a commutator or brushes, a brushless motor may be used in electrically sensitive devices like audio equipment or computers.
- The same Hall effect sensors that provide the commutation can also provide a convenient tachometer signal for closed-loop control (servo-controlled) applications. In fans, the tachometer signal can be used to derive a "fan OK" signal as well as provide running speed feedback.
- The motor can be easily synchronized to an internal or external clock, leading to precise speed control.
- Brushless motors have no chance of sparking, unlike brushed motors, making them better suited to environments with volatile chemicals and fuels. Also, sparking generates ozone which can accumulate in poorly ventilated buildings risking harm to occupants' health.
- Brushless motors are usually used in small equipment such as computers and are generally used in fans to get rid of unwanted heat.
- They are also acoustically very quiet motors which is an advantage if being used in equipment that is affected by vibrations.
Modern DC brushless motors range in power from a fraction of a watt to many kilowatts. Larger brushless motors up to about 100 kW rating are used in electric vehicles. They also find significant use in high-performance electric model aircraft.
Wound-rotor synchronous motor
A synchronous electric motor is an AC motor distinguished by a rotor spinning with coils passing magnets at the same rate as the alternating current and resulting magnetic field which drives it. Another way of saying this is that it has zero slip under usual operating conditions. Contrast this with an induction motor, which must slip to produce torque. One type of synchronous motor is like an induction motor except the rotor is excited by a DC field. Slip rings and brushes are used to conduct current to the rotor. The rotor poles connect to each other and move at the same speed hence the name synchronous motor. Another type, for low load torque, has flats ground onto a conventional squirrel-cage rotor to create discrete poles. Yet another, such as made by Hammond for its pre-World War II clocks, and in the older Hammond organs, has no rotor windings and discrete poles. It is not self-starting. The clock requires manual starting by a small knob on the back, while the older Hammond organs had an auxiliary starting motor connected by a spring-loaded manually operated switch.
Finally, hysteresis synchronous motors typically are (essentially) two-phase motors with a phase-shifting capacitor for one phase. They start like induction motors, but when slip rate decreases sufficiently, the rotor (a smooth cylinder) becomes temporarily magnetized. Its distributed poles make it act like a permanent-magnet-rotor synchronous motor. The rotor material, like that of a common nail, will stay magnetized, but can also be demagnetized with little difficulty. Once running, the rotor poles stay in place; they do not drift.
Low-power synchronous timing motors (such as those for traditional electric clocks) may have multi-pole permanent-magnet external cup rotors, and use shading coils to provide starting torque. Telechron clock motors have shaded poles for starting torque, and a two-spoke ring rotor that performs like a discrete two-pole rotor.
Variable reluctance motor
Stepper motor
Closely related in design to three-phase AC synchronous motors are stepper motors, where an internal rotor containing permanent magnets or a magnetically soft rotor with salient poles is controlled by a set of external magnets that are switched electronically. A stepper motor may also be thought of as a cross between a DC electric motor and a rotary solenoid. As each coil is energized in turn, the rotor aligns itself with the magnetic field produced by the energized field winding. Unlike a synchronous motor, in its application, the stepper motor may not rotate continuously; instead, it "steps"—starts and then quickly stops again—from one position to the next as field windings are energized and de-energized in sequence. Depending on the sequence, the rotor may turn forwards or backwards, and it may change direction, stop, speed up or slow down arbitrarily at any time.
Simple stepper motor drivers entirely energize or entirely de-energize the field windings, leading the rotor to "cog" to a limited number of positions; more sophisticated drivers can proportionally control the power to the field windings, allowing the rotors to position between the cog points and thereby rotate extremely smoothly. This mode of operation is often called microstepping. Computer controlled stepper motors are one of the most versatile forms of positioning systems, particularly when part of a digital servo-controlled system.
Stepper motors can be rotated to a specific angle in discrete steps with ease, and hence stepper motors are used for read/write head positioning in computer floppy diskette drives. They were used for the same purpose in pre-gigabyte era computer disk drives, where the precision and speed they offered was adequate for the correct positioning of the read/write head of a hard disk drive. As drive density increased, the precision and speed limitations of stepper motors made them obsolete for hard drives—the precision limitation made them unusable, and the speed limitation made them uncompetitive—thus newer hard disk drives use voice coil-based head actuator systems. (The term "voice coil" in this connection is historic; it refers to the structure in a typical (cone type) loudspeaker. This structure was used for a while to position the heads. Modern drives have a pivoted coil mount; the coil swings back and forth, something like a blade of a rotating fan. Nevertheless, like a voice coil, modern actuator coil conductors (the magnet wire) move perpendicular to the magnetic lines of force.)
Stepper motors were and still are often used in computer printers, optical scanners, and digital photocopiers to move the optical scanning element, the print head carriage (of dot matrix and inkjet printers), and the platen or feed rollers. Likewise, many computer plotters (which since the early 1990s have been replaced with large-format inkjet and laser printers) used rotary stepper motors for pen and platen movement; the typical alternatives here were either linear stepper motors or servomotors with closed-loop analog control systems.
So-called quartz analog wristwatches contain the smallest commonplace stepping motors; they have one coil, draw very little power, and have a permanent-magnet rotor. The same kind of motor drives battery-powered quartz clocks. Some of these watches, such as chronographs, contain more than one stepping motor.
Stepper motors were upscaled to be used in electric vehicles under the term SRM (Switched Reluctance Motor). Stepper motors were and still are often used in computer printers, optical scanners, and CNC (Computer Numerically Controlled) machines such as routers, plasma cutters and CNC lathes.
Switched reluctance motor
The switched reluctance motor (SRM) has no brushes or permanent magnets, and the rotor has no electric currents. Instead, torque comes from a slight misalignment of poles on the rotor with poles on the stator. The rotor aligns itself with the magnetic field of the stator, while the stator field stator windings are sequentially energized to rotate the stator field.
The magnetic flux created by the field windings follows the path of least magnetic reluctance, meaning the flux will flow through poles of the rotor that are closest to the energized poles of the stator, thereby magnetizing those poles of the rotor and creating torque. As the rotor turns, different windings will be energized, keeping the rotor turning.
Switched reluctance motors are now being used in some appliances.[70]
Special motors
Electrostatic
An electrostatic motor is based on the attraction and repulsion of electric charge. Usually, electrostatic motors are the dual of conventional coil-based motors. They typically require a high voltage power supply, although very small motors employ lower voltages. Conventional electric motors instead employ magnetic attraction and repulsion, and require high current at low voltages. In the 1750s, the first electrostatic motors were developed by Benjamin Franklin and Andrew Gordon. Today the electrostatic motor finds frequent use in micro-electro-mechanical systems (MEMS) where their drive voltages are below 100 volts, and where moving, charged plates are far easier to fabricate than coils and iron cores. Also, the molecular machinery which runs living cells is often based on linear and rotary electrostatic motors.
Researchers at University of California, Berkeley, recently developed rotational bearings based upon multiwall carbon nanotubes. By attaching a gold plate (with dimensions of the order of 100 nm) to the outer shell of a suspended multiwall carbon nanotube (like nested carbon cylinders), they are able to electrostatically rotate the outer shell relative to the inner core. These bearings are very robust; devices have been oscillated thousands of times with no indication of wear. These nanoelectromechanical systems (NEMS) are the next step in miniaturization and may find their way into commercial applications in the future.
See also:
Piezoelectric
A piezoelectric motor or piezo motor is a type of electric motor based upon the change in shape of a piezoelectric material when an electric field is applied. Piezoelectric motors make use of the converse piezoelectric effect whereby the material produces acoustic or ultrasonic vibrations in order to produce a linear or rotary motion. In one mechanism, the elongation in a single plane is used to make a series stretches and position holds, similar to the way a caterpillar moves.
Sliding rotor motor
A conical-rotor brake motor incorporates the brake as an integral part of the conical sliding rotor. When the motor is at rest, a spring acts on the sliding rotor and forces the brake ring against the brake cap in the motor, holding the rotor stationary. When the motor is energized, its magnetic field generates both an axial and a radial component. The axial component overcomes the spring force, releasing the brake; while the radial component causes the rotor to turn. There is no additional brake control required.
Universal motor
A series-wound motor is referred to as a universal motor when it has been designed to operate on either AC or DC power. It can operate well on AC because the current in both the field and the armature (and hence the resultant magnetic fields) will alternate (reverse polarity) in synchronism, and hence the resulting mechanical force will occur in a constant direction of rotation.
Operating at normal power line frequencies, universal motors are often found in a range less than 1000 watts. Universal motors also form the basis of the traditional railway traction motor in electric railways. In this application, the use of AC to power a motor originally designed to run on DC would lead to efficiency losses due to eddy current heating of their magnetic components, particularly the motor field pole-pieces that, for DC, would have used solid (un-laminated) iron. Although the heating effects are reduced by using laminated pole-pieces, as used for the cores of transformers and by the use of laminations of high permeability electrical steel, one solution available at the start of the 20th century was for the motors to be operated from very low frequency AC supplies, with 25 and 16 2⁄3 Hz (the latter subsequently redesignated 16.7 Hz) operation being common. Because they used universal motors, locomotives using this design could operate from a third rail or overhead wire powered by DC. As well, considering that steam engines directly powered many alternators, their relatively low speeds favored low frequencies because comparatively few stator poles were needed.
An advantage of the universal motor is that AC supplies may be used on motors which have some characteristics more common in DC motors, specifically high starting torque and very compact design if high running speeds are used. The negative aspect is the maintenance and short life problems caused by the commutator. Such motors are used in devices such as food mixers and power tools which are used only intermittently, and often have high starting-torque demands. Continuous speed control of a universal motor running on AC is easily obtained by use of a thyristor circuit, while multiple taps on the field coil provide (imprecise) stepped speed control. Household blenders that advertise many speeds frequently combine a field coil with several taps and a diode that can be inserted in series with the motor (causing the motor to run on half-wave rectified AC).
In the past, repulsion-start wound-rotor motors provided high starting torque, but with added complexity. Their rotors were similar to those of universal motors, but their brushes were connected only to each other. Transformer action induced current into the rotor. Brush position relative to field poles meant that starting torque was developed by rotor repulsion from the field poles. A centrifugal mechanism, when close to running speed, connected all commutator bars together to create the equivalent of a squirrel-cage rotor. As well, when close to operating speed, better motors lifted the brushes out of contact.
Induction motors cannot turn a shaft faster than allowed by the power line frequency. By contrast, universal motors generally run at high speeds, making them useful for appliances such as blenders, vacuum cleaners, and hair dryers where high speed and light weight is desirable. They are also commonly used in portable power tools, such as drills, sanders, circular and jig saws, where the motor's characteristics work well. Many vacuum cleaner and weed trimmer motors exceed 10,000 RPM, while many Dremel and similar miniature grinders exceed 30,000 RPM.
Universal motors also lend themselves to electronic speed control and, as such, are an ideal choice for domestic washing machines. The motor can be used to agitate the drum (both forwards and in reverse) by switching the field winding with respect to the armature. The motor can also be run up to the high speeds required for the spin cycle.
Motor damage may occur from overspeeding (running at a rotational speed in excess of design limits) if the unit is operated with no significant load. On larger motors, sudden loss of load is to be avoided, and the possibility of such an occurrence is incorporated into the motor's protection and control schemes. In some smaller applications, a fan blade attached to the shaft often acts as an artificial load to limit the motor speed to a safe level, as well as a means to circulate cooling airflow over the armature and field windings.
Comparison by major categories
Type | Advantages | Disadvantages | Typical Application | Typical Drive |
---|---|---|---|---|
AC polyphase squirrel-cage or wound-rotor induction motor (SCIM) or (WRIM) | Energy savings Low cost Robust Reliable Ratings to 1+ MW Standardized types. |
High starting current Speed control requires VSD. |
Fixed-speed, traditionally, SCIM the world's workhorse especially in low performance applications of all types Variable-speed, traditionally, low-performance variable-torque pumps, fans, blowers and compressors. Variable-speed, increasingly, other high-performance constant-torque & constant-power or dynamic loads. |
Fixed-speed, low performance applications of all types. Variable-speed, traditionally, wound-rotor induction motor drives or fixed-speed V/Hz-controlled VSDs. Variable-speed, increasingly, vector-controlled VSDs displacing DC, WRIM & single-phase AC induction motor drives. |
AC SCIM split-phase capacitor-start | High power high starting torque |
Speed slightly below synchronous Starting switch or relay required |
Appliances Stationary Power Tools |
Single phase AC |
AC SCIM split-phase capacitor-run | Moderate power High starting torque No starting switch Comparatively long life |
Speed slightly below synchronous Slightly more costly |
Industrial blowers Industrial machinery |
Single phase AC |
AC SCIM split-phase, auxiliary start winding | Moderate power Low starting torque |
Speed slightly below synchronous Starting switch or relay required |
Appliances Stationary Power Tools |
Single phase AC |
AC induction Shaded-pole motor | Low cost Long life |
Speed slightly below synchronous Low starting torque Small ratings low efficiency |
Fans, appliances, record players | Single phase AC |
Universal motor | High starting torque, compact, high speed. | Maintenance (brushes) Shorter lifespan Usually acoustically noisy Only small ratings are economic |
Handheld power tools, blenders, vacuum cleaners, insulation blowers | Single phase AC or DC |
AC Synchronous | Synchronous speed |
More costly | Industrial motors Clocks Audio turntables Tape drives |
Single or Polyphase AC (Capacitor-run for single-phase) |
Stepper DC | Precision positioning High holding torque |
Some can be costly Require a controller |
Positioning in printers and floppy disc drives; industrial machine tools | DC |
Brushless DC | Long lifespan Low maintenance High efficiency |
Higher initial cost Requires a controller |
Rigid ("hard") disk drives CD/DVD players Electric vehicles RC Vehicles UAVs |
DC or PWM |
Switched reluctance motor | Long lifespan Low maintenance High efficiency No permanent magnets Low cost Simple construction |
Requires a controller | Appliances Electric Vehicles Textile mills Aircraft applications |
DC or PWM |
Brushed DC | Simple speed control | Maintenance (brushes) Medium lifespan Costly commutator and brushes |
Steel mills Paper making machines Treadmill exercisers Automotive accessories |
Direct DC or PWM |
Pancake DC | Compact design Simple speed control |
Medium cost Medium lifespan |
Office Equip Fans/Pumps, fast industrial and military servos |
Direct DC or PWM |
Hysteresis motor | Accurate speed control | ? | Tape recorders, hard drive, capstan drive | Single or Polyphase AC |
Back EMF
Since the armature windings of a direct-current motor are moving through a magnetic field, they have a voltage induced in them. This voltage tends to oppose the motor supply voltage and so is called the "back EMF (electromotive force)". The voltage is proportional to the running speed of the motor. The back EMF of the motor, plus the voltage drop across the winding internal resistance and brushes, must equal the voltage at the brushes. This provides the fundamental mechanism of speed regulation in a DC motor. If the mechanical load increases, the motor slows down; a lower back EMF results, and more current is drawn from the supply. This increased current provides the additional torque to balance the new load.
In alternating current machines, it is sometimes useful to consider a back EMF source within the machine; this is of particular concern for close speed regulation of induction motors on variable-frequency drives, for example.
Goodness factor
Professor Eric Laithwaite proposed a metric to determine the 'goodness' of an electric motor:[71]
Where:
- is the goodness factor (factors above 1 are likely to be efficient)
- are the cross sections of the magnetic and electric circuit
- are the lengths of the magnetic and electric circuits
- is the permeability of the core
- is the angular frequency the motor is driven at
From this he showed that the most efficient motors are likely to have relatively large magnetic poles. However, the equation only directly relates to non permanent magnet motors.
Use and types
Standardized electric motors are often used in many modern machines but specific types of electric motors are designed for particular applications.
Rotary
Uses include rotating machines such as fans, turbines, drills, the wheels on electric cars, locomotives and conveyor belts. Also, in many vibrating or oscillating machines, an electric motor spins an unbalanced mass, causing the motor (and its mounting structure) to vibrate. A familiar application is cell phone vibrating alerts used when the acoustic "ringer" is disabled by the user.
Electric motors are also popular in robotics. They turn the wheels of vehicular robots, and servo motors operate arms in industrial robots; they also move arms and legs in humanoid robots. In flying robots, along with helicopters, a motor rotates a propeller, or aerodynamic rotor blades to create controllable amounts of lift.
Electric motors are replacing hydraulic cylinders in airplanes and military equipment.[72][73]
In industrial and manufacturing businesses, electric motors rotate saws and blades in cutting and slicing processes; they rotate parts being turned in lathes and other machine tools, and spin grinding wheels. Fast, precise servo motors position tools and work in modern CNC machine tools. Motor-driven mixers are very common in food manufacturing. Linear motors are often used to push products into containers horizontally.
Many kitchen appliances also use electric motors. Food processors and grinders spin blades to chop and break up foods. Blenders use electric motors to mix liquids, and microwave ovens use motors to turn the tray that food sits on. Toaster ovens also use electric motors to turn a conveyor to move food over heating elements.
Generator
Many electric motors are used as generators, either part (such as regenerative braking) or all of their operational life. When mechanically driven magnetic electric motors produce power due to their back EMF.
Servo motor
A servomotor is a motor, very often sold as a complete module, which is used within a position-control or speed-control feedback control system mainly control valves, such as motor operated control valves. Servomotors are used in applications such as machine tools, pen plotters, and other process systems. Motors intended for use in a servomechanism must have well-documented characteristics for speed, torque, and power. The speed vs. torque curve is quite important and is high ratio for a servo motor. Dynamic response characteristics such as winding inductance and rotor inertia are also important; these factors limit the overall performance of the servomechanism loop. Large, powerful, but slow-responding servo loops may use conventional AC or DC motors and drive systems with position or speed feedback on the motor. As dynamic response requirements increase, more specialized motor designs such as coreless motors are used.
A servo system differs from some stepper motor applications in that the position feedback is continuous while the motor is running; a stepper system relies on the motor not to "miss steps" for short term accuracy, although a stepper system may include a "home" switch or other element to provide long-term stability of control.[74] For instance, when a typical dot matrix computer printer starts up, its controller makes the print head stepper motor drive to its left-hand limit, where a position sensor defines home position and stops stepping. As long as power is on, a bidirectional counter in the printer's microprocessor keeps track of print-head position.
Linear motor
A linear motor is essentially any electric motor that has been "unrolled" so that, instead of producing a torque (rotation), it produces a straight-line force along its length.
Linear motors are most commonly induction motors or stepper motors. Linear motors are commonly found in many roller-coasters where the rapid motion of the motorless railcar is controlled by the rail. They are also used in maglev trains, where the train "flies" over the ground. On a smaller scale, the HP 7225A pen plotter, released in 1978, used two linear stepper motors to move the pen along the X and Y axes.[75]
Spacecraft propulsive motor
An electrically powered spacecraft propulsion system is any of a number of forms of electric motors which spacecraft can employ to gain mechanical energy in outer space. Most of these kinds of spacecraft propulsion work by electrically powering propellant to high speed, but electrodynamic tethers work by interacting with a planet's magnetosphere. [76]
Notes
References
- ^ a b "Zénobe Théophile Gramme". Invent Now, Inc. Hall of Fame profile. Retrieved 2012-09-19.
{{cite conference}}
: Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help) - ^ Laithwaite, E.R. (1975). "Linear electric machines - A personal view". Proceedings of the IEEE. 63 (2): 250–290. doi:10.1109/PROC.1975.9734.
{{cite journal}}
: Unknown parameter|month=
ignored (help) - ^ Faraday, Michael (1822). "On Some New Electro-Magnetical Motion, and on the Theory of Magnetism". Quarterly Journal of Science, Literature and the Arts. XII. Royal Institution of Great Britain: 74-96 (§IX). Retrieved 12 February 2013.
- ^ "The Development of the Electric Motor,". Early Electric Motors. SparkMuseum. Retrieved 12 February 2013.
{{cite conference}}
: Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help) - ^ "The first dinamo?". travelhungary.com. Retrieved 12 February 2013.
- ^ a b Guillemin, Amédée (1891). Electricity and Magnetism. McMillan and Co.
{{cite conference}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ Heller, Augustus (April 1896). "Anianus Jedlik". Nature. 53 (1379). Norman Lockyer: 516.
- ^ Blundel, Stephen J. (2012). Magnetism A Very Short Introduction. Oxford University Press. p. 36. ISBN 978-0-19-960120-2.
- ^ Thein, M. "Elektrische Maschinen in Kraftfahrzeugen (Electric Machines in Motor Vehicles" (PDF) (in German). Retrieved 13 February 2013.
- ^ "Elektrische Chronologie". Elektrisiermaschinen im 18. und 19. Jahrhundert – Ein kleines Lexikon[[Category:Articles containing German-language text]] ("Electrical machinery in the 18th and 19th centuries – a small thesaurus") (in German). University of Regensburg. March 31, 2004. Retrieved August 23, 2010.
{{cite book}}
: URL–wikilink conflict (help) - ^ "History of Batteries (inter alia)". Electropaedia. June 9, 2010. Retrieved August 23, 2010.
- ^ a b "Battery and Energy Technologies, Technology and Applications Timeline". Retrieved 13 February 2013.
- ^ Gee, William (2004). "Sturgeon, William (1783–1850)". Oxford Dictionary of National Biography. Oxford University Press. doi:10.1093/ref:odnb/26748.
- ^ Garrison, Ervan G. (1998). A History of Engineering and Technology: Artful Methods (2nd ed.). CRC Press. ISBN 0-8493-9810-X.
{{cite book}}
: Unknown parameter|accessdata=
ignored (help) - ^ Nye, David E. (1990). Electrifying America: Social Meanings of a New Technology. The MIT Press. ISBN 9780262640305.
{{cite book}}
: Invalid|ref=harv
(help) - ^ "Exhibition on the History of Hungarian Science". Retrieved 13 February 2013.
- ^
Ganot, Adolphe (1881). Elementatry Treatise in Physics (14th ed.). William Wood and Co. pp. 907–908, sec. 899, fig. 888.
{{cite book}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help)[page needed] Provides a superb illustration of one such early electric motor designed by Froment. - ^ "Photo of a traditional form of the St. Louis motor".
- ^ "Buying an Energy-Efficient Electric Motor - Fact Sheet" (PDF). USDoE.
- ^ Babbage, C. (Jan. 1825). "Account of the Repetition of M. Arago's Experiments on the Magnetism Manifested by Various Substances during the Act of Rotation". Philosophical Transactions of the Royal Society of London. 115 (0): 467–496. doi:10.1098/rstl.1825.0023. Retrieved 2 December 2012.
{{cite journal}}
: Check date values in:|date=
(help); Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ Thompson, Silvanus Phillips (1895). Polyphase Electric Currents and Alternate-Current Motors (1st ed.). London: E. & F.N. Spon. p. 261. Retrieved 2 December 2012.
- ^ a b Baily, Walter (June 28, 1879). "A Mode of Producing Arago's Rotation". Taylor & Francis.
{{cite journal}}
: Cite journal requires|journal=
(help); Text "Philosophical magazine: A journal of theoretical, experimental and applied physics" ignored (help) - ^ a b c d e f g h Vučković, Vladan (2006). "Interpretation of a Discovery" (PDF). The Serbian Journal of Electrical Engineers. 3 (2). Retrieved 10 February 2013.
{{cite journal}}
: Unknown parameter|month=
ignored (help) - ^ a b Jonnes, Jill (2004). Empires of Light: Edison, Tesla, Westinghouse, and the Race to Electrify the World. Random House. p. 180.
- ^ Ferraris, G. (1888). Atti della R. Academia delle Science di Torino. XXIII: 360–375.
{{cite journal}}
: Missing or empty|title=
(help); Unknown parameter|book=
ignored (help) - ^ The Case Files: Nikola Tesla. "Two-Phase Induction Motor". The Franklin Institute. Retrieved 2 December 2012.
- ^ "Galileo Ferraris Physicist, Pioneer of Alternating Current Systems (1847-1897) Inventor of the Induction Motor "Father of three-phase current" - Electrotechnical Congress, Frankfurt 1891". Edison Tech Center. Retrieved 3 July 2012.
- ^ Smil, Vaclav (2005). Creating the Twentieth Century:Technical Innovations of 1867-1914 and Their Lasting Impact. Oxford University Press. p. 76. ISBN 978-0-19-988341-7.
- ^ The Froehlich/Kent Encyclopedia of Telecommunications: Volume 17 - Television Technology. CRC Press. 1 December 1998. pp. 37–. ISBN 978-0-8247-2915-8. Retrieved 10 October 2012.
{{cite book}}
:|first=
missing|last=
(help); Text "Froehlich" ignored (help); Text "last" ignored (help) - ^ a b c d e f g h i Drury, Bill (2001). Control Techniques Drives and Controls Handbook. Institution of Electrical Engineers. ISBN 0-86296-793-4.
{{cite book}}
: Check|isbn=
value: checksum (help); Text "page page xiv" ignored (help) - ^ Langsdork, Alexander Suss (1955). Theory of Alternating-Current Machinery (2nd ed.). Tata McGraw-Hill. p. 245. ISBN 0070994234.
{{cite book}}
: Text "lastLangsdorf" ignored (help) - ^ The Encyclopedia Americana. 1977. p. 518.
{{cite book}}
: Text "Volume 19" ignored (help) - ^ a b "Galileo Ferraris". Encyclopædia Britannica.
- ^ "Biography of Galileo Ferraris". Incredible People - Biographies of Famous People.
- ^ a b Neidhöfer, Gerhard. "Early Three-Phase Power (History)". IEEE Power and Energy Magazine. 5 (5): 88–100. doi:10.1109/MPE.2007.904752.
- ^ a b Pansini, Anthony J. (1989). Basic of Electric Motors. Pennwell Publishing Company. p. 45. ISBN 0-13-060070-9.
- ^ a b c d e f Alger, P.L. (1976). "The History of Induction Motors in America". Proceedings of the IEEE. 64 (9): 1380–1383. doi:10.1109/PROC.1976.10329.
{{cite journal}}
:|access-date=
requires|url=
(help); Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ a b Klooster, John W. (30 July 2009). Icons of Invention the Makers of the Modern World from Gutenberg to Gates. Santa Barbara: ABC-CLIO. ISBN 978-0-313-34744-3. Retrieved 10 September 2012.
{{cite book}}
: Unknown parameter|[page=
ignored (help) Cite error: The named reference "Klooster (2009)" was defined multiple times with different content (see the help page). - ^ Day, Lance (1996). Biographical Dictionary of the History of Technology. London: Routledge. p. 1204. ISBN 0-203-02829-5. Retrieved 2 December 2012.
{{cite book}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ Froehlich, Fritz E. Editor-in-Chief (1992). The Froehlich/Kent Encyclopedia of Telecommunications: Volume 17 - Television Technology to Wire Antennas (First ed.). New York: Marcel Dekker, Inc. p. 36. ISBN 0-8247-2902-1. Retrieved 2 December 2012.
{{cite book}}
:|first=
has generic name (help); Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ The Electrical Engineer (21 Sep. 1888). . . . a new application of the alternating current in the production of rotary motion was made known almost simultaneously by two experimenters, Nikola Tesla and Galileo Ferraris, and the subject has attracted general attention from the fact that no commutator or connection of any kind with the armature was required. . . . Vol. Volume II. London: Charles & Co. p. 239.
{{cite book}}
:|volume=
has extra text (help); Check date values in:|year=
(help)CS1 maint: year (link) - ^ Ferraris, Galileo (1885). "Electromagnetic Rotation with an Alternating Current". Electrican. 36: 360–375.
- ^ Tesla, Nikola (1888). "A New System for Alternating Current Motors and Transformers". AIEE. 5: 308–324. Retrieved 17 December 2012.
{{cite journal}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ "Biography of Galileo Ferraris". Incredible People - Biographies of Famous People.
- ^ Harris, William (2008). "How Did Nikola Tesla Change the Way We Use Energy?". Howstuffworks.com. p. 3. Retrieved 10 September 2012.
- ^ Mattox, D. M. (2003). The Foundations of Vacuum Coating Technology. Random House. p. 39. ISBN 0-8155-1495-6.
- ^ Hughes, Thomas Parke. Networks of Power: Electrification in Western society, 1880-1930. Johns Hopkins University Press. p. 117. ISBN 0-8018-2873-2.
- ^ "Timeline of Nikola Tesla". Tesla Society of USA and Canada. Retrieved 5 July 2012.
- ^ Hubbell, M.W. (2011). The Fundamentals of Nuclear Power Generation Questions & Answers. Authorhouse. p. 27. ISBN 978-1463424411.
- ^ VDE Committee History of Electrical Engineering IEEE German Chapter (2012). "150th Birthday of Michael von Dolivo-Dobrowolsky Colloquium". 13. Retrieved 10 February 2013.
{{cite journal}}
: Cite journal requires|journal=
(help); Unknown parameter|month=
ignored (help) - ^ Dolivo-Dobrowolsky, M. (1891). ETZ. 12: 149, 161.
{{cite journal}}
: Missing or empty|title=
(help) - ^ a b c d e f g h i j k l m n o p q r s Doppelbauer, Martin. "A short history of electric motors, 1800-1893". Karlsruhe Institute of Technology. Cite error: The named reference "Doppelbauer" was defined multiple times with different content (see the help page).
- ^ a b c d e f g h i j k l Electropeadia. "Battery and Energy Technologies, Technology and Applications Timeline".
- ^ a b c d e f g h i j k l m n o p Multon, Bernard (June 1995). "Historique des Machines Électromegnétiques et Plus Particulièrement des Machines à Réluctance Variable" (PDF). Revue 3E. I (3): 3–8. Cite error: The named reference "Multon" was defined multiple times with different content (see the help page).
- ^ a b c Martin, Thomas Commerford (1891). The Electric Motor and Its Applications, with an Appendix on 'The Development of the Electric Motor Since 1888' by Louis Bell (3rd ed.). The W.J. Johnston Company, Limited. p. 315 pages.
{{cite book}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help) Cite error: The named reference "Martin" was defined multiple times with different content (see the help page). - ^ "Francois Arago". Encyclopedia Britannica.
- ^ a b c d e f g h i Michalowicz, Joseph C. (Jan. 1948). "Origin of the Electric Motor". Trans. of the AIEE. 67 (2): 1288–1292. doi:10.1109/T-AIEE.1948.5059817.
{{cite journal}}
: Check date values in:|year=
(help)CS1 maint: year (link) - ^ King, H. James (April 1833). "Paper 30: Development of Electrical Technology in the 19th Century: III" (PDF). American Journal of Science, 24: 146; Bulletin 228: Contributions from the Museum of History and Technology, p. 349. p. fig. 21 Pixii magneto generator, without commutator.
{{cite conference}}
: Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help) - ^ a b c d e Boursin, Philippe. "Histoire de la Voiture Électrique".
- ^ Kenyon College Physics Dept. "Froment motors".
- ^ Sprague, Frank J. (May 1934). "Digging in the "Mines of the Motors"". Trans. of AIEE. 53 (5): 695–706. doi:10.1109/T-AIEE.1934.5056690.
- ^ "Variable Speed Pumping, A Guide to Successful Applications, Executive Summary" (PDF). USDOE - Europump - Hydraulic Institute. May 2004. p. 9, Fig. ES-7. Retrieved Feb 19, 2018.
- ^ Bose, Bimal K. (2006). "Chapters 6, 7 & 8". Power Electronics and Motor Drives : Advances and Trends. Academic Press. pp. see esp. 328, 397, 481. ISBN 978-0-12-088405-6.
{{cite conference}}
: Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help) - ^ King, Andy. Electric Machines. U. of Alberta. p. Stepper Motors page. Retrieved 20 February 2013.
- ^ Haymeyer, Kay (2001). "Electrical Machine I: Basics, Design, Function, Operation" (PDF). RWTH Aachen University Institute of Electrical Machines. p. 190. Retrieved 11 January 2013.
- ^ "DC Motor Calculations, part 1". National Instruments. 30 November 2011. Retrieved 7 December 2012.
- ^ Liu, Chen-Ching; et al. (1997). "§66.1 'Generators' in Chapter 66 - 'Electric Machines' of Section 6 - 'Energy'". In Dorf, Richard C. (editor-in-chief) (ed.). The Electrical Engineering Handbook (3rd ed.). CRC Press. p. 1456. ISBN 0-8493-8574-1.
{{cite conference}}
:|editor-first=
has generic name (help); Explicit use of et al. in:|first=
(help); Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help) - ^ Lander, Cyril W. (1993). "§9–8 'Slip Ring Induction Motor Control' in Chapter 9 - A.C. Machine Control". Power electronics (3rd ed.). McGraw-Hill 480 pages. ISBN 0-07-707714-8.
{{cite conference}}
: Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help) - ^ Nozawa, Tetsuo (2009). "Tokai University Unveils 100W DC Motor with 96% Efficiency". Tech-On -- Nikkei Electronics.
{{cite web}}
: CS1 maint: numeric names: authors list (link) - ^ Bush, Steve (2009). "Dyson vacuums 104,000 rpm brushless DC technology". Electronics Weekly Magazine.
{{cite web}}
: CS1 maint: numeric names: authors list (link) - ^ Patterson, D. J. (1-4 June, 2003). The “Goodness” of Small Contemporary Permanent Magnet Electric Machines (PDF). Vol. vol. 2. IEEE. pp. 1195–1200. doi:10.1109/IEMDC.2003.1210392.
{{cite conference}}
:|volume=
has extra text (help); Check date values in:|date=
(help); Unknown parameter|booktile=
ignored (help); Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ Briere, D. (22-24 June, 1993). "Airbus A320/A330/A340 electrical flight controls - A family of fault-tolerant systems" (PDF). FTCS-23. pp. 616–623. doi:10.1109/FTCS.1993.627364.
{{cite conference}}
: Check date values in:|date=
(help); Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help); Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ North, David (Aug. 28, 2000). "Finding Common Ground in Envelope Protection Systems". Aviation Week & Space Technology. 153 (9): 66–68.
{{cite journal}}
: Check date values in:|date=
(help) - ^ Patrick, Dale R. (1997). "Chapter 11". Rotating Electrical Machines and Power Systems (2nd ed.). Fairmont Press, Inc. ISBN 978-0-88173-239-9.
{{cite conference}}
: Unknown parameter|booktitle=
ignored (|book-title=
suggested) (help); Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ Fenoglio, John A. (February 1979). "A High-Quality Digital X-Y Plotter Designed for Reliability, Flexibility and Low Cost" (PDF). Hewlett-Packard Journal. Retrieved 9 February 2012.
{{cite journal}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help) - ^ "Tethers Unlimited".
Bibliography
- Fink, Donald G.; Beaty, H. Wayne, Standard Handbook for Electrical Engineers, `14th ed., McGraw-Hill, 1999, ISBN 0070220050.
- Houston, Edwin J.; Kennelly, Arthur, Recent Types of Dynamo-Electric Machinery, American Technical Book Company 1897, published by P.F. Collier and Sons New York, 1902
- Kuphaldt, Tony R. (2000–2006). "Chapter 13 AC MOTORS". Lessons In Electric Circuits—Volume II.
{{cite book}}
:|access-date=
requires|url=
(help); Cite has empty unknown parameters:|origmonth=
,|month=
,|origdate=
, and|coauthors=
(help); External link in
(help); Unknown parameter|chapterurl=
|chapterurl=
ignored (|chapter-url=
suggested) (help) - Rosenblatt, Jack; Friedman, M. Harold, Direct and Alternating Current Machinery, 2nd ed., McGraw-Hill, 1963
Further reading
- Bedford, B. D. (1964). Principles of Inverter Circuits. John Wiley & Sons, Inc. ISBN 0-471-06134-4.
{{cite book}}
: Unknown parameter|coauthors=
ignored (|author=
suggested) (help)]]) - Bose, Bimal K. (2006). Power Electronics and Motor Drives : Advances and Trends. Academic Press. ISBN 978-0-12-088405-6.
{{cite book}}
: Cite has empty unknown parameter:|1=
(help) - Chiasson, John N., Modeling and High Performance Control of Electric Machines, Wiley-IEEE Press, 2005, ISBN 0-471-68449-X.
- Shanefield, D. J., Industrial Electronics for Engineers, Chemists, and Technicians: With Optional Lab Experiments ,William Andrew Publishing, 2001, ISBN 978-0815514671.
- Fitzgerald, A. E.; Kingsley, Charles, Jr.; Umans, Stephen, Electric Machinery, 6th ed., 2002, ISBN 978-0073660097.
- Pelly, B. R., "Thyristor Phase-Controlled Converters and Cycloconverters: Operation, Control, and Performance", John Wiley, 1971.
See also
Template:Multicol Motor control:
- Adjustable-speed drive
- Electronic speed control
- Motor controller
- Motor protection relay
- Motor soft starter
- Thyristor drive
- Torque and speed of a DC motor
- Variable-frequency drive
- Vector control
Components:
Related subjects:
- Balancing machine
- Blocked rotor test
- Circle diagram
- Electrical engineering
- Electrically powered spacecraft propulsion
- Open circuit test
- Polyphase system
- Power factor
- Power-to-weight ratio
- Traction motor
- Two-phase system
Template:Multicol-break Scientists and engineers:
- André-Marie Ampère
- François Arago
- Walter Baily
- Peter Barlow
- Giuseppe Domenico Botto
- Truman Cook
- Thomas Davenport
- Robert Davidson
- Mikhail Dolivo-Dobrovolsky
- Michael Faraday
- Galileo Ferraris
- Paul-Gustav Froment
- Zénobe Théophile Gramme
- Joseph Henry
- Moritz von Jacobi
- Ányos Jedlik
- Heinrich Friedrich Emil Lenz
- James Clark Maxwell
- Hans Christian Oersted
- Robert H. Park
- Hippolyte Pixii
- Joseph Saxton
- Werner Siemens
- Frank Julian Sprague
- Charles Proteus Steinmetz
- Solomon Stimpson
- William Sturgeon
- Nikola Tesla
External links
- SparkMuseum: Early Electric Motors
- The Invention of the Electric Motor 1800 to 1893, hosted by Karlsrushe Institute of Technology's Martin Doppelbauer
- Electric Motors and Generators, a U. of NSW Physclips multimedia resource
- A Primer on Single-Phase A.C. Electric Motor Horsepower Ratings
- IEA 4E - Efficient Electrical End-Use Equipment.
- iPES Rotating Magnetic Field, animation
- Electric Machines, hosted by U. of Alberta's Andy Knight