A specialised group of PCMs that undergo a solid/solid phase transition with the associated absorption and release of large amounts of heat. These materials change their crystalline structure from one lattice configuration to another at a fixed and well-defined temperature, and the transformation can involve latent heats comparable to the most effective solid/liquid PCMs. Such materials are useful because, unlike solid/liquid PCMs, they do not require nucleation to prevent supercooling. Additionally, because it is a solid/solid phase change, there is no visible change in the appearance of the PCM (other than a slight expansion/contraction), and there are no problems associated with handling liquids, i.e. containment, potential leakage, etc. Currently the range of solid-solid PCM solutions remains from +25°C (77°F) up to +180°C (356°F).
A specialised group of PCMs that undergo a solid/solid phase transition with the associated absorption and release of large amounts of heat. These materials change their crystalline structure from one lattice configuration to another at a fixed and well-defined temperature, and the transformation can involve latent heats comparable to the most effective solid/liquid PCMs. Such materials are useful because, unlike solid/liquid PCMs, they do not require nucleation to prevent supercooling. Additionally, because it is a solid/solid phase change, there is no visible change in the appearance of the PCM (other than a slight expansion/contraction), and there are no problems associated with handling liquids, i.e. containment, potential leakage, etc. Currently the temperature range of solid-solid PCM solutions spans from +25°C (77°F) up to +180°C (356°F).


==Selection criteria==
==Selection criteria==

Revision as of 17:46, 18 April 2017

A sodium acetate heating pad. When the sodium acetate solution crystallises, it becomes warm.
A video showing a „heating pad“ in action

A phase change material (PCM) is a substance with a high heat of fusion which, melting and solidifying at a certain temperature, is capable of storing and releasing large amounts of energy. Heat is absorbed or released when the material changes from solid to liquid and vice versa; thus, PCMs are classified as latent heat storage (LHS) units.

Characteristics and classification

Latent heat storage can be achieved through liquid–>solid, solid–>liquid, solid–>gas and liquid–>gas phase changes. However, only solid–>liquid and liquid–>solid phase changes are practical for PCMs. Although liquid–gas transitions have a higher heat of transformation than solid–liquid transitions, liquid->gas phase changes are impractical for thermal storage because large volumes or high pressures are required to store the materials in their gas phase. Solid–solid phase changes are typically very slow and have a relatively low heat of transformation.

Initially, solid–liquid PCMs behave like sensible heat storage (SHS) materials; their temperature rises as they absorb heat. Unlike conventional SHS materials, however, when PCMs reach the temperature at which they change phase (their melting temperature) they absorb large amounts of heat at an almost constant temperature. The PCM continues to absorb heat without a significant rise in temperature until all the material is transformed to the liquid phase. When the ambient temperature around a liquid material falls, the PCM solidifies, releasing its stored latent heat. A large number of PCMs are available in any required temperature range from −5 up to 190 °C.[1] Within the human comfort range between 20–30 °C, some PCMs are very effective. They store 5 to 14 times more heat per unit volume than conventional storage materials such as water, masonry or rock.[2]

Organic PCMs

Paraffin (CnH2n+2), carbohydrate and lipid derived. [3][4][5]

  • Advantages
    • Freeze without much undercooling
    • Ability to melt congruently
    • Self nucleating properties
    • Compatibility with conventional material of construction
    • No segregation
    • Chemically stable
    • High heat of fusion
    • Safe and non-reactive
    • Recyclable
    • Carbohydrate and lipid based PCMs can be produced from renewable sources
  • Disadvantages
    • Low thermal conductivity in their solid state. High heat transfer rates are required during the freezing cycle
    • Volumetric latent heat storage capacity can be low
    • Flammable. This can be partially alleviated by specialist containment
    • To obtain reliable phase change points, most manufacturers use technical grade paraffins which are essentially paraffin mixture(s) and are completely refined of oil, resulting in high costs

Inorganic

Salt hydrates (MnH2O)[6]

  • Advantages
    • High volumetric latent heat storage capacity
    • Availability and low cost
    • Sharp melting point
    • High thermal conductivity
    • High heat of fusion
    • Non-flammable
  • Disadvantages
    • Change of volume is very high
    • Super cooling is major problem in solid–liquid transition
    • Nucleating agents are needed and they often become inoperative after repeated cycling
      Infinite R Energy Sheet
      [7]Example eutectic salt hydrate PCM with nucleation & gelling agents for long term thermal stability and thermoplastic foil macro-encapsulation physical durability. Applied for passive temperature stabilization to result in building HVAC energy conservation.

Eutectics

c-inorganic, inorganic-inorganic compounds

  • Advantages
    • Eutectics have sharp melting point similar to pure substance
    • Volumetric storage density is slightly above organic compounds
    • Extra water principle can be used to avoid phase change degradation, involving dissolving the anhydrous salt during melting to result in a thickening of the liquid material so that it melts to a gel form
  • Disadvantages
    • Only limited data is available on thermo-physical properties as the use of these materials are relatively new to thermal storage application

Hygroscopic materials

Many natural building materials are hygroscopic, that is they can absorb (water condenses) and release water (water evaporates). The process is thus:

  • Condensation (gas to liquid) ΔH<0; enthalpy decreases (exothermic process) gives off heat.
  • Vaporization (liquid to gas) ΔH>0; enthalpy increases (endothermic process) absorbs heat (or cools).

Whilst this process liberates a small quantity of energy, large surfaces area allows significant (1–2 °C) heating or cooling in buildings. The corresponding materials are wool insulation, earth/clay render finishes,.


Solid-Solid PCM Materials

A specialised group of PCMs that undergo a solid/solid phase transition with the associated absorption and release of large amounts of heat. These materials change their crystalline structure from one lattice configuration to another at a fixed and well-defined temperature, and the transformation can involve latent heats comparable to the most effective solid/liquid PCMs. Such materials are useful because, unlike solid/liquid PCMs, they do not require nucleation to prevent supercooling. Additionally, because it is a solid/solid phase change, there is no visible change in the appearance of the PCM (other than a slight expansion/contraction), and there are no problems associated with handling liquids, i.e. containment, potential leakage, etc. Currently the temperature range of solid-solid PCM solutions spans from +25°C (77°F) up to +180°C (356°F).

Selection criteria

Thermodynamic properties. The phase change material should possess:[8]

  • Melting temperature in the desired operating temperature range
  • High latent heat of fusion per unit volume
  • High specific heat, high density and high thermal conductivity
  • Small volume changes on phase transformation and small vapor pressure at operating temperatures to reduce the containment problem
  • Congruent melting
  • Kinetic properties
  • High nucleation rate to avoid supercooling of the liquid phase
  • High rate of crystal growth, so that the system can meet demands of heat recovery from the storage system
  • Chemical properties
  • Chemical stability
  • Complete reversible freeze/melt cycle
  • No degradation after a large number of freeze/melt cycle
  • Non-corrosiveness, non-toxic, non-flammable and non-explosive materials
  • Economic properties
  • Low cost
  • Availability

Thermophysical properties

Common PCMs

Material
Organic
PCM
Melting
point

oC
Heat of
fusion

kJ·kg−1
Heat of
fusion

MJ·m−3
Specific heat, cp
solid
kJ·kg−1·K−1
Specific heat, cp
liquid
kJ·kg−1·K−1
Density, ρ
solid
kg·m−3
Density, ρ
liquid
kg·m−3
Thermal conductivity, k
solid
W·m−1·K−1
Thermal conductivity, k
'liquid'
W·m−1·K−1
VHC
solid
kJ·m−3·K−1
VHC
liquid
kJ·m−3·K−1
Thermal effusivity, e
solid
J·m−2·K−1·s−1/2
Cost
USD·kg−1
Water No 0 333.6 319.8 2.05 4.186 917 1,000 1.6[9]-2.22[10] 1,880 4,186 1,890 0.003125[11]
Sodium sulfate (Na2SO4·10H2O) No 32.4 252 0.05 [12]
NaCl·Na2SO4·10H2O No 18 286 0.05 [12]
Lauric acid Yes[13][14] 44.2[15] 211.6 197.7 1.76 2.27 1,007 862 1,772 1,957 1.6 [16][17]
TME(63%w/w)+H2O(37%w/w) Yes[13][14] 29.8 218.0 240.9 2.75 3.58 1,120 1,090 3,080 3,902
Mn(NO3)2·6H2O+MnCl2·4H2O(4%w/w) No[18][19] 15–25 125.9 221.8 2.34 2.78 1,795 1,728 4,200 4,804
Na2SiO3·5H2O No[18][19] 72.20 267.0 364.5 3.83 4.57 1,450 1,280 0.103−0.128[20] 5,554 5,850 801 8.04[21]
Aluminium No 660.32 396.9 1,007.2 0.8969 2,700 2,375 237[22][23] 2,422 ? 23,960 2.04626[24]
Copper No 1,084.62 208.7 1,769.5 0.3846 8,940 8,020 401[25] 3,438 ? 37,130 6.81256[26]
Gold No 1,064.18 63.72 1,166.3 0.129 19,300 17,310 318[27] 2,491 28,140 34,297.8[26]
Iron No 1,538 247.3 1,836.6 0.4495 7,874 6,980 80.4[28] 3,539 16,870 0.3248[29]
Lead No 327.46 23.02 253.2 0.1286 11,340 10,660 35.3[30] 1,459 7,180 2.1151[26]
Lithium No 180.54 432.2 226.0 3.5816 534 512 84.8[31] 1,913 12,740 62.2164[32]
Silver No 961.78 104.6 1,035.8 0.235 10,490 9,320 429[33] 2,465 32,520 492.524[26]
Titanium No 1,668 295.6 1,273.5 0.5235 4,506 4,110 21.9[34] 2,359 7,190 8.0469[35]
Zinc No 419.53 112.0 767.5 0.3896 7,140 6,570 116[36] 2,782 17,960 2.15735[26]
No 310 174 [37]
No 282 212 [37]
NaOH No 318 158 [37]
No 337 116 [37]
KOH No 360 167 [37]
NaOH/ (7.2%) No 283 340 [37]
NaCl(26.8%)/NaOH No 370 370 [37]
NaCl/KCL(32.4%)/LiCl(32.8%) No 346 281 [37]
NaCl(5.7%) / (85.5%) / No 287 176 [37]
NaCl / (5.0%) No 284 171 [37]
NaCl(5.0%)/ No 282 212 [37]
NaCl(42.5%)/KCl(20.5)/ No 385-393 410 [37]
No 290 170 [37]
/KCl(4.5%) No 320 150 [37]
/KBr(4.7%)/KCl(7.3%) No 342 140 [37]
Paraffin 14-Carbons [38] Yes 5.5 228
Paraffin 15-Carbons [38] Yes 10 205
Paraffin 16-Carbons [38] Yes 16.7 237.1
Paraffin 17-Carbons [38] Yes 21.7 213
Paraffin 18-Carbons [38] Yes 28 244
Paraffin 19-Carbons [38] Yes 32 222
Paraffin 20-Carbons [38] Yes 36.7 246
Paraffin 21-Carbons [38] Yes 40.2 200
Paraffin 22-Carbons [38] Yes 44 249
Paraffin 23-Carbons [38] Yes 47.5 232
Paraffin 24-Carbons [38] Yes 50.6 255
Paraffin 25-Carbons [38] Yes 49.4 238
Paraffin 26-Carbons [38] Yes 56.3 256
Paraffin 27-Carbons [38] Yes 58.8 236
Paraffin 28-Carbons [38] Yes 61.6 253
Paraffin 29-Carbons [38] Yes 63.4 240
Paraffin 30-Carbons [38] Yes 65.4 251
Paraffin 31-Carbons [38] Yes 68 242
Paraffin 32-Carbons [38] Yes 69.5 170
Paraffin 33-Carbons [38] Yes 73.9 268
Paraffin 34-Carbons [38] Yes 75.9 269
Formic acid [38] Yes 7.8 247
Caprilic acid [38] Yes 16.3 149
Glycerin [38] Yes 17.9 198.7
p-Lattic acid [38] Yes 26 184
Methyl palmitate [38] Yes 29 205
Camphenilone [38] Yes 39 205
Docasyl bromide [38] Yes 40 201
Caprylone [38] Yes 40 259
Phenol [38] Yes 41 120
Heptadecanone [38] Yes 41 201
1-Cyclohexylooctadecane [38] Yes 41 218
4-Heptadacanone [38] Yes 41 197
p-Joluidine [38] Yes 43.3 167
Cyanamide [38] Yes 44 209
Methyl eicosanate [38] Yes 45 230
3-Heptadecanone [38] Yes 48 218
2-Heptadecanone [38] Yes 48 218
Hydrocinnamic acid [38] Yes 48 118
Cetyl acid [38] Yes 49.3 141
α-Nepthylamine [38] Yes 59 93
Camphene [38] Yes 50 238
O-Nitroaniline [38] Yes 50 93
9-Heptadecanone [38] Yes 51 213
Thymol [38] Yes 51.5 115
Methyl behenate [38] Yes 52 234
Diphenyl amine [38] Yes 52.9 107
p-Dichlorobenzene [38] Yes 53.1 121
Oxolate [38] Yes 54.3 178
Hypophosphoric acid [38] Yes 55 213
O-Xylene dichloride [38] Yes 55 121
β-Chloroacetic acid [38] Yes 56 147
Chloroacetic acid [38] Yes 56 130
Nitro napthalene [38] Yes 56.7 103
Trimyristin [38] Yes 33 201
Heptaudecanoic acid [38] Yes 60.6 189
α-Chloroacetic acid [38] Yes 61.2 130
Bees wax [38] Yes 61.8 177
Glyolic acid [38] Yes 63 109
Glycolic acid [38] Yes 63 109
p-Bromophenol [38] Yes 63.5 86
Azobenzene [38] Yes 67.1 121
Acrylic acid [38] Yes 68 115
Dinto toluent (2,4) [38] Yes 70 111
Phenylacetic acid [38] Yes 76.7 102
Thiosinamine [38] Yes 77 140
Bromcamphor [38] Yes 77 174
Durene [38] Yes 79.3 156
Methly brombenzoate [38] Yes 81 126
Alpha napthol [38] Yes 96 163
Glautaric acid [38] Yes 97.5 156
p-Xylene dichloride [38] Yes 100 138.7
Catechol [38] Yes 104.3 207
Quinone [38] Yes 115 171
Actanilide [38] Yes 118.9 222
Succinic anhydride [38] Yes 119 204
Benzoic acid [38] Yes 121.7 142.8
Stibene [38] Yes 124 167
Benzamide [38] Yes 127.2 169.4
Acetic acid [38] Yes 16.7 184
Polyethylene glycol 600 [38] Yes 20 146
Capric acid [38] Yes 36 152
Eladic acid [38] Yes 47 218
Pentadecanoic acid [38] Yes 52.5 178
Tristearin [38] Yes 56 191
Myristic acid [38] Yes 58 199
Palmatic acid [38] Yes 55 163
Stearic acid [38] Yes 69.4 199
Acetamide [38] Yes 81 241
Methyl fumarate [38] Yes 102 242

Volumetric heat capacity (VHC) J·m−3·K−1

Thermal inertia (I) = Thermal effusivity (e) J·m−2·K−1·s−1/2

Commercially available PCMs near room temperature

Material Supplier Type Form Melting
temperature, Tm

oC
Melting
temperature, Tm

oF
, Enthalpy

ΔH
kJ/kg

Solid Density, ρ
kg/m3
Liquid Density, ρ
kg/m3
Solid Thermal
conductivity, k
W/m·K
Liquid Thermal
conductivity, k

W/m·K
Solid Specific
heat, cp

kJ/kg·K
Liquid Specific
heat, cp

kJ/kg·K
18 C⁰ Infinite R Energy Sheet Insolcorp[39] Inorganic Macro-encapsulated 18 64.4 200 1540 0.54 1.09 3.14
21 C⁰ Infinite R Energy Sheet Insolcorp[39] Inorganic Macro-encapsulated 21 69.8 200 1540 0.54 1.09 3.14
23 C⁰ Infinite R Energy Sheet Insolcorp[39] Inorganic Macro-encapsulated 23 73.4 200 1540 0.54 1.09 3.14
25 C⁰ Infinite R Energy Sheet Insolcorp[39] Inorganic Macro-encapsulated 25 77 200 1540 0.54 1.09 3.14
29 C⁰ Infinite R Energy Sheet Insolcorp[39] Inorganic Macro-encapsulated 29 84.2 200 1540 0.54 1.09 3.14
savE [40] HS 33N[41] Pluss[42] Inorganic Bulk -30 -22 224 1425
savE HS 26N[43] Pluss Inorganic Bulk -24 -11.2 222 1200 3.6
savE HS 23N[44] Pluss Inorganic Bulk -20 -4 210 1140 0.7 4.9 3.4
savE HS 18N[45] Pluss Inorganic Bulk -18 -0.4 242 1095 0.44
savE HS 15N[46] Pluss Inorganic Bulk -15 5 280 1070 0.53 5.26 3.4
savE HS 10N[47] Pluss Inorganic Bulk -10 14 230 1125 0.60 4.25 0.96
savE HS 7N[48] Pluss Inorganic Bulk -6 21.2 230 1120 0.55 1.76 3.2
savE Frost/HS 01[49] Pluss Inorganic Bulk 1 33.8 290 1010 0.55 2.2 3.9
savE OM 03[50] Pluss Organic Bulk 3.5 38.3 240 835 0.146 0.22 3
savE FS 03[51] Pluss Organic Bulk 3.6 38.48 214 0.16
savE OM 05[52] Pluss Organic Bulk 5.5 41.9 130 845 0.135 0.3 2.37
savE FS 05[53] Pluss Organic Bulk 5.9 42.62 110 0.134
savE OM 08[54] Pluss Organic Bulk 9 48.2 220 1050 0.168 0.235 3.1
savE OM 11[55] Pluss Organic Bulk 9.5 49.1 240 1060 0.118 0.235
savE OM 21[56] Pluss Organic Bulk 21 69.8 250 924 0.14 0.21 2.6
savE FS 21[57] Pluss Organic Bulk 21 69.8 130 0.3
savE HS 21[58] Pluss Inorganic Bulk 22 71.6 185 1400 0.59 0.82 3.4
savE HS 22[59] Pluss Inorganic Bulk 23 73.4 185 1540 0.56 1.13 3.04
savE HS 24[60] Pluss Inorganic Bulk 25 77 185 1510 0.55 1.05 2.3
savE HS 29[61] Pluss Inorganic Bulk 29 84.2 190 1530 0.382 0.478 2.3
savE OM 29[62] Pluss Organic Bulk 29 84.2 229 870 0.172 0.293 3.9
savE FS 29[63] Pluss Organic Bulk 29 84.2 189 0.45
savE OM 30[64] Pluss Organic Bulk 31 87.8 200 878 0.123 0.185 2.6
savE FS 30[65] Pluss Organic Bulk 31 87.8 170 0.496
savE OM 32[66] Pluss Organic Bulk 32 89.6 200 870 0.145 0.219
savE HS 34[67] Pluss Inorganic Bulk 35 95 150 1850 0.47 0.5 2.4
savE OM 35[68] Pluss Organic Bulk 37 98.6 197 870 0.16 0.2
savE OM 37[69] Pluss Organic Bulk 37 98.6 210 860 0.13 0.16
savE OM 46[70] Pluss Organic Bulk 46 114.8 250 880 0.1 0.2
savE OM 48[71] Pluss Organic Bulk 48 118.4 275 875 0.12 0.2
savE OM 50[72] Pluss Organic Bulk 50.3 122.54 250 850 0.14 0.21 3.05
savE OM 55[73] Pluss Organic Bulk 55 131 210 840 0.1 0.16 3.05
savE OM 65[74] Pluss Organic Bulk 67 152.6 183 924 0.33 0.19 2.38
savE FSM 65[75] Pluss Organic Bulk 67 152.6 150 845 0.25
savE HS 89[76] Pluss Inorganic Bulk 87 188.6 180 1630
PureTemp -37[77] Entropy Solutions Organic Bulk -37 -35 147 880 1.39
PureTemp -23 Entropy Solutions Organic Bulk -23 -9 145 860 2.11
PureTemp -21[78] Entropy Solutions Organic Bulk -21 -6 240 1060 1.83
PureTemp -17 PureTemp Organic Bulk -17 1 145 860 1.74
PureTemp -15 PureTemp Organic Bulk -15 5 286 1030 1.84
PureTemp -12 PureTemp Organic Bulk -12 10 168 870 1.86
PureTemp -5 PureTemp Organic Bulk -5 23 150 860 1.66
PureTemp 1 PureTemp Organic Bulk 1 34 300 1000 2.32
PureTemp 4 PureTemp Organic Bulk 4 39 195 880 2.44
PureTemp 6 PureTemp Organic Bulk 6 43 170 860 1.56
PureTemp 8 PureTemp Organic Bulk 8 46 180 860 1.85
PureTemp 12 PureTemp Organic Bulk 12 54 185 860 1.76
PureTemp 15 PureTemp Organic Bulk 15 59 165 860 2.25
PureTemp 18 PureTemp Organic Bulk 18 64 189 860 1.47
PureTemp 20 PureTemp Organic Bulk 20 68 180 860 2.59
PureTemp 23 PureTemp Organic Bulk 23 73 203 830 1.84
PureTemp 24 PureTemp Organic Bulk 24 75 185 860 2.85
PureTemp 25 PureTemp Organic Bulk 25 77 185 860 1.99
PureTemp 27 PureTemp Organic Bulk 27 81 200 860 2.46
PureTemp 28 PureTemp Organic Bulk 29 84 205 860 2.34
PureTemp 29 PureTemp Organic Bulk 29 84 189 850 1.77
PureTemp 33 PureTemp Organic Bulk 33 91 185 850 2.34
PureTemp 35 PureTemp Organic Bulk 35 95 180 850 2.44
PureTemp 37 PureTemp Organic Bulk 38 100 222 840 2.21
PureTemp 48 PureTemp Organic Bulk 52 126 245 820 2.1
PureTemp 53 PureTemp Organic Bulk 53 127 225 990 2.36
PureTemp 58 PureTemp Organic Bulk 58 136 237 810 2.47
PureTemp 60 PureTemp Organic Bulk 61 142 230 870 2.04
PureTemp 63 PureTemp Organic Bulk 63 145 199 840 1.99
PureTemp 68 PureTemp Organic Bulk 68 154 198 870 1.85
PureTemp 103 PureTemp Organic Bulk 103 217 157 1220 2.09
PureTemp 151 PureTemp Organic Bulk 151 304 170 1360 2.06
Astorstat HA 17 Honey well [79] Organic Bulk 21.7 71
Astorstat HA 18 Honey well Organic Bulk 27.2 81
RT26 Rubitherm GmbH [80] Organic Bulk 24 75 232
RT27 Rubitherm GmbH Organic Bulk 28 82 206
Climsel C -21 Climator [81] Inorganic Bulk -21 -6 288 1300 0.6 3.6
Climsel C -18 Climator Inorganic Bulk -18 0 288 1300 0.6 3.6
Climsel C 7 Climator Inorganic Bulk 7 45 126 1400 0.6 3.6
Climsel C 10 Climator Inorganic Bulk 10.5 51 126 1400 0.6 3.6
Climsel C 21 Climator Inorganic Bulk 21 70 112 1380 0.6 3.6
Climsel C24 Climator Inorganic Bulk 24 75 151.3 1380 0.6 3.6
Climsel C28 Climator Inorganic Bulk 28 82 162.3 1420 0.6 3.6
Climsel C32 Climator Inorganic Bulk 32 90 162.3 1420 0.6 3.6
Climsel C48 Climator Inorganic Bulk 48 118 180 1360 0.6 3.6
Climsel C58 Climator Inorganic Bulk 58 136 288.5 1460 0.6 1.89
Climsel C70 Climator Inorganic Bulk 70 158 282.9 1400 0.6 3.6
STL27 Mitsubishi Chemicals [82] Inorganic Bulk 27 81 213
S27 Cristopia [83] Inorganic Bulk 27 81 207
TH 29 TEAP [84] Inorganic Bulk 29 84 188
RT 20 Rubitherm GmbH Organic Bulk 22 72 172
Climsel C23 Climator Inorganic Bulk 23 73 148 32
RT 26 Rubitherm GmbH Organic Bulk 25 77 131
STL 27 Mitsubishi Chemicals Inorganic Bulk 27 81 213
RT 30 Rubitherm GmbH Organic Bulk 28 82 206
RT 32 Rubitherm GmbH Organic Bulk 21 70 130
DS 5000 Micronal [85] Micro-encapsulated 26 79 45
DS 5007 Micronal Micro-encapsulated 23 73 41
DS 5030 Micronal Micro-encapsulated 21 70 37
DS 5001 Micronal Micro-encapsulated 26 79 110
DS 5008 Micronal Micro-encapsulated 23 73 100
DS 5029 Micronal Micro-encapsulated 21 70 90
RT -9 HC Rubitherm GmbH Organic Bulk -9 16 260
RT -4 Rubitherm GmbH Organic Bulk -4 25 179
RT 0 Rubitherm GmbH Organic Bulk 0 32 225
RT 2 HC Rubitherm GmbH Organic Bulk 2 36 205
RT 3 Rubitherm GmbH Organic Bulk 3 37 198
RT 3 HC Rubitherm GmbH Organic Bulk 3 37 250
RT 4 Rubitherm GmbH Organic Bulk 4 39 182
RT 5 Rubitherm GmbH Organic Bulk 5 41 180
RT 5 HC Rubitherm GmbH Organic Bulk 5 41 240
RT 6 Rubitherm GmbH Organic Bulk 6 43 175
RT 8 Rubitherm GmbH Organic Bulk 8 46 180
RT 9 Rubitherm GmbH Organic Bulk 9 48 160
RT 10 Rubitherm GmbH Organic Bulk 10 50 150
RT 10 HC Rubitherm GmbH Organic Bulk 10 50 195
RT 11 HC Rubitherm GmbH Organic Bulk 11 52 190
RT 12 Rubitherm GmbH Organic Bulk 12 54 150
RT 15 Rubitherm GmbH Organic Bulk 15 59 140
RT 18 HC Rubitherm GmbH Organic Bulk 18 64 250
RT 21 Rubitherm GmbH Organic Bulk 21 70 160
RT 21 HC Rubitherm GmbH Organic Bulk 21 70 190
RT 22 HC Rubitherm GmbH Organic Bulk 22 72 200
RT 24 Rubitherm GmbH Organic Bulk 24 75 150
RT 25 Rubitherm GmbH Organic Bulk 25 77 148
RT 25 HC Rubitherm GmbH Organic Bulk 25 77 230
RT 27 Rubitherm GmbH Organic Bulk 27 81 179
RT 28 HC Rubitherm GmbH Organic Bulk 28 82 245
RT 31 Rubitherm GmbH Organic Bulk 31 88 170
RT 35 Rubitherm GmbH Organic Bulk 35 95 170
RT 35 HC Rubitherm GmbH Organic Bulk 35 95 240
RT 42 Rubitherm GmbH Organic Bulk 42 108 174
RT 44 HC Rubitherm GmbH Organic Bulk 44 111 255
RT 47 Rubitherm GmbH Organic Bulk 47 117 170
RT 50 Rubitherm GmbH Organic Bulk 50 122 168
RT 52 Rubitherm GmbH Organic Bulk 52 126 173
RT 55 Rubitherm GmbH Organic Bulk 55 131 172
RT 58 Rubitherm GmbH Organic Bulk 58 136 160
RT 60 Rubitherm GmbH Organic Bulk 60 140 144
RT 62 Rubitherm GmbH Organic Bulk 62 144 146
RT 65 Rubitherm GmbH Organic Bulk 65 149 152
RT 70 HC Rubitherm GmbH Organic Bulk 70 158 230
RT 80 HC Rubitherm GmbH Organic Bulk 79 174 240
RT 82 Rubitherm GmbH Organic Bulk 82 180 176
RT 90 HC Rubitherm GmbH Organic Bulk 90 194 200
S117 PlusICE [86] Inorganic Bulk 117 243 160 1450 0.7 2.61
S89 PlusICE Inorganic Bulk 89 192 151 1550 0.67 2.48
S83 PlusICE Inorganic Bulk 83 181 141 1600 0.62 2.31
S72 PlusICE Inorganic Bulk 72 162 127 1666 0.58 2.13
S70 PlusICE Inorganic Bulk 70 158 110 1680 0.57 2.1
S58 PlusICE Inorganic Bulk 58 136 145 1505 0.69 2.55
S50 PlusICE Inorganic Bulk 50 122 100 1601 0.43 1.59
S46 PlusICE Inorganic Bulk 46 115 210 1587 0.45 2.41
S44 PlusICE Inorganic Bulk 44 111 100 1584 0.43 1.61
S34 PlusICE Inorganic Bulk 34 93 115 2100 0.52 2.1
S32 PlusICE Inorganic Bulk 32 90 200 1460 0.51 1.91
S30 PlusICE Inorganic Bulk 30 86 190 1304 0.48 1.9
S27 PlusICE Inorganic Bulk 27 81 183 1530 0.54 2.2
S25 PlusICE Inorganic Bulk 25 77 180 1530 0.54 2.2
S23 PlusICE Inorganic Bulk 23 73 175 1530 0.54 2.2
S21 PlusICE Inorganic Bulk 22 72 170 1530 0.54 2.2
S19 PlusICE Inorganic Bulk 19 66 160 1520 0.43 1.9
S17 PlusICE Inorganic Bulk 17 63 160 1525 0.43 1.9
S15 PlusICE Inorganic Bulk 15 59 160 1510 0.43 1.9
S13 PlusICE Inorganic Bulk 13 55 160 1515 0.43 1.9
S10 PlusICE Inorganic Bulk 10 50 155 1470 0.43 1.9
S8 PlusICE Inorganic Bulk 8 46 150 1475 0.44 1.9
S7 PlusICE Inorganic Bulk 7 45 150 1700 0.4 1.85
A164 PlusICE Organic Bulk 164 327 290 1500 2.42
A155 PlusICE Organic Bulk 155 311 100 900 0.23 2.2
A144 PlusICE Organic Bulk 144 291 115 880 0.23 2.2
A133 PlusICE Organic Bulk 133 271 126 880 0.23 2.2
A118 PlusICE Organic Bulk 118 244 340 1450 2.7
A95 PlusICE Organic Bulk 95 203 205 900 0.22 2.2
A82 PlusICE Organic Bulk 82 180 155 850 0.22 2.21
A70 PlusICE Organic Bulk 70 158 173 890 0.23 2.2
A62 PlusICE Organic Bulk 62 144 145 910 0.22 2.2
A60H PlusICE Organic Bulk 60 140 212 800 0.18 2.15
A60H PlusICE Organic Bulk 60 140 145 910 0.22 2.22
A58H PlusICE Organic Bulk 58 136 243 820 0.18 2.85
A58 PlusICE Organic Bulk 58 136 132 910 0.22 2.22
A55 PlusICE Organic Bulk 55 131 135 905 0.22 2.22
A53H PlusICE Organic Bulk 53 127 166 810 0.18 2.02
A53H PlusICE Organic Bulk 53 127 130 910 0.22 2.22
A52 PlusICE Organic Bulk 52 126 222 810 0.18 2.15
A50 PlusICE Organic Bulk 50 122 218 810 0.18 2.15
A48 PlusICE Organic Bulk 48 118 234 810 0.18 2.85
A46 PlusICE Organic Bulk 46 115 155 910 0.22 2.22
A44 PlusICE Organic Bulk 44 111 242 805 0.18 2.15
A43 PlusICE Organic Bulk 43 109 165 780 0.18 2.37
A42 PlusICE Organic Bulk 42 108 105 905 0.21 2.22
A40 PlusICE Organic Bulk 40 104 230 810 0.18 2.43
A39 PlusICE Organic Bulk 39 102 105 900 0.22 2.22
A37 PlusICE Organic Bulk 37 99 235 810 0.18 2.85
A36 PlusICE Organic Bulk 36 97 217 790 0.18 2.37
A32 PlusICE Organic Bulk 32 90 130 845 0.21 2.2
A29 PlusICE Organic Bulk 29 84 225 810 0.18 2.15
A28 PlusICE Organic Bulk 28 82 155 789 0.21 2.22
A26 PlusICE Organic Bulk 26 79 150 790 0.21 2.22
A25H PlusICE Organic Bulk 25 77 226 810 0.18 2.15
A25 PlusICE Organic Bulk 25 77 150 785 0.18 2.26
A24 PlusICE Organic Bulk 24 75 145 790 0.18 2.22
A23 PlusICE Organic Bulk 23 73 145 785 0.18 2.22
A22H PlusICE Organic Bulk 22 72 216 820 0.18 2.85
A22 PlusICE Organic Bulk 22 72 145 785 0.18 2.22
A17 PlusICE Organic Bulk 17 63 150 785 0.18 2.22
A16 PlusICE Organic Bulk 16 61 213 760 0.18 2.37
A15 PlusICE Organic Bulk 15 59 130 790 0.18 2.26
A9 PlusICE Organic Bulk 9 48 140 775 0.21 2.16
A8 PlusICE Organic Bulk 8 46 150 773 0.21 2.16
A6 PlusICE Organic Bulk 6 43 150 770 0.21 2.17
A4 PlusICE Organic Bulk 4 39 200 766 0.21 2.18
A3 PlusICE Organic Bulk 3 37 200 765 0.21 2.2
A2 PlusICE Organic Bulk 2 36 200 765 0.21 2.2
E0 PlusICE Eutectic Bulk 0 32 332 1000 0.58 4.19
E-2 PlusICE Eutectic Bulk -2 28 306 1070 0.58 3.8
E-3 PlusICE Eutectic Bulk -3.7 25 312 1060 0.6 3.84
E-6 PlusICE Eutectic Bulk -6 21 275 1110 0.56 3.83
E-10 PlusICE Eutectic Bulk -10 14 286 1140 0.56 3.33
E-11 PlusICE Eutectic Bulk -11.6 11 301 1090 0.57 3.55
E-12 PlusICE Eutectic Bulk -12.3 10 250 1110 0.56 3.47
E-14 PlusICE Eutectic Bulk -14.8 5 243 1220 0.53 3.51
E-15 PlusICE Eutectic Bulk -15 5 303 1060 0.53 3.87
E-19 PlusICE Eutectic Bulk -18.7 -2 282 1125 0.58 3.29
E-21 PlusICE Eutectic Bulk -20.6 -5 263 1240 0.51 3.13
E-22 PlusICE Eutectic Bulk -22 -8 234 1180 0.57 3.34
E-26 PlusICE Eutectic Bulk -26 -15 260 1250 0.58 3.67
E-29 PlusICE Eutectic Bulk -29 -20 222 1420 0.64 3.69
E-32 PlusICE Eutectic Bulk -32 -26 243 1290 0.56 2.95
E-34 PlusICE Eutectic Bulk -33.6 -28 240 1205 0.54 3.05
E-37 PlusICE Eutectic Bulk -36.5 -34 213 1500 0.54 3.15
E-50 PlusICE Eutectic Bulk -49.8 -58 218 1325 0.56 3.28
E-75 PlusICE Eutectic Bulk -75 -103 102 902 0.17 2.43
E-78 PlusICE Eutectic Bulk -78 -108 115 880 0.14 1.96
E-90 PlusICE Eutectic Bulk -90 -130 90 786 0.14 2.56
E-114 PlusICE Eutectic Bulk -114 -173 107 782 0.17 2.39
PCM-HS26N SAVENRG [87] Inorganic Bulk -26 -15 205 1200
PCM-HS23N SAVENRG Inorganic Bulk -23 -9 200 1180
PCM-HS10N SAVENRG Inorganic Bulk -10 14 220 1100
PCM-HS07N SAVENRG Inorganic Bulk -7 19 230 1120
PCM-HS01P SAVENRG Inorganic Bulk 0 32 290 1010
PCM-OM05P SAVENRG Organic Bulk 5 41 198 770
PCM-0M06P SAVENRG Organic Bulk 5.5 42 260 735
PCM-0M08P SAVENRG Organic Bulk 8 46 190 1050
PCM-0M11P SAVENRG Organic Bulk 11 52 260 1060
PCM-0M21P SAVENRG Organic Bulk 21 70 120 1050
PCM-H22P SAVENRG Inorganic Bulk 22 72 185 1540
PCM-HS24P SAVENRG Inorganic Bulk 24 75 185 1540
PCM-HS29P SAVENRG Inorganic Bulk 29 84 190 1550
PCM-OM32P SAVENRG Organic Bulk 32 90 235 870
PCM-OM35P SAVENRG Organic Bulk 35 95 197 870
PCM-HS34P SAVENRG Inorganic Bulk 34 93 150 1850
PCM-OM37P SAVENRG Organic Bulk 37 99 218 880
PCM-OM46P SAVENRG Organic Bulk 46 115 245 860
PCM-OM48P SAVENRG Organic Bulk 48 118 255 980
PCM-OM53P SAVENRG Organic Bulk 53 127 192 860
PCM-OM65P SAVENRG Organic Bulk 65 149 210 840
PCM-HS89P SAVENRG Inorganic Bulk 89 192 180 1540
MPCM -30 Microtek [88] Organic Micro-encapsulated -30 -22 145
MPCM -30D Microtek Organic Micro-encapsulated -30 -22 145
MPCM -10 Microtek Organic Micro-encapsulated -9.5 15 155
MPCM -10D Microtek Organic Micro-encapsulated -9.5 15 155
MPCM 6 Microtek Organic Micro-encapsulated 6 43 162
MPCM 6D Microtek Organic Micro-encapsulated 6 43 162
MPCM 18 Microtek Organic Micro-encapsulated 18 64 168
MPCM 18D Microtek Organic Micro-encapsulated 18 64 168
MPCM 28 Microtek Organic Micro-encapsulated 28 82 187.5
MPCM 28D Microtek Organic Micro-encapsulated 28 82 187.5
MPCM28D-IR Microtek Organic Micro-encapsulated 56 133 170
MPCM 37 Microtek Organic Micro-encapsulated 37 99 195
MPCM 37D Microtek Organic Micro-encapsulated 37 99 195
MPCM 43D Microtek Organic Micro-encapsulated 43 109 195
MPCM 56D Microtek Organic Micro-encapsulated 56 133 170
Latest 29 T TEAP Inorganic Bulk 28 82 175 1490 1 2
Latest 25 T TEAP Inorganic Bulk 24 75 175 1490 1 2
Latest 20 T TEAP Inorganic Bulk 19 66 175 1490 1 2
Latest 18 T TEAP Inorganic Bulk 17 63 175 1490 1 2
CrodaTherm™ 5 Croda International Plc [89] Organic Bulk 5 41 191
CrodaTherm™ 6.5 Croda International Plc Organic Bulk 6.8 44 184
CrodaTherm™ 15 Croda International Plc Organic Bulk 15 59 177
CrodaTherm™ 21 Croda International Plc Organic Bulk 21 70 176
CrodaTherm™ 29 Croda International Plc Organic Bulk 29 84 207
CrodaTherm™ 53 Croda International Plc Organic Bulk 53 127 226

The above dataset is also available as an Excel spreadsheet from UCLA Engineering

Technology, development and encapsulation

The most commonly used PCMs are salt hydrates, fatty acids and esters, and various paraffins (such as octadecane). Recently also ionic liquids were investigated as novel PCMs.

As most of the organic solutions are water-free, they can be exposed to air, but all salt based PCM solutions must be encapsulated to prevent water evaporation or uptake. Both types offer certain advantages and disadvantages and if they are correctly applied some of the disadvantages becomes an advantage for certain applications.

They have been used since the late 19th century as a medium for the thermal storage applications. They have been used in such diverse applications as refrigerated transportation[90] for rail[91] and road applications[92] and their physical properties are, therefore, well known.

Unlike the ice storage system, however, the PCM systems can be used with any conventional water chiller both for a new or alternatively retrofit application. The positive temperature phase change allows centrifugal and absorption chillers as well as the conventional reciprocating and screw chiller systems or even lower ambient conditions utilizing a cooling tower or dry cooler for charging the TES system.

The temperature range offered by the PCM technology provides a new horizon for the building services and refrigeration engineers regarding medium and high temperature energy storage applications. The scope of this thermal energy application is wide ranging of solar heating, hot water, heating rejection, i.e. cooling tower and dry cooler circuitry thermal energy storage applications.

Since PCMs transform between solid–liquid in thermal cycling, encapsulation[93] naturally become the obvious storage choice.

  • Encapsulation of PCMs
    • Macro-encapsulation: Early development of macro-encapsulation with large volume containment failed due to the poor thermal conductivity of most PCMs. PCMs tend to solidify at the edges of the containers preventing effective heat transfer.
    • Micro-encapsulation: Micro-encapsulation on the other hand showed no such problem. It allows the PCMs to be incorporated into construction materials, such as concrete, easily and economically. Micro-encapsulated PCMs also provide a portable heat storage system. By coating a microscopic sized PCM with a protective coating, the particles can be suspended within a continuous phase such as water. This system can be considered a phase change slurry (PCS).
    • Molecular-encapsulation is another technology, developed by Dupont de Nemours that allows a very high concentration of PCM within a polymer compound. It allows storage capacity up to 515 kJ/m2 for a 5 mm board (103 MJ/m3). Molecular-encapsulation allows drilling and cutting through the material without any PCM leakage.

As phase change materials perform best in small containers, therefore they are usually divided in cells. The cells are shallow to reduce static head – based on the principle of shallow container geometry. The packaging material should conduct heat well; and it should be durable enough to withstand frequent changes in the storage material's volume as phase changes occur. It should also restrict the passage of water through the walls, so the materials will not dry out (or water-out, if the material is hygroscopic). Packaging must also resist leakage and corrosion. Common packaging materials showing chemical compatibility with room temperature PCMs include stainless steel, polypropylene and polyolefin.

Thermal composites

Thermal-composites is a term given to combinations of phase change materials (PCMs) and other (usually solid) structures. A simple example is a copper-mesh immersed in a paraffin-wax. The copper-mesh within parraffin-wax can be considered a composite material, dubbed a thermal-composite. Such hybrid materials are created to achieve specific overall or bulk properties.

Thermal conductivity is a common property which is targeted for maximisation by creating thermal composites. In this case the basic idea is to increase thermal conductivity by adding a highly conducting solid (such as the copper-mesh) into the relatively low conducting PCM thus increasing overall or bulk (thermal) conductivity. If the PCM is required to flow, the solid must be porous, such as a mesh.

Solid composites such as fibre-glass or kevlar-pre-preg for the aerospace industry usually refer to a fibre (the kevlar or the glass) and a matrix (the glue which solidifies to hold fibres and provide compressive strength). A thermal composite is not so clearly defined, but could similarly refer to a matrix (solid) and the PCM which is of course usually liquid and/or solid depending on conditions. They are also meant to discover minor elements in the earth.

Applications

Phase-change material being employed in the treatment of neonates with birth asphyxia[94][95]

Applications[1][96] of phase change materials include, but are not limited to:

  • Thermal energy storage
  • Solar cooking
  • Cold Energy Battery
  • Conditioning of buildings, such as 'ice-storage'
  • Cooling of heat and electrical engines
  • Cooling: food, beverages, coffee, wine, milk products, green houses
  • Medical applications: transportation of blood, operating tables, hot-cold therapies, treatment of birth asphyxia[94]
  • Human body cooling under bulky clothing or costumes.
  • Waste heat recovery
  • Off-peak power utilization: Heating hot water and Cooling
  • Heat pump systems
  • Passive storage in bioclimatic building/architecture (HDPE, paraffin)
  • Smoothing exothermic temperature peaks in chemical reactions
  • Solar power plants
  • Spacecraft thermal systems
  • Thermal comfort in vehicles
  • Thermal protection of electronic devices
  • Thermal protection of food: transport, hotel trade, ice-cream, etc.
  • Textiles used in clothing
  • Computer cooling
  • Turbine Inlet Chilling with thermal energy storage
  • Telecom shelters in tropical regions. They protect the high-value equipment in the shelter by keeping the indoor air temperature below the maximum permissible by absorbing heat generated by power-hungry equipment such as a Base Station Subsystem. In case of a power failure to conventional cooling systems, PCMs minimize use of diesel generators, and this can translate into enormous savings across thousands of telecom sites in tropics.

Fire and safety issues

Some phase change materials are suspended in water, and are relatively nontoxic. Others are hydrocarbons or other flammable materials, or are toxic. As such, PCMs must be selected and applied very carefully, in accordance with fire and building codes and sound engineering practices. Because of the increased fire risk, flamespread, smoke, potential for explosion when held in containers, and liability, it may be wise not to use flammable PCMs within residential or other regularly occupied buildings. Phase change materials are also being used in thermal regulation of electronics.

See also

References

  1. ^ a b Kenisarin, M; Mahkamov, K (2007). "Solar energy storage using phase change materials". Renewable and Sustainable Energy Reviews. 11 (9): 1913–1965. doi:10.1016/j.rser.2006.05.005.
  2. ^ Sharma, Atul; Tyagi, V.V.; Chen, C.R.; Buddhi, D. (2009). "Review on thermal energy storage with phase change materials and applications". Renewable and Sustainable Energy Reviews. 13 (2): 318–345. doi:10.1016/j.rser.2007.10.005.
  3. ^ "Heat storage systems" (PDF) by Mary Anne White, brings a list of advantages and disadvantages of Paraffin heat storage. A more complete list can be found in AccessScience website from McGraw-Hill, DOI 10.1036/1097-8542.YB020415, last modified: March 25, 2002 based on 'Latent heat storage in concrete II, Solar Energy Materials, Hawes DW, Banu D, Feldman D, 1990, 21, pp.61–80.
  4. ^ Floros, Michael C.; Kaller, Kayden L. C.; Poopalam, Kosheela D.; Narine, Suresh S. (2016-12-01). "Lipid derived diamide phase change materials for high temperature thermal energy storage". Solar Energy. 139: 23–28. doi:10.1016/j.solener.2016.09.032.
  5. ^ Agyenim, Francis; Eames, Philip; Smyth, Mervyn (2011-01-01). "Experimental study on the melting and solidification behaviour of a medium temperature phase change storage material (Erythritol) system augmented with fins to power a LiBr/H2O absorption cooling system". Renewable Energy. 36 (1): 108–117. doi:10.1016/j.renene.2010.06.005.
  6. ^ See above: 'Heat Storage Systems' (Mary Anne White), page 2
  7. ^ "Infinite R™ | Phase Change Materials | Thermal Storage | Insolcorp, Inc – Phase Change Materials for Buildings & Environment". Infinite R™ | Phase Change Materials | Thermal Storage | Insolcorp, Inc. Retrieved 2017-03-01.
  8. ^ Pasupathy, A; Velraj, R; Seeniraj, R (2008). "Phase change material-based building architecture for thermal management in residential and commercial establishments". Renewable and Sustainable Energy Reviews. 12: 39–64. doi:10.1016/j.rser.2006.05.010.
  9. ^ HyperPhysics, most from Young, Hugh D., University Physics, 7th Ed., Addison Wesley, 1992. Table 15-5. (most data should be at 293 K (20 °C; 68 °F))
  10. ^ Ice – Thermal Properties. Engineeringtoolbox.com. Retrieved on 2011-06-05.
  11. ^ AAP (April 21, 2009). "Melburnians face 60pc water cost rise - MELBURNIANS face paying up to 60 per cent more for water and sewerage under proposals announced today by the state's economic regulator". The Australian. Retrieved 2010-02-24.
  12. ^ a b "Sodium Sulfate-Sodium Sulfate Manufacturers, Suppliers and Exporters on Alibaba.comSulphate".
  13. ^ a b Sarı, A (2002). "Thermal and heat transfer characteristics in a latent heat storage system using lauric acid". Energy Conversion and Management. 43 (18): 2493–2507. doi:10.1016/S0196-8904(01)00187-X.
  14. ^ a b H. Kakuichi et al., IEA annex 10 (1999)
  15. ^ Beare-Rogers, J.; Dieffenbacher, A.; Holm, J.V. (2001). "Lexicon of lipid nutrition (IUPAC Technical Report)". Pure and Applied Chemistry. 73 (4): 685–744. doi:10.1351/pac200173040685.
  16. ^ "lauric acid Q/MHD002-2006 lauric acid CN;SHN products". Alibaba.com. Retrieved 2010-02-24.
  17. ^ "Fatty Acids – Fractioned (Asia Pacific) Price Report – Chemical pricing information". ICIS Pricing. Retrieved 2010-03-10.
  18. ^ a b Nagano, K (2003). "Thermal characteristics of manganese (II) nitrate hexahydrate as a phase change material for cooling systems". Applied Thermal Engineering. 23 (2): 229–241. doi:10.1016/S1359-4311(02)00161-8.
  19. ^ a b Yinping, Zhang; Yi, Jiang; Yi, Jiang (1999). "A simple method, the -history method, of determining the heat of fusion, specific heat and thermal conductivity of phase-change materials". Measurement Science and Technology. 10 (3): 201–205. Bibcode:1999MeScT..10..201Y. doi:10.1088/0957-0233/10/3/015.
  20. ^ Kalapathy, Uruthira; Proctor, Andrew; Shultz, John (2002-12-10). "Silicate Thermal Insulation Material from Rice Hull Ash". Industrial & Engineering Chemistry Research. 42 (1): 46–49. doi:10.1021/ie0203227.
  21. ^ Sodium Silicate (Water Glass). Sheffield-pottery.com. Retrieved on 2011-06-05.
  22. ^ Hukseflux Thermal Sensors. Hukseflux.com. Retrieved on 2011-06-05.
  23. ^ Aluminium. Goodefellow. Web.archive.org (2008-11-13). Retrieved on 2011-06-05.
  24. ^ "Aluminum Prices, London Metal Exchange (LME) Aluminum Alloy Prices, COMEX and Shanghai Aluminum Prices". 23 February 2010. Retrieved 2010-02-24.
  25. ^ Copper. Goodfellow. Web.archive.org (2008-11-16). Retrieved on 2011-06-05.
  26. ^ a b c d e "Metal Prices and News". 23 February 2010. Retrieved 2010-02-24.
  27. ^ Gold. Goodfellow. Web.archive.org (2008-11-15). Retrieved on 2011-06-05.
  28. ^ Iron. Goodfellow. Web.archive.org (2008-11-18). Retrieved on 2011-06-05.
  29. ^ "Iron Page". 7 December 2007. Retrieved 2010-02-24.
  30. ^ Lead. Goodfellow. Web.archive.org (2008-11-18). Retrieved on 2011-06-05.
  31. ^ Lithium. Goodfellow. Web.archive.org (2008-11-18). Retrieved on 2011-06-05.
  32. ^ "Historical Price Query". August 14, 2009. Retrieved 2010-02-24.
  33. ^ Silver. Goodfellow. Web.archive.org (2008-11-17). Retrieved on 2011-06-05.
  34. ^ Titanium. Goodfellow. Web.archive.org (2008-11-15). Retrieved on 2011-06-05.
  35. ^ "Titanium Page". 28 December 2007. Retrieved 2010-02-24.
  36. ^ Zinc. Goodfellow. Web.archive.org (2008-11-18). Retrieved on 2011-06-05.
  37. ^ a b c d e f g h i j k l m n o Tamme, Rainer (February 20, 2003). "Phase Change - Storage Systems" (PDF).
  38. ^ a b c d e f g h i j k l m n o p q r s t u v w x y z aa ab ac ad ae af ag ah ai aj ak al am an ao ap aq ar as at au av aw ax ay az ba bb bc bd be bf bg bh bi bj bk bl bm bn bo bp bq br bs bt bu bv bw bx by bz ca cb cc cd ce cf cg ch ci cj ck cl "Review on thermal energy storage with phase change materials and applications". Renewable and Sustainable Energy Reviews. 13: 318–345. doi:10.1016/j.rser.2007.10.005.
  39. ^ a b c d e "Infinite R™ | Phase Change Materials | Thermal Storage | Insolcorp, Inc – Phase Change Materials for Buildings & Environment". Retrieved 2016-08-31.
  40. ^ "Pluss".
  41. ^ "TECHNICAL DATA SHEET OF HS 33N" (PDF).
  42. ^ "Pluss".
  43. ^ "TECHNICAL DATA SHEET – savE HS 26N" (PDF).
  44. ^ "TECHNICAL DATA SHEET OF savE HS23N" (PDF).
  45. ^ http://pluss.co.in/downloads/TDS/Doc%20318%20TDS_HS%2018N.pdf. {{cite web}}: Missing or empty |title= (help)
  46. ^ "TECHNICAL DATA SHEET OF savE HS15N" (PDF).
  47. ^ http://pluss.co.in/downloads/TDS/Doc404%20TDS_HS10N.pdf. {{cite web}}: Missing or empty |title= (help)
  48. ^ "TECHNICAL DATA SHEET – savE HS 7N" (PDF).
  49. ^ http://pluss.co.in/downloads/TDS/Doc%20431_TDS%20HS%2001.pdf. {{cite web}}: Missing or empty |title= (help)
  50. ^ "TECHNICAL DATA SHEET – savE OM 03" (PDF).
  51. ^ http://pluss.co.in/downloads/TDS/Doc%20471_TDS%20FS03.pdf. {{cite web}}: Missing or empty |title= (help)
  52. ^ "TECHNICAL DATA SHEET – savE OM 05" (PDF).
  53. ^ http://pluss.co.in/downloads/TDS/Doc%20473_TDS%20FS05.pdf. {{cite web}}: Missing or empty |title= (help)
  54. ^ "TECHNICAL DATA SHEET – savE OM 08" (PDF).
  55. ^ "TECHNICAL DATA SHEET – savE OM 11" (PDF).
  56. ^ "TECHNICAL DATA SHEET – savE OM 21" (PDF).
  57. ^ http://pluss.co.in/downloads/TDS/Doc%20353%20TDS_FS21.pdf. {{cite web}}: Missing or empty |title= (help)
  58. ^ "TECHNICAL DATA SHEET – savE HS 21" (PDF).
  59. ^ "TECHNICAL DATA SHEET – savE HS 22" (PDF).
  60. ^ "TECHNICAL DATA SHEET – savE HS 24" (PDF).
  61. ^ "TECHNICAL DATA SHEET – savE HS 29" (PDF).
  62. ^ http://pluss.co.in/downloads/TDS/Doc%20457%20TDS_OM%2029.pdf. {{cite web}}: Missing or empty |title= (help)
  63. ^ http://pluss.co.in/downloads/TDS/Doc%20456%20TDS_FS29.pdf. {{cite web}}: Missing or empty |title= (help)
  64. ^ http://pluss.co.in/downloads/TDS/Doc%20470_TDS%20OM30.pdf. {{cite web}}: Missing or empty |title= (help)
  65. ^ http://pluss.co.in/downloads/TDS/Doc%20469%20TDS_FS30.pdf. {{cite web}}: Missing or empty |title= (help)
  66. ^ "TECHNICAL DATA SHEET – savE OM 32" (PDF).
  67. ^ "TECHNICAL DATA SHEET – savE HS 34" (PDF).
  68. ^ "TECHNICAL DATA SHEET – savE OM 35a" (PDF).
  69. ^ http://pluss.co.in/technical-datasheets/Doc%20385%20TDS_OM37.pdf. {{cite web}}: Missing or empty |title= (help)
  70. ^ http://pluss.co.in/technical-datasheets/Doc%20383%20TDS_OM46.pdf. {{cite web}}: Missing or empty |title= (help)
  71. ^ http://pluss.co.in/technical-datasheets/Doc%20395_TDS%20OM48.pdf. {{cite web}}: Missing or empty |title= (help)
  72. ^ http://pluss.co.in/technical-datasheets/Doc%20445_TDS%20OM%2050.pdf. {{cite web}}: Missing or empty |title= (help)
  73. ^ http://pluss.co.in/technical-datasheets/Doc%20418%20TDS_OM55.pdf. {{cite web}}: Missing or empty |title= (help)
  74. ^ http://pluss.co.in/technical-datasheets/Doc%20426_TDS%20OM65.pdf. {{cite web}}: Missing or empty |title= (help)
  75. ^ http://pluss.co.in/technical-datasheets/Doc%20419_TDS%20FSM65.pdf. {{cite web}}: Missing or empty |title= (help)
  76. ^ http://pluss.co.in/technical-datasheets/Doc307-TDS-HS-89.pdf. {{cite web}}: Missing or empty |title= (help)
  77. ^ PureTemp. "PureTemp -37 technical data sheet".
  78. ^ PureTemp. "PureTemp -21 technical data sheet".
  79. ^ "Honeywell, Inc".
  80. ^ "Rubitherm GmbH".
  81. ^ "Climator - Home".
  82. ^ "Mitsubishi Chemical Corporation".
  83. ^ "CRISTOPIA Energy Systems".
  84. ^ "PCM Phase Change Material Materials Manufacturers".
  85. ^ "Phase Change Materials - BASF Dispersions & Pigments".
  86. ^ "Phase Change Materials: Thermal Management Solutions".
  87. ^ "Phase Change Materials (PCM) - Macro-encapsulated PCM manufacturing & supply".
  88. ^ "Microtek Laboratories - Microencapsulation Technology".
  89. ^ Croda International Plc. "Croda Phase Change Materials :: Products - Products".
  90. ^ Frederik Tudor the Ice King on ice transport during the 19th century
  91. ^ Richard Trevithick's steam locomotive ran in 1804
  92. ^ Amédée Bollée created steam cars beginning at 1873
  93. ^ Tyagi, Vineet Veer; Buddhi, D. (2007). "PCM thermal storage in buildings: A state of art". Renewable and Sustainable Energy Reviews. 11 (6): 1146–1166. doi:10.1016/j.rser.2005.10.002.
  94. ^ a b "How two low-cost, made-in-India innovations MiraCradle & Embrace Nest are helping save the lives of newborns". timesofindia-economictimes.
  95. ^ "MiraCradle™ - Neonate Cooler". {{cite web}}: C1 control character in |title= at position 11 (help)
  96. ^ Omer, A (2008). "Renewable building energy systems and passive human comfort solutions". Renewable and Sustainable Energy Reviews. 12 (6): 1562–1587. doi:10.1016/j.rser.2006.07.010.

PHASE CHANGE MATERIAL (PCM) BASED ENERGY STORAGE MATERIALS AND GLOBAL APPLICATION EXAMPLES Zafer URE M.Sc., C.Eng. MASHRAE HVAC Applications

Phase Change Material Based Passive Cooling Systems Design Principal and Global Application Examples Zafer URE M.Sc., C.Eng. MASHRAE Passive Cooling Application

Further reading