Jump to content

Deaerator

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Pooja Suhag (talk | contribs) at 13:07, 18 July 2023. The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

A deaerator is a device that removes oxygen and other dissolved gases from liquids and pumpable compounds. Deaerators are considered Water treatment equipment.

History

Manufacturing of deaerators started in the 1800s. Before 1867, deaerators were used as part of the ice manufacturing purification process. [1] Before 1881, feed water heaters were used for marine applications. [2]

Two sister ships Olympic and Titanic (1912) had contact feed heaters on board. [3] In 1934 the US Navy purchased an atomizing deaerator. [4] During the 1920s the feedwater headers and deaerators designs improved. [5] [6] [7] Deaerators continue to be used today for many applications.

Earlier patents

In 1899, George M Kleucker received a patent for an improved method of deaerating water. [8]

1921 through 1933, George Gibson, Percy Lyon, and Victor Rohlin of Cochrane received deaerator / degasification patents for bubbling steam through liquid.[9][10][11]

1926 Brown Stanley received a patent for reducing oxygen and nitrogen gases (deaeration).[12]

1937 Samuel B Applebaum of Permutit received a water deaerator and purifier patent.[13][14]

Manufacturing pioneers

Stickle, Cochrane, and Permutit are three of the oldest Deaerator manufacturers in the USA.[15] [16] In 1929, a court case between Elliott Company (no longer in business) and H.S.B.W. Cochrane Corporation allowed both businesses to continue manufacturing deaerators.[17]

In 1909 Weir was manufacturing contact feed heaters (for de-aeratoring) in Europe.[18][19][20]

By 1937 Permutit was manufacturing deaerators[21][22] In 1939, manufacturers Cochrane, Darby, Elliott, Groeschel, Stearns-Rogers, Worthington, and others were competing against each other for business.[23] In 1949 Chicago Heater was formed and became a leading deaerator manufacturer.[24] In 1954, manufacturers Allis-Chalmers, Chicago Heater, Cochrane, Elliott, Graver, Swartwout, Worthington, and others were in business.[25]

Type Industries

Deaerators are used in many industries such as Co-generation Plants, Hospital Boiler Rooms, Larger Laundry Facilities, Marine, Oil Fields (such as steam injection), Oil refinery, Off-Shore Platforms, Paper mills, Power Plant, Prison Boiler Rooms, Steel mills, and many other industries.

Types

  • The thermal deaerators [26][27][28]
    • The spray & tray-type (also called the cascade-type) includes a vertical or horizontal domed deaeration with a integral storage section, or as a separate section mounted on top of a horizontal cylindrical vessel which serves as the deaerated boiler feedwater storage tank.
    • The spray-type consists only of a horizontal (or vertical) cylindrical vessel which serves as both the deaeration section, and a storage tank for boiler feedwater.
  • The vacuum deaerators
    • Dynamic deaerator for medium to high viscous products
    • Static deaerator for low viscous products
  • The ultrasound deaerator for very viscous products

Thermal deaerators

Deaerator plant

Thermal deaerators are commonly used to remove dissolved gases in feedwater for steam-generating boilers. Dissolved oxygen in feedwater will cause serious corrosion damage in a boiler by attaching to the walls of metal piping and other equipment and forming oxides (like rust). Dissolved carbon dioxide combines with water to form carbonic acid that may cause further corrosion. Most deaerators are designed to remove oxygen down to levels of 7 ppb by weight or less, as well as essentially eliminating carbon dioxide.[29][30] The deaerators in the steam generating systems of most thermal power plants use low pressure steam obtained from an extraction point in their steam turbine system. However, the steam generators in many large industrial facilities such as petroleum refineries may use whatever low-pressure steam is available.

There are many different deaerators available from a number of manufacturers, and the actual construction details will vary from one manufacturer to another.

Figures 1 and 2 are representative schematic diagrams that depict each of the two major types of deaerators.

Spray and tray-type deaerator

Figure 1: A schematic diagram of a typical tray-type deaerator.

The typical spray & tray-type deaerator in Figure 1 has a vertical domed deaeration section mounted above a horizontal boiler feedwater storage vessel. Boiler feedwater enters the vertical deaeration section through spray valves above the perforated trays and then flows downward through the perforations. Low-pressure deaeration steam enters below the perforated trays and flows upward through the perforations. Combined action of spray valves & trays guarantees very high performance because of longer contact time between steam and water.[31][verification needed] Some designs use various types of packed beds, rather than perforated trays, to provide good contact and mixing between the steam and the boiler feed water.

The steam strips the dissolved gas from the boiler feedwater and exits via the vent valve at the top of the domed section. This vent valve should not be opened sufficiently the deaerator will not work properly, causing high oxygen content in the feed water going to the boilers. Should the boiler not have an oxygen-content analyzer, a high level in the boiler chlorides may indicate the vent valve not being far enough open. Some designs may include a vent condenser to trap and recover any water entrained in the vented gas. The vent line usually includes a valve and just enough steam is allowed to escape with the vented gases to provide a small visible telltale plume of steam.

The deaerated water flows down into the horizontal storage vessel from where it is pumped to the steam generating boiler system. Low-pressure heating steam, which enters the horizontal vessel through a Sparge Pipe in the bottom of the vessel, is provided to keep the stored boiler feedwater warm. Stainless steel material is recommended for the sparger pipe.[32] External insulation of the vessel is typically provided to minimize heat loss.

Spray-type deaerator

Figure 2: A schematic diagram of a typical spray-type deaerator.

As shown in Figure 2, the typical spray-type deaerator is a horizontal vessel which has a preheating section (E) and a deaeration section (F). The two sections are separated by a baffle (C). Low-pressure steam enters the vessel through a sparger in the bottom of the vessel.

The boiler feedwater is sprayed into section (E) where it is preheated by the rising steam from the sparger. The purpose of the feedwater spray nozzle (A) and the preheat section is to heat the boiler feedwater to its saturation temperature to facilitate stripping out the dissolved gases in the following deaeration section.

The preheated feedwater then flows into the deaeration section (F), where it is deaerated by the steam rising from the sparger system. The gases stripped out of the water exit via the vent at the top of the vessel. Again, some designs may include a vent condenser to trap and recover any water entrained in the vented gas. Also again, the vent line usually includes a valve and just enough steam is allowed to escape with the vented gases to provide a small and visible telltale plume of steam.

The deaerated boiler feedwater is pumped from the bottom of the vessel to the steam generating boiler system.

Silencers (optional) have been used for reducing venting noise levels in the Deaerator equipment industry.

Vacuum deaerator

Deaerators are also used to remove dissolved gases from products such as food, personal care products, cosmetic products, chemicals, and pharmaceuticals to increase the dosing accuracy in the filling process, to increase product shelf stability, to prevent oxidative effects (e.g. discolouration, changes of smell or taste, rancidity), to alter pH, and to reduce packaging volume. Vacuum deaerators are also used in the petrochemical field. [33]

In 1921 a tank with vacuum pump for removing gases was used in Pittsburgh.[34] In 1934 and 1940 a tank with vacuum pump for removing gases were used in Indiana.[35] [36]

Vacuum deaerators can be rubber lined on the inside to protect the steel heads and shell from corrosion.[37]

Dynamic deaerator

As shown in Figure 3, the product is distributed as a thin layer on a high speed spinning disc [3] via special feed system [1]. The centrifugal force slings it through a perforated screen onto the inner wall of the vessel, which is under vacuum . Air (gas) pockets are released in the process and are drawn off by the vacuum [4]. A discharge pump [2] carries the deaerated product to the next process in the production line. For high viscous products the rotating disc is replaced with static one.

Figure 3: A schematic diagram of rotating disc deaerator

Ultrasound deaerator

Sound waves using ultrasonic equipment can be used to assist deaerating water.[38][39]

Principles of operation

Oxygen and Nitrogen are two non-condensable gases that are removed by deaeration. Henry's law describes the relationship of dissolved gases and partial pressures. Thermal deaeration relies on the principle that the solubility of a gas in water decreases as the water temperature increases and approaches its boiling point. In the deaerator, water is heated up to close to its boiling point with a minimum pressure drop and minimum vent. Deaeration is done by spraying feedwater into a chamber to increase its surface area, and may involve flow over multiple layers of trays. This scrubbing (or stripping) steam is fed to the bottom of the deaeration section of the deaerator. When steam contacts the feedwater, it heats it up to its boiling point and dissolved gases are released from the feedwater and vented from the deaerator through the vent. The treated water falls into a storage tank below the deaerator.[40][29]


Oxygen scavenging

Oxygen scavenging chemicals are very often added to the deaerated boiler feedwater to remove any last traces of oxygen that were not removed by the deaerator. The type of chemical added depends on whether the location uses a volatile or non-volatile water treatment program.

Most lower pressure systems (lower than 650 psi (4,500 kPa)) use non-volatile treatment programs. The most commonly used oxygen scavenger for lower pressure systems is sodium sulfite (Na2SO3). It is very effective and rapidly reacts with traces of oxygen to form sodium sulfate (Na2SO4) which is non-scaling.

Most higher pressure systems (higher than 650 psi (4,500 kPa)) and all systems where certain highly alloyed materials are present are now using volatile programs, as many phosphate-based treatment programs are being phased out. Volatile programs are further broken down into oxidizing or reducing programs [(AVT(O) or AVT(R)] depending whether the environment requires an oxidizing or reducing environment to reduce the incidence of flow-accelerated corrosion. Flow-accelerated corrosion related failures have caused numerous accidents in which significant loss of property and life has occurred.[citation needed] Hydrazine (N2H4) is an oxygen scavenger commonly used in volatile treatment programs.

Other scavengers include carbohydrazide, diethylhydroxylamine, nitrilotriacetic acid, ethylenediaminetetraacetic acid, and hydroquinone.

Inspection and maintenance

NACE International (now known as Association for Materials Protection and Performance (AMPP)) and CIBO (Council of Industrial Boiler Owners) have several recommendations to increase the life of the deaerator unit. First, regular inspections (and testing) of the pressure vessel for cracking of welds, and repairing of any weld defects. Second, maintaining a proper water chemistry to reduce deaerator deterioration. Third, minimize temperature and pressure fluctuation. Fourth, internals and accessories should be inspected for proper operation. [41] [42][43] NACE had created a Corrosion Task Group in 1984 that studied causes of corrosion and provided recommendations;[44] NACE still provides recommendations to improve operations of the equipment.

Accessories

Deaerator accessories include vent valve, inlet pump(s), water inlet valve, overflow valve or trap, (safety) relief valve, vacuum breaker, steam pressure reducing valve, level instrument, temperature instrument, and discharge pump(s). Vacuum deaerator will also require Vacuum pump(s) and/or Vacuum ejector(s)/eductor(s).

Fabrication of deaerator

Welding of the steel pressure vessels during the manufacturing process sometimes requires Post weld heat treatment, XRAY, Dye Penetration, Ultrasonic, and other type non-destructive testing. ASME Boiler and Pressure Vessel Code, NACE International, and HEI (Heat Exchange Institute) have recommendations on the type of testing required. [45] Older fabrication techniques also used cast iron for the shell and heads.[46]

Insulation

Thermal insulation is sometimes required after fabrication or after installation at the project site. Insulation is used to reduce heat loses.[47]

See also

References

Citations

  1. ^ The Wichita Star, Wichita, KS, May 26, 1887. [1] Retrieved Apr 23, 2021
  2. ^ Iowa County Democrat, Mineral Point, WI, Mar 4, 1881. [2] Retrieved Apr 23, 2021
  3. ^ Encyclopedia Titanic by Stephen Carey. [3] Retrieved April 23, 2021
  4. ^ SAMCO, Aug 26, 2016. [4] Retrieved Apr 24, 2021
  5. ^ Montclair Times, Montclair, NJ, Dec 1, 1926. [5] Retrieved Apr 23, 2021
  6. ^ The News, Paterson, NJ, May 16, 1928. [6] Retrieved Apr 23, 2021
  7. ^ Vermont Tribune, Ludlow, Vermont, purifying feed water, Apr 13, 1900. [7] Retrieved April 23, 2021
  8. ^ US Patent August 1899. [8] Retrieved April 23, 2021
  9. ^ Patent, Google.[9] Retrieved Mar 18, 2023
  10. ^ Patent, Google.[10] Retrieved Mar 18, 2023
  11. ^ Google, Patent.[11] Retrieved Mar 18, 2023
  12. ^ Patent, Google.[12] Retrieved Mar 18, 2023
  13. ^ Intellingencer Journal, Feb 13, 1958.[13] Retrieved Mar 18, 2023
  14. ^ Patent Google.[14] Retrieved Mar 18, 2023
  15. ^ Stickle History, [15] Retrieved April 23, 2021
  16. ^ Handbook, Chapter 14 Degasification. http://ssu.ac.ir/cms/fileadmin/user_upload/Daneshkadaha/dbehdasht/markaz_tahghighat_olom_va_fanavarihaye_zist_mohiti/e_book/pasmand/water/58723_14.pdf] Retrieved April 23, 2021
  17. ^ Court Case, 1929. [16] Retrieved April 23, 2021
  18. ^ The Guardian, Nov 2, 1951.[17] Retrieved Mar 18, 2023
  19. ^ Daily Mail, Feb 9, 1925.[18] Retrieved Mar 18, 2023
  20. ^ The Perthshire Advertiser, Feb 27, 1909.[19] Retrieved Mar 18, 2023
  21. ^ Intellingencer Journal, Feb 13, 1958.[20] Retrieved Mar 18, 2023
  22. ^ Patent Google.[21] Retrieved Mar 18, 2023
  23. ^ The Alliance Times-Herald, Mar 31, 1939.[22] Retrieved Mar 18, 2023
  24. ^ Chicago Tribune, Jul 15, 1949.[23] Retrieved Mar 18, 2023
  25. ^ News-Record, Aug 2, 1954.[24] Retrieved Mar 18, 2023
  26. ^ Kent 1936.
  27. ^ Babcock & Wilcox Co. 2005.
  28. ^ Elliott, Chen & Swanekamp 1998, pp. 167-, Ch. 2.
  29. ^ a b "The Deaerating Principle". Sterling Deaerator Company.
  30. ^ "Deaerators". Stork. Archived from the original on 2018-09-01. Retrieved 2016-09-30.
  31. ^ Standards and Typical Specifications for Tray Type Deaerators (10th ed.). Heat Exchange Institute. November 2016.
  32. ^ Spirax Sarco, Jan 8, 2022. [25] retrieved Jan 8, 2022
  33. ^ OSTI abstract. [26] Retrieved April 23, 2021
  34. ^ Public Opinion, Chambersburg, PA, Feb 11, 1921. [27] Retrieved Jan 25, 2022
  35. ^ Palladium-Item, Richmond, Indiana, Sep 24, 1934. [28] Retrieved Jan 25, 2022
  36. ^ Union City Times-Gazette, Jul 23, 1940. [29] Retrieved Jan 25, 2022
  37. ^ Paterson Evening News, Paterson, NJ, Sep 12, 1956.[30] Retrieved Jun 4, 2023
  38. ^ STS Canada.[31] Retrieved Mar 18, 2023
  39. ^ Hielscher.[32] Retrieved Mar 18, 2023
  40. ^ "Deaerator working principle". Boilers Info.
  41. ^ AMPP, NACE RFP050-96, Standard Recommended Practice. [33] Retrieved April 22, 2021
  42. ^ The National Board of Boiler and Pressure Vessel Inspectors, April 1988. [34] Retrieved April 22, 2021
  43. ^ US Dept of Energy, CIBO paper dated Nov 1997. [35] Retrieved April 23, 2021
  44. ^ Proceedings of the American Power Conference paper, Otakar Jonas. [36] Retrieved Jun 3, 2022
  45. ^ Deaerator history. [37] Retrieved Apr 24, 2021
  46. ^ Vancouver Sun, Apr 14, 1962.[38] Retrieved Jun 4, 2023
  47. ^ US Dept of Energy, Deaerators in Industrial Steam Systems.[39] Retrieved Mar 18, 2023

Sources

Additional reading

Betz Handbook of Industrial Water Conditioning, Chapter 9 boiler feedwater deaeration. 8th Edition, copyright 1980, LOC 79-56368.

National Board "System Design, Specifications, Operation, and Inspection of Deaerators" April 1988. https://www.nationalboard.org/index.aspx?pageID=164&ID=180

NEA (National Environmental Agency) Paper, "Energy Best Practice Guide for Oil Refining, Petrochemical and Chemical Plants", June 2021. https://www.nea.gov.sg/docs/default-source/our-services/energy-efficiency/best-practice-guide-for-heating-systems.pdf

US Dept of Energy, Deaerators in Industrial Steam Systems. https://www.energy.gov/sites/prod/files/2014/05/f16/steam18_steam_systems.pdf