Jump to content

Transcritical cycle

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Woodlot (talk | contribs) at 19:15, 7 September 2021 (spelling). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

A transcritical cycle is a closed thermodynamic cycle where the working fluid goes through both subcritical and supercritical states. In particular, for power cycles the working fluid is kept in the liquid region during the compression phase and in vapour and/or supercritical conditions during the expansion phase. The ultrasupercritical steam Rankine cycle represents a widespread transcritical cycle in the electricity generation field from fossil fuels, where water is used as working fluid.[1] Other typical applications of transcritical cycles to the purpose of power generation are represented by organic Rankine cycles,[2] which are especially suitable to exploit low temperature heat sources, such as geothermal energy,[3] heat recovery applications[4] or waste to energy plants.[5] With respect to subcritical cycles, the transcritical cycle exploits by definition higher pressure ratios, an feature that ultimately yields higher efficiencies for the majority of the working fluids. Considering then also supercritical cycles as a valid alternative to the transcritical ones, the latter cycles are capable of achieving higher specific works due to the limited relative importance of the work of compression work.[6] This evidences the extreme potential of transcritical cycles to the purpose of producing the most power (measurable in terms of the cycle specific work) with the least expenditure (measurable in terms of spent energy to compress the working fluid).

While in single level supercritical cycles both pressure levels are above the critical pressure of the working fluid, in transcritical cycles one pressure level is above the critical pressure and the other is below. In the refrigeration field carbon dioxide, CO2, is increasingly considered of interest as refrigerant.[7][8][9][10]

Transcritical conditions of the working fluid

Phase diagram of a generic fluid
TQ diagram of heat introduction to a subcritical and transcritical cold source

In trascritical cycles, the pressure of the working fluid at the outlet of the pump is higher than the critical pressure, while the inlet conditions are close to the saturated liquid pressure at the given minimum temperature.

During the heating phase, which is typically considered an isobaric process, the working fluid overcomes the critical temperature, moving thus form the liquid to the supercritical phase without the occurrence of any evaporation process, a significant difference between subcritical and transcritical cycles.[11] Due to this significant difference in the heating phase, the heat injection into the cycle is significantly more efficient from a second law perspective, since the average temperature difference between the hot source and the working fluid is reduced.[12]

As a consequence, the maximum temperatures reached by the cold source can be higher at fixed hot source characteristics. Therefore, the expansion process can be accomplished exploiting higher pressure ratios, which yields higher power production. Modern ultrasupercritical Rankine cycles can reach maximum temperatures up to 620°C exploiting the optimized heat introduction process.[13]

Characterization of the power cycle

Ts diagrams of subcritical (yellow), transcritical (blue) and supercritical (red) power cycles
Plant layouts of transcritical power cycles (top left), supercritical power cycles (top right), subritical power cycles (bottom)

As in any power cycle, the most important indicator of its performance is the thermal efficiency. The thermal efficiency of a transcritical cycle is computed as:

where is the thermal input of the cycle, provided by either combustion or with an heat exchanger, and is the power produced by the cycle.

The power produced is considered comprehensive of the produced power during the expansion process of the working fluid and the one consumed during the compression step.

The typical conceptual configuration of a transcritical cycle employs a single heater,[14][15] thanks to the absence of drastic phase change from one state to another, being the pressure above the critical one. In subcritical cycles, instead, the heating process of the working fluid occurs in three different heat exchangers:[16] in economizers the working fluid is heated (while remaining in the liquid phase) up to a condition approaching the saturated liquid conditions. Evaporators accomplish fluid evaporation process (typically up to the saturated vapour conditions) and in superheaters the working fluid is heated form the saturated vapour conditions to a superheated vapor. Moreover, using Rankine cycles as bottoming cycles in the context of combined gas-steam cycles keeps the configuration of the former ones as always subcritical. Therefore, there will be multiple pressure levels and hence multiple evaporators, economizers and superheaters, which introduces a significant complication to the heat injection process in the cycle.[17]

Characterization of the compression process

Pump diagram
Compressor Stage GE J79

Along adiabatic and isentropic processes, such as those theoretically associated with pumping processes in transcritical cycles, the enthalpy difference across both a compression and an expansion is computed as:

Consequently, a working fluid with a lower specific volume (hence higher density) can inevitably be compressed spending a lower mechanical work than one with low density (more gas like).

In transcritical cycles, the very high maximum pressures and the liquid conditions along the whole compression phase ensure a higher density and a lower specific volume with respect to supercritical counterparts. Considering the different physical phases though which compression processes occur, transcritical and supercritical cycles employ pumps (for liquids) and compressors (for gases), respectively, during the compression step.

Characterization of the expansion process

Traditional classification of expansions with pure working fluids
TurbineBlades

In the expansion step of the working fluid in transcritical cycles, as in subcritical ones, the working fluid can be discharged either in wet or dry conditions.

Typical dry expansions are those involving organic or other unconventional working fluids, which are characterized by non-negligible molecular complexities and high molecular weights.

The expansion step occurs in turbines: depending on the application and on the nameplate power produced by the power plant, both axial turbines and radial turbines can be exploited during fluid expansion. Axial turbines favour lower rotational speed and higher power production, while radial turbines are suitable for limited powers produced and high rotational speed.

Organic cycles are appropriate choices for low enthalpy applications and are characterized by higher average densities across the expanders than those occurring in transcritical steam cycles: for this reason a low blade height is normally designed [18] and the volumetric flow rate is kept limited to relatively small values. On the other hand in large scale application scenarios the expander blades typically show heights that exceed one meter and that are exploited in the steam cycles. Here, in fact, the fluid density at the outlet of the last expansion stage is significantly low.

In general, the specific work of the cycle is expressed as:

Even though the specific work of any cycle is strongly dependent on the actual working fluid considered in the cycle, transcritical cycles are expected to exhibit higher specific works than the corresponding subcritical and supercritical counterparts (i.e., that exploit the same working fluid). For this reason, at fixed boundary conditions, power produced and working fluid, a lower mass flow rate is expected in transcritical cycles than in other configurations.

Applications in power cycles

Ultrasupercritical Rankine cycles

Simplified layout of a coal fired power plant

In the last decades, the thermal efficiency of Rankine cycles increased drastically, especially for large scale applications fueled by coal: for these power plants, the application of ultrasupercritical layouts was the main factor to achieve the goal, since the higher pressure ratio ensures higher cycle efficiencies.

The increment in thermal efficiency of power plants fueled by dirty fuels became crucial also in the reduction of the specific emissions of the plants, both in therms of greenhouse gas and for pollutant such as sulfur dioxide or NOx. In large scale applications, ultrasupercritical Rankine cycles employ up to 10 feedwater heaters, five on the high pressure side and five on the low pressure side, including the deaerator, helping in the increment of the temperature at the inlet of the boiler up to 300°C, allowing a significant regenerative air preheating, thus reducing the fuel consumption. Studies on the best performant configurations of supercritical rankine cycles (300 bar of maximum pressure, 600°C of maximum temperature and two reheats) show that such layouts can achieve a cycle efficiency higher than 50%, about 6% higher than subcritical configurations.[19]

Organic Rankine cycles

Internal view of Plug-and-Play Micro-ORC
Ts Diagram of subcritical and transcritical R134a cycles

Organic Rankine cycles are innovative power cycles which allow good performances for low enthalpy thermal sources[20] and ensure condensation above the atmosferic pressure, thus avoiding deaerators and large cross sectional area in the heat rejection units. Moreover, with respect to steam Rankine cycles, ORC have a higher flexibilty in handling low power sizes, allowing significant compactness. Typical applications of ORC cover: waste heat recovery plants, geothermal plants, biomass plants and waste to energy power plants.

Organic Rankine cycles use organic fluids (such as hydrocarbons, perfluorocarbons, chlorofluorocarbon, and many others) as working fluids.[21] Most of them have a critical temperature in the range of 100-200°C,[22] for this reason perfectly adaptable to transcritical cycles in low temperature applications.[23] Considering organic fluids, having a maximum pressure above the critical one can more than double the temperature difference across the turbine, with respect to the subcritical counterpart, and significantly increase both the cycle specific work and cycle efficiency.

Applications in refrigeration cycles

A refrigeration cycle, also known as heat pump, is a thermodynamic cycle that allows the removal of heat from a low temperature heat source and the rejection of heat into a high temperature heat source, thanks to mechanical power consumption.[24] Traditional refrigeration cycles are subcritical, with the high pressure side (where heat rejection occurs) below the critical pressure.[25]

Innovative transcritical refrigeration cycles, instead, should use a working fluid whose critical temperature is around the ambient temperature. For this reason, carbon dioxide is chosen due to its favourable critical conditions. In fact, the critical point of carbon dioxide is 31°C, reasonably in between the hot source and cold source of traditional refrigeration applications, thus suitable for a transcritical applications.

In transcritical refrigeration cycles the heat is dissipated through a gas cooler instead of a desuperheater and a condenser[26] like in subcritical cycles.This limits the plant components, plant complexity and costs of the power block.

The advantages of using carbon dioxide as working fluid, instead of traditional refrigerant fluids (like HFC of HFO), in refrigeration cycles is represented both by economic aspects and environmental ones. On one hand, the cost of carbon dioxide is two order of magnitude lower than the ones of the average refrigerant working fluid, on the other hand the environmental impact of carbon dioxide is very limited (with a GWP of 1 and an ODP of 0), the fluid is not toxic nor reactive. No other working fluids for refrigeration is able to reach the same environmental favourable characteristics of carbon dioxide.[27]

References

  1. ^ Tominaga (2017). Advances in Steam Turbines for Modern Power Plants. Elsevier. p. 41. ISBN 978-0-08-100314-5.
  2. ^ Yu, Chao; Xu, Jinliang; Sun, Yasong (September 2015). "Transcritical pressure Organic Rankine Cycle (ORC) analysis based on the integrated-average temperature difference in evaporators". Applied Thermal Engineering. 88: 2–13. doi:10.1016/j.applthermaleng.2014.11.031.
  3. ^ Hassani Mokarram, N.; Mosaffa, A.H. (June 2020). "Investigation of the thermoeconomic improvement of integrating enhanced geothermal single flash with transcritical organic Rankine cycle". Energy Conversion and Management. 213: 112831. doi:10.1016/j.enconman.2020.112831.
  4. ^ Lecompte, Steven; Ntavou, Erika; Tchanche, Bertrand; Kosmadakis, George; Pillai, Aditya; Manolakos, Dimitris; De Paepe, Michel (2019-06-25). "Review of Experimental Research on Supercritical and Transcritical Thermodynamic Cycles Designed for Heat Recovery Application". Applied Sciences. 9 (12): 2571. doi:10.3390/app9122571.{{cite journal}}: CS1 maint: unflagged free DOI (link)
  5. ^ Behzadi, Amirmohammad; Gholamian, Ehsan; Houshfar, Ehsan; Habibollahzade, Ali (October 2018). "Multi-objective optimization and exergoeconomic analysis of waste heat recovery from Tehran's waste-to-energy plant integrated with an ORC unit". Energy. 160: 1055–1068. doi:10.1016/j.energy.2018.07.074.
  6. ^ Oyewunmi, Oyeniyi A.; Ferré-Serres, Simó; Lecompte, Steven; van den Broek, Martijn; De Paepe, Michel; Markides, Christos N. (May 2017). "An Assessment of Subcritical and Trans-critical Organic Rankine Cycles for Waste-heat Recovery". Energy Procedia. 105: 1870–1876. doi:10.1016/j.egypro.2017.03.548.
  7. ^ Dai, Baomin; Liu, Shengchun; Li, Hailong; Sun, Zhili; Song, Mengjie; Yang, Qianru; Ma, Yitai (May 2018). "Energetic performance of transcritical CO2 refrigeration cycles with mechanical subcooling using zeotropic mixture as refrigerant". Energy. 150: 205–221. doi:10.1016/j.energy.2018.02.111.
  8. ^ Baheta, Aklilu Tesfamichael; Hassan, Suhaimi; Reduan, Allya Radzihan B.; Woldeyohannes, Abraham D. (2015). "Performance Investigation of Transcritical Carbon Dioxide Refrigeration Cycle". Procedia CIRP. 26: 482–485. doi:10.1016/j.procir.2015.02.084.
  9. ^ Lo Basso, Gianluigi; de Santoli, Livio; Paiolo, Romano; Losi, Claudio (February 2021). "The potential role of trans-critical CO2 heat pumps within a solar cooling system for building services: The hybridised system energy analysis by a dynamic simulation model". Renewable Energy. 164: 472–490. doi:10.1016/j.renene.2020.09.098.
  10. ^ Austin, Brian T.; Sumathy, K. (October 2011). "Transcritical carbon dioxide heat pump systems: A review". Renewable and Sustainable Energy Reviews. 15 (8): 4013–4029. doi:10.1016/j.rser.2011.07.021.
  11. ^ Chen, Y.; Lundqvist, P. (2011-01-01). The CO2 Transcritical Power Cycle for Low Grade Heat Recovery: Discussion on Temperature Profiles in System Heat Exchangers. ASME 2011 Power Conference, Volume 1. pp. 385–392. doi:10.1115/POWER2011-55075.
  12. ^ Macchi, Ennio (2016). Organic Rankine Cycle (ORC) Power Systems. Kent, UK: Elsevier Science. p. 73. ISBN 978-0-08-100510-1.
  13. ^ Phillips, Jeffrey (2016). "Advanced Ultrasupercritical Update: Rankine Cycles above 1200 deg F". doi:10.13140/RG.2.1.1544.9842. {{cite journal}}: Cite journal requires |journal= (help)
  14. ^ Lisheng, Pan; Bing, Li; Yuan, Yao; Weixiu, Shi; Xiaolin, Wei (February 2019). "Theoretical investigation on a novel CO2 transcritical power cycle using solar energy". Energy Procedia. 158: 5130–5137. doi:10.1016/j.egypro.2019.01.686.
  15. ^ Long, Henry A.; Wang, Ting; Thomas, Arian (2017-06-26). Evaluation of Using Supercritical Rankine Cycles in Integrated Coal Gasification Combined Cycles (IGCC). Volume 3: Coal, Biomass and Alternative Fuels; Cycle Innovations; Electric Power; Industrial and Cogeneration Applications; Organic Rankine Cycle Power Systems. pp. V003T03A015. doi:10.1115/GT2017-65246.
  16. ^ Ibrahim, Thamir k.; Mohammed, Mohammed Kamil; Awad, Omar I.; Rahman, M.M.; Najafi, G.; Basrawi, Firdaus; Abd Alla, Ahmed N.; Mamat, Rizalman (November 2017). "The optimum performance of the combined cycle power plant: A comprehensive review". Renewable and Sustainable Energy Reviews. 79: 459–474. doi:10.1016/j.rser.2017.05.060.
  17. ^ Tajik Mansouri, Mohammad; Ahmadi, Pouria; Ganjeh Kaviri, Abdolsaeid; Jaafar, Mohammad Nazri Mohd (June 2012). "Exergetic and economic evaluation of the effect of HRSG configurations on the performance of combined cycle power plants". Energy Conversion and Management. 58: 47–58. doi:10.1016/j.enconman.2011.12.020.
  18. ^ Kim, Jun-Seong; Kim, Do-Yeop (2020-04-24). "Preliminary Design and Off-Design Analysis of a Radial Outflow Turbine for Organic Rankine Cycles". Energies. 13 (8): 2118. doi:10.3390/en13082118.{{cite journal}}: CS1 maint: unflagged free DOI (link)
  19. ^ Salazar-Pereyra, Martín; Lugo-Leyte, Raúl; Bonilla-Blancas, Angélica Elizabeth; Lugo-Méndez, Helen Denise (2016-06-13). Thermodynamic Analysis of Supercritical and Subcritical Rankine Cycles. Volume 8: Microturbines, Turbochargers and Small Turbomachines; Steam Turbines. pp. V008T26A041. doi:10.1115/GT2016-57814.
  20. ^ Yadav, Kriti; Sircar, Anirbid (December 2019). "Selection of working fluid for low enthalpy heat source Organic Rankine Cycle in Dholera, Gujarat, India". Case Studies in Thermal Engineering. 16: 100553. doi:10.1016/j.csite.2019.100553.
  21. ^ Luo, Dong; Mahmoud, Ahmad; Cogswell, Frederick (June 2015). "Evaluation of Low-GWP fluids for power generation with Organic Rankine Cycle". Energy. 85: 481–488. doi:10.1016/j.energy.2015.03.109.
  22. ^ Quoilin, Sylvain; Broek, Martijn Van Den; Declaye, Sébastien; Dewallef, Pierre; Lemort, Vincent (June 2013). "Techno-economic survey of Organic Rankine Cycle (ORC) systems". Renewable and Sustainable Energy Reviews. 22: 168–186. doi:10.1016/j.rser.2013.01.028.
  23. ^ Bombarda, Paola. Comparison of Enhanced Organic Rankine Cycles for Geothermal Power Units (PDF). [Melbourne].
  24. ^ Yu, Shui (2018). "Introduction of Water Source Heat Pump System". Handbook of Energy Systems in Green Buildings: 1–48. doi:10.1007/978-3-662-49088-4_4-1.
  25. ^ Yan, Hongzhi; Wu, Di; Liang, Junyu; Hu, Bin; Wang, R.Z. (July 2021). "Selection and validation on low-GWP refrigerants for a water-source heat pump". Applied Thermal Engineering. 193: 116938. doi:10.1016/j.applthermaleng.2021.116938.
  26. ^ Sarkar, Jahar (2010). "Review on Cycle Modifications of Transcritical CO2 Refrigeration and Heat Pump Systems". Journal of Advanced Research in Mechanical Engineering. 1 (1): 22–29.
  27. ^ Sarkar, J.; Bhattacharyya, Souvik; Ram Gopal, M. (January 2007). "Natural refrigerant-based subcritical and transcritical cycles for high temperature heating". International Journal of Refrigeration. 30 (1): 3–10. doi:10.1016/j.ijrefrig.2006.03.008.