Jump to content

Sydney Harbour Tunnel

From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Davemody (talk | contribs) at 17:20, 31 August 2011 (Construction). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Sydney Harbour Tunnel
Sydney Harbour Tunnel, northbound
Overview
LocationPort Jackson
Coordinates33°51′09″S 151°12′43″E / 33.85260°S 151.21187°E / -33.85260; 151.21187
StatusActive
StartWarringah Freeway
EndCahill Expressway
Operation
ConstructedJanuary 1988 – August 1992
OwnerSydney Harbour Tunnel Company
OperatorSydney Harbour Tunnel Company
TrafficAutomotive
Vehicles per dayca 90,000 (2008)[1]
Technical
Length2.8km
No. of lanes4
Tunnel clearance9m[2]
Width10.5m[2]

The Sydney Harbour Tunnel is a twin-tube road tunnel in Sydney, Australia. The tunnel was completed and opened to traffic in August 1992 to provide a second vehicular crossing of Sydney Harbour to alleviate congestion on the Sydney Harbour Bridge.

The tunnel joins the Warringah Freeway at North Sydney, and the Cahill Expressway at the entrance to the Domain Tunnel. It has two lanes in each direction, and runs at an angle of approximately thirty degrees (North to South) to the Sydney Harbour Bridge, which has eight lanes, with a tidal flow operation. In 2008, the tunnel was carrying around 90,000 vehicles per day.[1][3]

Construction

The tunnel is made up of three sections: twin 900-metre land tunnels on the north shore, twin 400-metre land tunnels on the south shore and a 960-metre immersed tube (IMT) structure. The tunnel falls about 55 metres from the northern entrance and about 35 metres from the southern entrance to its deepest point, 25 metres below sea level.

The IMT structure consists of eight precast concrete units. The units were constructed over 100 kilometres away in a casting basin at Port Kembla and then towed to Sydney Harbour. A trench was dredged before the arrival of the IMTs and then the IMTs were lowered into the trench by a system of pontoons and control towers. After the IMTs were in place the trenches were backfilled and then a rock armour was placed over the top to protect the units against marine hazards, such as anchors or sinking vessels.

The land tunnels were constructed by a combination of driving and cut-and-cover techniques. The total construction cost of the project was A$554.25 million, and was designed to be strong enough to withstand the impact of earthquakes and sinking ships.

One of the northern end pylons of the Sydney Harbour Bridge was altered to allow for air exhaust from the tunnel to rise over the harbour. Bradfield Park on the northern side of the bridge also has hidden air intakes behind some conspicuously placed bushes.

Fresh air is drawn by an underground ventilation station on the north shore and is pumped to all sections of the tunnel through vented ducts. The air supply uses fourteen axial flow fans, each up to 2.5 meters in diameter. The exhaust uses sixteen (eight in each northern pylon tower) fans that draw exhaust air through two underground ducts from the tunnel ventillation station and transfer the air to the top of the pylon. They can expel it at up to 1500 cu M/sec - equivalent to changing all the air in the tunnel every two minutes[4]with the capability of running in reverse in an emergency and all fans are rated for smoke extraction. Each of the fans has duty of 53 to 103 m3/sec. The testing of the fans was one of the most comprehensive ever, covering flowrate and pressure, power measurements, sound levels, bearing vibration, x-raying of all impeller components, high temperature tests at 200 °C for 2 hours, impeoller strain, and 24 hour run tests for reversals. [5]

The tunnel was opened to the public to walk through from North Sydney (Falcon Street) to South Sydney (The Domain) on 30 August 1992. The proceeds of the tickets sold for this event were donated to the Royal Institute for Deaf and Blind Children. The tunnel opened to traffic on 31 August 1992.[6]

Operator

The Harbour Tunnel is a partnership between the Government of New South Wales and private investors by tender. Transfield Pty Limited and Kumagai Gumi formed a 50/50 joint venture company which constructed the tunnel under contract; with an operating contract, including revenue collection and maintenance, from 1992 until 2023. As a result of the 1997 separation of assets of Transfield and the creation of the Tenix group, the ongoing thirty-year operating contract for management of the tunnel is split between Kumagai Gumi (50%), Transfield (25%) and Tenix (25%). At the conclusion of the operating contract in June 2023, the tunnel is to be handed back to the NSW Government.[1][7]

There was a lot of scepticism surrounding the appointment of Transfield to build the tunnel, after other projects including IMT tunnels, carried out by the group, developed structural problems resulting in leaks.[citation needed]

Tolling

In 2006, the New South Wales Government announced that all cash tolls on the Sydney Orbital Network will cease by 2010.[8] The Sydney Harbour Tunnel went fully electronic in July 2007 with both e-TAG and e-pass video tolling arrangements in use, similar to technologies used the Westlink M7, Cross City Tunnel and the Lane Cove Tunnel.[9] This measure has substantially eased the traffic jams heading towards the electronic gantries, and providing increased convenience and time savings. The Sydney Harbour Tunnel attracts a varying toll (that was introduced in 2009) of between A$2.50 and A$4.00, depending on the time of day.[10] The toll is levied on the southbound approach to the tunnel entrance.

Exits and interchanges

Southern entrance to the Sydney Harbour Tunnel, heading northbound
Sydney Harbour Tunnel
Northwestbound exits Distance to
Brisbane
(km)
Distance to
Sydney Airport
(km)
Southeastbound exits
End Sydney Harbour Tunnel
continues as Warringah Freeway
to Newcastle / Brisbane
932 15 Start Sydney Harbour Tunnel
from Warringah Freeway
PORT JACKSON CROSSING -- -- PORT JACKSON CROSSING
Start Sydney Harbour Tunnel
continues from Cahill Expressway
935 12 End Sydney Harbour Tunnel
continues as Cahill Expressway
to Wollongong / Canberra
Sydney (Kingsford Smith) Airport

See also

Notes

References

  1. ^ a b c Robins, Brian; Besser, Linton (11 December 2008). "Sydney Harbour tunnel a $1b black hole". The Sydney Morning Herald. Retrieved 1 February 2011.
  2. ^ a b Muhammad, Imran; Low, Nicholas (December 2006). Mega Projects in Transport and Development: Background in Australian Case Studies. Australasian Centre for the Governance and Management of Urban Transport. Accessed 3 July 2009.
  3. ^ Ralston, Nick (11 December 2008). "Harbour tunnel still good value: govt". The Sydney Morning Herald. Retrieved 1 February 2011.
  4. ^ Australian Telegraph Mirror Harbour Tunnel Souvenir, illustrating the novel approach taken, courtesy of The News Ltd, Sydney Australia republished in Fans and Ventilation-A Practical Guide - Bill Cory, pg 17
  5. ^ Fans and Ventilation-A Practical Guide - Bill Cory, pg 18
  6. ^ Sydney Harbour Tunnel. Roads and Traffic Authority. Accessed 3 July 2009.
  7. ^ McDonald, Hamish (12 March 2011). "Take a look north for the road ahead". The Sydney Morning Herald. Retrieved 3 August 2011.
  8. ^ Aston, Heath (25 April 2007). "Sydney toll network dumps coins". The Daily Telegraph. Australia. Retrieved 3 August 2011.
  9. ^ Aston, Heath (5 July 2007). "Drivers' gridlock on e-tags". The Daily Telegraph. Australia. Retrieved 3 August 2011.
  10. ^ Haynes, Rhys (19 July 2011). "Peak-hour tolls on the Harbour Bridge and Tunnel could be scrapped". The Daily Telegraph. Australia. Retrieved 3 August 2011.