Jump to content

Talk:Titanium alloys

Page contents not supported in other languages.
From Wikipedia, the free encyclopedia

This is an old revision of this page, as edited by Yellowy cake (talk | contribs) at 21:32, 6 August 2018. The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

WikiProject iconChemistry Start‑class Low‑importance
WikiProject iconThis article is within the scope of WikiProject Chemistry, a collaborative effort to improve the coverage of chemistry on Wikipedia. If you would like to participate, please visit the project page, where you can join the discussion and see a list of open tasks.
StartThis article has been rated as Start-class on Wikipedia's content assessment scale.
LowThis article has been rated as Low-importance on the project's importance scale.

Need to figure out how to fix reference and add external links. It's a bit messed up. Need to add this link as it's a great reference: http://www.tifab.com/subpages/tech_spec_grades.htm War (talk) 08:41, 17 February 2008 (UTC)[reply]


Idle curiosity here.....grade 38 would be best for a suit of armor, correct? —Preceding unsigned comment added by 99.242.210.65 (talk) 19:17, 17 April 2009 (UTC)[reply]

Alpha and beta phases

Alpha and beta are just names given to various lattice structures of the material by material scientists. See titanium#Physical for explanations. Wizard191 (talk) 15:26, 11 August 2009 (UTC)[reply]

ASTM B861 - 10 Standard Specification for Titanium and Titanium Alloy Seamless Pipe

From the abstract of ASTM B861 - 10 at http://www.astm.org/Standards/B861.htm:

This specification covers the requirements for 34 grades of titanium and titanium alloy seamless pipe intended for general corrosion resisting and elevated temperature service.

In other words, ASTM B861 - 10 covers only part of the many tungsten alloys used. Further, ASTM B861 - 10 does not include a Grade 6 for titanium, despite the fact that it appears in the article in the list of grades as if it does. Importantly, ASTM B861 - 10 does provide useful and important information about Grades 1 to 5 that the article glosses over completely.

Next, Ti6Al4V alloy contains cytotoxic vanadium. Currently, the article asserts:

Consequently, it is used extensively in aerospace, medical, marine, and chemical processing[7]

Contrary to the assertion in the article, however, reference #7, itself citing the Titanium Information Group, given in support of the Wikipedia assertion makes no mention of its use in the medical industry. This is what the text of the reference states:

This alpha-beta alloy is the workhorse alloy of the titanium industry. The alloy is fully heat treatable in section sizes up to 15mm and is used up to approximately 400°C (750°F). Since it is the most commonly used alloy – over 70% of all alloy grades melted are a sub-grade of Ti6Al4V, its uses span many aerospace airframe and engine component uses and also major non-aerospace applications in the marine, offshore and power generation industries in particular.

and

Applications

As mentioned previously, this alloy is the most popular of the titanium alloys. It is used for a range of applications in the aerospace, marine, power generation and offshore industries.

Reference #5 does support the assertion of medical use of Ti6Al4V (Ti-6Al-4V) alloy, albeit with strong qualifications, in stating:

Biocompatibility: Excellent, especially when direct contact with tissue or bone is required. Ti-6Al-4V's poor shear strength makes it undesirable for bone screws or plates. It also has poor surface wear properties and tends to seize when in sliding contact with itself and other metals. Surface treatments such as nitriding and oxidizing can improve the surface wear properties.

Because of concerns about the toxicity of the vanadium in Ti6Al4V (Ti-6Al-4V) alloy, Ti6Al7Nb (Ti-6Al-7Nb) alloy that replaced the vanadium with niobium was developed. See below 124.185.220.236 (talk) 18:09, 7 September 2012 (UTC)[reply]

Ti-6Al-7Nb titanium ally

Ti-6Al-7Nb is widely used in dentistry, in hip implants, and generally in human and in non-human animal medicine. Ti-6Al-7Nb was developed as a replacement for Ti-6Al-4V alloy because Ti-6Al-4V alloy contains cytotoxic vanadium. See page 1 of "The fatigue resistance of commercially pure titanium(grade II), titanium alloy (Ti6Al7Nb) and conventional cobalt-chromium cast clasps" (Inaugural-Dissertation zur Erlangung des Doktorgrades der Zahnheilkunde der Medizinschen Fakultät der Eberhard-Karls-Universität zu Tübingenvorgelegt von Mali Palanuwech, geb. 28.02.1974 aus München 2003).124.185.220.236 (talk) 18:09, 7 September 2012 (UTC)[reply]

Hello fellow Wikipedians,

I have just added archive links to one external link on Titanium alloy. Please take a moment to review my edit. If necessary, add {{cbignore}} after the link to keep me from modifying it. Alternatively, you can add {{nobots|deny=InternetArchiveBot}} to keep me off the page altogether. I made the following changes:

When you have finished reviewing my changes, please set the checked parameter below to true or failed to let others know (documentation at {{Sourcecheck}}).

This message was posted before February 2018. After February 2018, "External links modified" talk page sections are no longer generated or monitored by InternetArchiveBot. No special action is required regarding these talk page notices, other than regular verification using the archive tool instructions below. Editors have permission to delete these "External links modified" talk page sections if they want to de-clutter talk pages, but see the RfC before doing mass systematic removals. This message is updated dynamically through the template {{source check}} (last update: 5 June 2024).

  • If you have discovered URLs which were erroneously considered dead by the bot, you can report them with this tool.
  • If you found an error with any archives or the URLs themselves, you can fix them with this tool.

Cheers.—cyberbot IITalk to my owner:Online 03:55, 21 March 2016 (UTC)[reply]

Hello fellow Wikipedians,

I have just modified one external link on Titanium alloy. Please take a moment to review my edit. If you have any questions, or need the bot to ignore the links, or the page altogether, please visit this simple FaQ for additional information. I made the following changes:

When you have finished reviewing my changes, please set the checked parameter below to true or failed to let others know (documentation at {{Sourcecheck}}).

This message was posted before February 2018. After February 2018, "External links modified" talk page sections are no longer generated or monitored by InternetArchiveBot. No special action is required regarding these talk page notices, other than regular verification using the archive tool instructions below. Editors have permission to delete these "External links modified" talk page sections if they want to de-clutter talk pages, but see the RfC before doing mass systematic removals. This message is updated dynamically through the template {{source check}} (last update: 5 June 2024).

  • If you have discovered URLs which were erroneously considered dead by the bot, you can report them with this tool.
  • If you found an error with any archives or the URLs themselves, you can fix them with this tool.

Cheers.—InternetArchiveBot (Report bug) 00:33, 13 November 2016 (UTC)[reply]

Grade Four Titanium

There is a lengthy discusion of most of the ASTM titanium grades, but grade 4 (the second most common of the commerically pure titiamium grades, and a very common one at that) is missing. I don't know enough to fix this, but I feel it is important it is. Yellowy cake (talk) 21:32, 6 August 2018 (UTC)[reply]