Examine individual changes
Appearance
This page allows you to examine the variables generated by the Edit Filter for an individual change.
Variables generated for this change
Variable | Value |
---|---|
Name of the user account (user_name ) | '124.184.160.235' |
Page ID (page_id ) | '1007484' |
Page namespace (page_namespace ) | 0 |
Page title without namespace (page_title ) | 'Heat recovery ventilation' |
Full page title (page_prefixedtitle ) | 'Heat recovery ventilation' |
Action (action ) | 'edit' |
Edit summary/reason (summary ) | '' |
Whether or not the edit is marked as minor (no longer in use) (minor_edit ) | false |
Old page wikitext, before the edit (old_wikitext ) | '{{Unreferenced|date=May 2008}}
'''Heat recovery ventilation''' (also known as a '''heat exchanger''', '''air exchanger''' or '''air-to-air exchanger''') is a [[Ventilation (architecture)|ventilation]] system that employs a [[countercurrent exchange|counter-flow]] [[heat exchanger]] between the inbound and outbound air flow. HRV provide fresh air and improved climate control, while also saving energy by reducing the heating (or cooling) requirements.
[[Energy recovery ventilation|'''Energy recovery ventilators''']] (ERVs) are closely related, however ERVs also transfer the [[humidity]] level of the exhaust air to the intake air.
==Benefits==
As building efficiency is improved with [[Building insulation|insulation]] and [[weatherstripping]], buildings are intentionally made more air-tight, and consequently less well ventilated. Since all buildings require a source of fresh air, the need for HRVs has become obvious. While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency, since the building's [[HVAC]] systems must compensate. HRV technology offers an optimal solution: fresh air, better climate control and energy efficiency.
==Technology==
HRVs and ERVs can be stand-alone devices that operate independently, or they can be built-in, or added to existing HVAC systems. For a small building in which nearly every room has an exterior wall, then the HRV/ERV device can be small and provide ventilation for a single room. A larger building would require either many small units, or a large central unit. The only requirements for the building are an air supply, either directly from an exterior wall or ducted to one, and an energy supply for air circulation, such as wind energy or electricity for a fan. When used with 'central' HVAC systems, then the system would be of the 'forced-air' type.
==Air to air heat exchanger==
[[Image:Heat_exchanger.jpg|thumb|300px|]]
There are a number of heat exchangers used in HRV devices, as diagrammed to the right :
*cross flow heat exchanger up to 60% efficient (passive)
*counter current heat exchanger up to 99% efficient (passive)
*rotary heat exchanger (requires motor to turn wheel)
*heat pipes / thin multiple heat wires
The air coming into the heat exchanger should be at least 0°C. Otherwise humidity in the outgoing air may condense, freeze and block the heat exchanger.
A high enough incoming air temperature can also be achieved by recirculating some of the exhaust air (causing loss of air quality) when required, or by using a very small (1 kW) [[heat pump]] to warm the inlet air above freezing before it enters the HRV. (The 'cold' side of this heatpump is situated in the warm air outlet.)
==Earth-to-air heat exchanger==
[[Image:Passivhaus section en.jpg|thumb|300px|Heat recovery ventilation, often including an earth-to-air heat exchanger, is essential to achieve the German [[passivhaus]] standard]]
This can be done by an [[Ground-coupled heat exchanger|earth warming pipe]], usually about 30 m to 40 m long and 20 cm in diameter, typically buried about 1.5 m below ground level. In [[Germany]] and [[Austria]] this is a common configuration for earth to air heat exchangers.
In high humidity areas where internal condensation could lead to fungal/mould growth in the tube leading to contamination of the air, several measures exist to prevent this.
* Ensuring the tube drains of water.
* Regular cleaning
* Tubes with an imbedded bactericide coating such as silver ions (non-toxic for humans)
* Air filters F7 / EU7 (>0,4 micrometres) to traps mould (of a size between 2 & 20 micrometres).
* [[Ultraviolet_germicidal_irradiation#Air_purification|UV air purification]]
* Use a earth to "water" heat exchanger, see below.
The pipes may be either corrugated/slotted to enhance heat transfer and provide condensate drainage or smooth/solid to prevent gas/liquid transfer. This is highly site dependent.
That being stated, formal research indicates that Earth-Air Heat Exchangers reduce building ventilation air pollution. Rabindra (2004) states, “The Earth-Air Tunnel is found not to support the growth of bacteria and fungi; rather it is found to reduce the quantity of bacteria and fungi thus making the air safer for humans to inhale. It is therefore clear that the use of EAT (Earth-Air Tunnel) not only helps save the energy but also helps reduce the air pollution by reducing bacteria and fungi.” Likewise, Flueckiger (1999) in a study of twelve Earth-Air Heat Exchangers varying in design, pipe material, size and age, stated, “This study was performed because of concerns of potential microbial growth in the buried pipes of ground-coupled air systems. The results however demonstrate, that no harmful growth occurs and that the airborne concentrations of viable spores and bacteria, with few exceptions, even decreases after passage through the pipe-system”, and further stated, “Based on these investigations the operation of ground-coupled earth-to-air heat exchangers is acceptable as long as regular controls are undertaken and if appropriate cleaning facilities are available”.
An alternative to the earth to air heat exchanger is the "water" to earth heat exchanger. This is typically similar to a geothermal heat pump tubing embedded horizontally in the soil (or could be a vertical sonde) to a similar depth of the EAHX. It uses approximately double the length of pipe Ø 35 mm ie around 80 metres compared to an EAHX. A heat exchanger coil is placed before the air inlet of the HRV. Typically a brine liquid (heavily salted water) is used as the heat exchanger fluid.
In temperate climates in an energy efficient building, such as a [[passivhaus]], this is more than sufficient for comfort cooling during summer without resorting to an airconditioning system. In more extreme hot climates a very small air to air mico-heat pump in reverse (an air conditioner) on the air inlet after the HRV heat exchanger dumping heat to the air outlet after the heat exchanger will suffice.
==Bypass ==
At certain times of the year it is more thermally efficient to bypass the HRV heat exchanger or the earth to air heat exchanger (EAHX).
For example, during the winter, the earth at the depth of the earth to air heat exchanger is ordinarily much warmer than the air temperature. The air becomes warmed by the earth before reaching the air heat exchanger.
In the summer, the opposite is true. The air becomes cooled in the earth to air exchanger. But after passing through the EAHX, the air is warmed by the heat recovery ventilator using the warmth of the outgoing air. In this case, the HRV can have an internal bypass such that the inflowing air bypasses the heat exchanger maximising the cooling potential of the earth.
In autumn and spring there may be no thermal benefit from the EAHX, it may heat/cool the air too much and it will be better to use the external air directly. In this case there is a bypass such that the EAHX is disconnected and air taken directly from outside. A differential temperature sensor with a motorised valve can control its functioning.
==See also==
{{portal|Energy}}
{{Portal|Sustainable development|Sustainable development.svg}}
*[[Hot water heat recycling]]
*[[Green building]]
*[[Zero energy building]]
*[[:Category:Low-energy building]]
*[[Air conditioning#Health implications]]
==References==
{{refbegin}}
*1. Rabindra Nath B, Shailendra Kumar M, and Pawan Basnyat; Use of Earth Air Tunnel HVAC system in minimizing indoor air pollution; Air Quality Monitoring and Management, proceedings of Better Air Quality 2004.
*2. Flueckiger B, Monn C; Microbial investigations and allergen measurements in ground-coupled earth-to-air heat exchangers; AIVC 20th Conference and Indoor Air 99, the 8th International Conference on Indoor Air Quality and Climate, UK, Garston, BRE, 1999, proceedings, Edinburgh, Scotland, 8-13 August 1999, Volume 5.
{{refend}}
==External links==
*[http://www.seav.sustainability.vic.gov.au/manufacturing/sustainable_manufacturing/resource.asp?action=show_resource&resourcetype=2&resourceid=44#types Heat recovery in Industry]
* State of the art HRV for German [[passive house]]s
*[http://www.tangra.bg - "TANGRA" - Ventilation in Bulgaria]
*[http://www.rockenergy.co.uk/sites/construction/adCON_aa-low_carbon.php rockenergy: Highlands, UK]
*[http://sugarmtnfarm.com/blog/2008/09/earth-air-tubes.html Small home system using 4" earth air pipes - 7 year retrospective: Vermont, USA]
[[Category:Heating, ventilating, and air conditioning]]
[[Category:Low-energy building]]
[[Category:Energy conservation]]
[[Category:Residential heating]]
[[de:Wärmerückgewinnung]]
[[fr:Récupérateur sur air vicié]]' |
New page wikitext, after the edit (new_wikitext ) | '{{Unreferenced|date=May 2008}}
'''Heat recovery ventilation''' (also known as a '''heat exchanger''', '''air exchanger''' or '''air-to-air exchanger''') is a [[Ventilation (architecture)|ventilation]] system that employs a [[countercurrent exchange|counter-flow]] [[heat exchanger]] between the inbound and outbound air flow. HRV provide fresh air and improved climate control, while also saving energy by reducing the heating (or cooling) requirements.
[[Energy recovery ventilation|'''Energy recovery ventilators''']] (ERVs) are closely related, however ERVs also transfer the [[humidity]] level of the exhaust air to the intake air.
==Benefits==
As building efficiency is improved with [[Building insulation|insulation]] and [[weatherstripping]], buildings are intentionally made more air-tight, and consequently less well ventilated. Since all buildings require a source of fresh air, the need for HRVs has become obvious. While opening a window does provide ventilation, the building's heat and humidity will then be lost in the winter and gained in the summer, both of which are undesirable for the indoor climate and for energy efficiency, since the building's [[HVAC]] systems must compensate. HRV technology offers an optimal solution: fresh air, better climate control and energy efficiency.
==Technology==
HRVs and ERVs can be stand-alone devices that operate independently, or they can be built-in, or added to existing HVAC systems. For a small building in which nearly every room has an exterior wall, then the HRV/ERV device can be small and provide ventilation for a single room. A larger building would require either many small units, or a large central unit. The only requirements for the building are an air supply, either directly from an exterior wall or ducted to one, and an energy supply for air circulation, such as wind energy or electricity for a fan. When used with 'central' HVAC systems, then the system would be of the 'forced-air' type.
==Air to air heat exchanger==
[[Image:Heat_exchanger.jpg|thumb|300px|]]
There are a number of heat exchangers used in HRV devices, as diagrammed to the right :
*cross flow heat exchanger up to 60% efficient (passive)
*counter current heat exchanger up to 99% efficient (passive)
*rotary heat exchanger (requires motor to turn wheel)
*heat pipes / thin multiple heat wires
The air coming into the heat exchanger should be at least 0°C. Otherwise humidity in the outgoing air may condense, freeze and block the heat exchanger.
A high enough incoming air temperature can also be achieved by recirculating some of the exhaust air (causing loss of air quality) when required, or by using a very small (1 kW) [[heat pump]] to warm the inlet air above freezing before it enters the HRV. (The 'cold' side of this heatpump is situated in the warm air outlet.)
The pipes may be either corrugated/slotted to enhance heat transfer and provide condensate drainage or smooth/solid to prevent gas/liquid transfer. This is highly site dependent.
In temperate climates in an energy efficient building, such as a [[passivhaus]], this is more than sufficient for comfort cooling during summer without resorting to an airconditioning system. In more extreme hot climates a very small air to air mico-heat pump in reverse (an air conditioner) on the air inlet after the HRV heat exchanger dumping heat to the air outlet after the heat exchanger will suffice.' |
Whether or not the change was made through a Tor exit node (tor_exit_node ) | 0 |