Microrheology: Difference between revisions
No edit summary |
Rescuing 1 sources and tagging 0 as dead. #IABot (v1.6.2) |
||
Line 232: | Line 232: | ||
* [http://www.rsc.org/delivery/_ArticleLinking/DisplayHTMLArticleforfree.cfm?JournalCode=LC&Year=2009&ManuscriptID=b907992k&Iss=17 Review of microrheology in optical tweezers] |
* [http://www.rsc.org/delivery/_ArticleLinking/DisplayHTMLArticleforfree.cfm?JournalCode=LC&Year=2009&ManuscriptID=b907992k&Iss=17 Review of microrheology in optical tweezers] |
||
* [http://www.deas.harvard.edu/projects/weitzlab/papers/urheo_chapter.pdf Review on microrheology ] |
* [http://www.deas.harvard.edu/projects/weitzlab/papers/urheo_chapter.pdf Review on microrheology ] |
||
* [http://www.formulaction.com/microrheology_viscoelasticity.html Illustrated description of microrheology and a microrheology analysis, with movies ] |
* [https://archive.is/20111010061145/http://www.formulaction.com/microrheology_viscoelasticity.html Illustrated description of microrheology and a microrheology analysis, with movies ] |
||
* [http://www.lsinstruments.ch/technology/diffusing_wave_spectroscopy_dws/microrheology/ Microrheology Overview with Animations] |
* [http://www.lsinstruments.ch/technology/diffusing_wave_spectroscopy_dws/microrheology/ Microrheology Overview with Animations] |
||
Revision as of 09:56, 29 January 2018
Microrheology[1] is a technique used to measure the rheological properties of a medium, such as microviscosity, via the measurement of the trajectory of a flow tracer (a micrometre-sized particle). It is a new way of doing rheology, traditionally done using a rheometer. There are two types of microrheology: passive microrheology and active microrheology. Passive microrheology uses inherent thermal energy to move the tracers, whereas active microrheology uses externally applied forces, such as from a magnetic field or an optical tweezer, to do so. Microrheology can be further differentiated into 1- and 2-particle methods.[2] [3]
Passive microrheology
Passive microrheology uses the thermal energy (kT) to move the tracers, although recent evidence suggest that active random forces inside cells may instead move the tracers in a diffusive-like manner.[4] The trajectories of the tracers are measured optically either by microscopy or by diffusing-wave spectroscopy (DWS). From the mean squared displacement with respect to time (noted MSD or <Δr2> ), one can calculate the visco-elastic moduli G′(ω) and G″(ω) using the generalized Stokes–Einstein relation (GSER). Here is a view of the trajectory of a particle of micrometer size.
-
Typical trajectory of a Brownian particle (simulation)
-
Two examples of MSD: one for a purely viscous fluid (free diffusion) and one for a viscolelastic fluid (trapped by elastic network)
-
Animation of a particle in a polymer-like network
In a standard passive microrheology tests, the movement of dozens of tracers is tracked in a single video frame. The motivation is to average the movements of the tracers and calculate a robust MSD profile.
Observing the MSD for a wide range of integration time scales (or frequencies) gives information on the microstructure of the medium where are diffusing the tracers.
If the tracers are having a free diffusion in a purely viscous material, the MSD should grows linearly with sampling integration time:
.
If the tracers are moving in a spring-like fashion within a purely elastic material, the MSD should have no time dependence:
In most cases the tracers are presenting a sub-linear integration-time dependence, indicating the medium has intermediate viscoelastic properties. Of course, the slope changes in different time scales, as the nature of the response from the material is frequency dependent.
Microrheology is another way to do linear rheology. Since the force involved is very weak (order of 10−15 N), microrheology is guaranteed to be in the so-called linear region of the strain/stress relationship. It is also able to measure very small volumes (biological cell).
Given the complex viscoelastic modulus with G′(ω) the elastic (conservative) part and G″(ω) the viscous (dissipative) part and ω=2πf the pulsation. The GSER is as follows:
with
- : Laplace transform of G
- kB: Boltzmann constant
- T: temperature in kelvins
- s: the Laplace frequency
- a: the radius of the tracer
- : the Laplace transform of the mean squared displacement
A related method of passive microrheology involves the tracking positions of a particle at high frequency, often with a quadrant photodiode.[5] From the position, , the power spectrum, can be found, and then related to the real and imaginary parts of the response function, .[6] The response function leads directly to a calculation of the complex shear modulus, via:
Two Point Microrheology[7]
There could be many artifacts that change the values measured by the passive microrheology tests, resulting in a disagreement between microrheology and normal rheology. These artifacts include tracer-matrix interactions, tracer-matrix size mismatch and more.
A different microrheological approach studies the cross-correlation of two tracers in the same sample. In practice, instead of measuring the MSD - , movements of two distinct particles are measured - . Calculating the G(ω) of the medium between the tracers follows:
Notice this equation does not depend on a, but instead in depends on R - the distance between the tracers (assuming R>>a).
Some studies has shown that this method is better in coming to agreement with standard rheological measurements (in the relevant frequencies and materials)
Active microrheology
Active microrheology may use a magnetic field ,[8][9][10][7][11] [12] optical tweezers[13] [14] [15] [16][17] and Atomic force microscope[18] to apply a force on the tracer and then find the stress/strain relation.
The force applied is a sinusoidal force with amplitude A and frequency ω -
The response of the tracer is a factor of the matrix visco-elastic nature. If a matrix is totally elastic (a solid), the response to the acting force should be immediate and the tracers should be observed moving by-
.
with .
On the other hand, if the matrix is totally viscus (a liquid), there should be a phase shift of between the strain and the stress -
in reality, as most materials are visco-elastic, the phase shift observed is .
When φ>45 the matrix is considered mostly in its "viscus domain" and when φ<45 the matrix is considered mostly in its "elastic domain".
Given a measured response phase shift φ (sometimes noted as δ), this ratio applies:
Similar response phase analysis is used in regular rheology testing.
More recently, it has been developed into Force spectrum microscopy to measure contributions of random active motor proteins to diffusive motion in the cytoskeleton.[4]
References
- ^
Mason, Thomas G.; Weitz, David A. (1995). "Optical Measurements of Frequency-Dependent Linear Viscoelastic Moduli of Complex Fluids". Physical Review Letters. 74: 7. Bibcode:1995PhRvL..74.1250M. doi:10.1103/physrevlett.74.1250. PMID 10058972.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^
Crocker, John C.; Valentine, M. T.; Weeks, Eric R.; Gisler, T.; et al. (2000). "Two-Point Microrheology of Inhomogeneous Soft Materials". Physical Review Letters. 85 (4): 888–891. Bibcode:2000PhRvL..85..888C. doi:10.1103/PhysRevLett.85.888. PMID 10991424.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^
Levine, Alex J.; Lubensky, T. C. (2000). "One- and Two-Particle Microrheology". Physical Review Letters. 85 (8): 1774–1777. arXiv:cond-mat/0004103. Bibcode:2000PhRvL..85.1774L. doi:10.1103/PhysRevLett.85.1774.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^ a b Guo, Ming; et al. (2014). "Probing the Stochastic, Motor-Driven Properties of the Cytoplasm Using Force Spectrum Microscopy". Cell. 158: 822–832. doi:10.1016/j.cell.2014.06.051. PMC 4183065. PMID 25126787.
- ^
Schnurr, B.; Gittes, F.; MacKintosh, F. C.; Schmidt, C. F. (1997). "Determining Microscopic Viscoelasticity in Flexible and Semiflexible Polymer Networks from Thermal Fluctuations". Macromolecules. 30 (25): 7781–7792. arXiv:cond-mat/9709231. Bibcode:1997MaMol..30.7781S. doi:10.1021/ma970555n.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^
Gittes, F.; Schnurr, B.; Olmsted, P. D.; MacKintosh, F. C.; et al. (1997). "Determining Microscopic Viscoelasticity in Flexible and Semiflexible Polymer Networks from Thermal Fluctuations". Physical Review Letters. 79 (17): 3286–3289. arXiv:cond-mat/9709228. Bibcode:1997PhRvL..79.3286G. doi:10.1103/PhysRevLett.79.3286.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^ a b Weitz, D. A., John C. Crocker (2000). "Two-Point Microrheology of Inhomogeneous Soft Materials". Phys. Rev. Lett. 85: 888–891. Bibcode:2000PhRvL..85..888C. doi:10.1103/PhysRevLett.85.888.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^ A.R. Bausch; et al. (1999). "Measurement of local viscoelasticity and forces in living cells by magnetic tweezers". Biophysical Journal. 76 (1 Pt 1): 573–9. Bibcode:1999BpJ....76..573B. doi:10.1016/S0006-3495(99)77225-5. PMC 1302547. PMID 9876170.
- ^ K.S. Zaner; P.A. Valberg (1989). "Viscoelasticity of F-actin measured with magnetic microparticles". Journal of Cell Biology. 109 (5): 2233–43. doi:10.1083/jcb.109.5.2233. PMC 2115855. PMID 2808527.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^ F.Ziemann; J. Radler; E. Sackmann (1994). "Local measurements of viscoelastic moduli of entangled actin networks using an oscillating magnetic bead micro-rheometer". Biophysical Journal. 66 (6): 2210–6. Bibcode:1994BpJ....66.2210Z. doi:10.1016/S0006-3495(94)81017-3. PMC 1275947. PMID 8075354.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^ F. Amblard; et al. (1996). "Subdiffusion and Anomalous Local Viscoelasticity in Actin Networks". Physical Review Letters. 77 (21): 4470–4473. Bibcode:1996PhRvL..77.4470A. doi:10.1103/PhysRevLett.77.4470. PMID 10062546.
- ^ Manlio Tassieri; et al. (2010). "Analysis of the linear viscoelasticity of polyelectrolytes by magnetic microrheometry—Pulsed creep experiments and the one particle response". Journal of Rheology. 54: 117–131. doi:10.1122/1.3266946.
- ^ E. Helfer; et al. (2000). "Microrheology of Biopolymer-Membrane Complexes". Physical Review Letters. 85 (2): 457–60. Bibcode:2000PhRvL..85..457H. doi:10.1103/PhysRevLett.85.457. PMID 10991307.
- ^ Manlio Tassieri; et al. (2009). "Measuring storage and loss moduli using optical tweezers: Broadband microrheology". Phys. Rev. E. 81: 026308. doi:10.1103/PhysRevE.81.026308.
- ^ Daryl Preece; et al. (2011). "Optical tweezers: wideband microrheology". Journal of Optics. 13 (11): 044022. doi:10.1088/2040-8978/13/4/044022.
- ^ Manlio Tassieri; et al. (2012). "Microrheology with optical tweezers: data analysis". New Journal of Physics. 14 (11): 115032. Bibcode:2012NJPh...14k5032T. doi:10.1088/1367-2630/14/11/115032.
- ^ David Engström; Michael C.M. Varney; Martin Persson; Rahul P. Trivedi; et al. (2012). "Unconventional structure-assisted optical manipulation of high-index nanowires in liquid crystals". Optics Express. 20 (7): 7741–7748. Bibcode:2012OExpr..20.7741E. doi:10.1364/OE.20.007741.
{{cite journal}}
: Unknown parameter|last-author-amp=
ignored (|name-list-style=
suggested) (help) - ^ Rigato, Annafrancesca; Miyagi, Atsushi; Scheuring, Simon; Rico, Felix (2017-05-01). "High-frequency microrheology reveals cytoskeleton dynamics in living cells". Nature Physics. advance online publication. doi:10.1038/nphys4104. ISSN 1745-2481.